displayed on the LCD screen, do not attempt to start the unit. Contact your dealer and schedule a
maintenance check.
5. Use the start button on the control panel to crank the generator.
Page 10-60
!
!
C
C
A
A
U
U
T
T
I
I
O
O
N
N
If the generator does not start within the first three attempts, turn the panel off and contact your
dealer prior to further use. Failure to do so, will result in significant damage to the generator.
1. Once the generator is running, engage the “SHIP POWER” circuit breaker and verify that the “REVERSE
POLARITY” indicator is not lit. If it is not lit proceed to step 7, however, if the red LED indicator is lit,
immediately turn “OFF” the “SHIP POWER” breaker and shut down the generator. Notify your dealer
regarding the issue and have a trained electrician inspect your boat to determine if any damage has been
sustained by the electrical system.
2. You may now engage the AC accessory breakers.
!
!
C
C
A
A
U
U
T
T
I
I
O
O
N
N
For safety reasons, the seacock must be closed after the generator has been switched off. It should
be re-opened before starting the generator.
Routine maintenance should be performed on this unit using the guidelines established by Fischer Panda™. Failure to
comply with these guidelines will result in loss of warranty coverage and creates the potential for property damage or
personal injury.
10.1.22 Climate Control Unit
The heating/air conditioning unit is mounted under the port lounge seat. It can be accessed by removing the removing
the bulkhead located above the quarter berth on the port side of the cabin.. The filter control panel are located in this
bulkhead. Follow these startup guidelines before each use of the unit:
1. Verify that the seacock located in the port aft bilge compartment is open.
2. Using the guidelines provided, energize the AC panel using the generator of shore power connection and
engage the corresponding circuit breaker.
3. Using the control panel, energize the climate control unit and select the operating mode and desired
temperature using the selection tools. This will engage the raw water pump located in the port aft rigging
compartment.
4. Once the unit is running, inspect for water flow through the system by checking the thru-hull located on the
port sponson (see Thru-Hull drawing page 23). If water is not flowing, shut down the unit immediately to
prevent damage. Then have your dealer inspect the system.
Similar to a residential system, the filter units must be replaced at regular intervals to ensure proper operation. Use the
manual provided in your “Owner’s Packet” to obtain requirements for service, and to get recommendations on usage.
10.2 M
AXIMUM
H
ORSEPOWER
R
ATING
: T
WIN
300 4-S
TROKE
HP (600 HP
TOTAL
)
Summary of Contents for 2013 320EC
Page 1: ...2013 OWNER S MANUAL ...
Page 12: ...2013 World Cat 320EC Owners Manual Page 3 11 ...
Page 13: ...2013 World Cat 320EC Owners Manual 3 2 STANDARD EQUIPMENT ON ALL WORLD CATS Page 3 12 ...
Page 14: ...2013 World Cat 320EC Owners Manual 3 3 320EC OPTIONS LIST Page 3 13 ...
Page 35: ...2013 World Cat 320EC Owners Manual 6 10 TRADITIONAL ROCKER SWITCH DIAGRAM Page 6 34 ...
Page 44: ...2013 World Cat 320EC Owners Manual Page 7 43 ...
Page 45: ...2013 World Cat 320EC Owners Manual Page 7 44 ...
Page 46: ...2013 World Cat 320EC Owners Manual Page 7 45 ...
Page 47: ...2013 World Cat 320EC Owners Manual Page 7 46 ...
Page 49: ...2013 World Cat 320EC Owners Manual Chapter 8 HURRICANE PREPAREDNESS Page 8 48 ...
Page 50: ...2013 World Cat 320EC Owners Manual Page 8 49 ...
Page 51: ...2013 World Cat 320EC Owners Manual Page 8 50 ...
Page 72: ...2013 World Cat 320EC Owners Manual 11 2 10 Thru hull Diagram Page 11 71 ...