background image

6. SYSTEM ASSEMBLY

Figure 6.4: Output pin scheme.

6.1.4 Analog Outputs

You can use 7 Analog Outputs of your SMARTIS with M12 8‐pin cable. Each Analog Output can be set as voltage
or current loop:

Voltage

±

12V

• 0V ‐ 12V

• 0V ‐ 6V

Current

±

24mA

• 4mA ‐ 24mA

You can see the Analog Outputs connector pinout in the Figure 6.5a.

(a) Connector pinout.

Contact

Function

Color

1

A0+

White

2

A0‐

Brown

3

A1+

Green

4

A1‐

Yellow

5

A2+

Gray

6

A2‐

Pink

7

A3+

Blue

8

A3‐

Red

(b)

Analog

outputs

wire

coloring.

E‐mail and Web

[email protected]
www.workswell.eu

Mobile:

+420 725 877 063

ID:

Reg. No.: 29048575
VAT No.: CZ29048575

Headquarters

Libocka 653/51b
Prague, Czech Republic

Version 210127 EN, 27

th

Jan, 2021

All pictures are only for illustration.
Real values may vary.

11

Summary of Contents for SMARTIS

Page 1: ...WORKSWELL SMARTIS USER MANUAL FW Version 1 0 0 Release date 27th January 2021 Version 210127 EN...

Page 2: ...1 1 Power Supply 9 6 1 2 Digital Triggers 9 6 1 3 Digital Outputs 10 6 1 4 Analog Outputs 11 6 2 Mounting the system 12 7 General usage overview 13 7 1 Controlling SMARTIS 13 7 1 1 Web server 13 7 1...

Page 3: ...ngs panel 29 9 5 5 Edit ROI panel 29 9 5 6 Sequence panel 29 9 6 Table 31 9 6 1 Statistic 31 9 6 2 Value 31 9 6 3 Extreme 31 9 6 4 Operator 31 9 6 5 Extreme val 31 9 6 6 Digital 32 9 6 7 Analog 32 9 6...

Page 4: ...warm up 51 16 2 Non uniformity correction 51 17 Maintanance 52 17 1 Cleaning the SMARTIS head and cables 52 17 2 Cleaning the infrared lens 52 18 Troubleshoot 53 18 1 Turning ON 53 18 2 Connection err...

Page 5: ...eriod Nobody but Workswell s r o is allowed to open or modify such product Workswell s r o has no other obligation or liability for defects than those set forth above No other warranty is expressed or...

Page 6: ...contact your dealer search Workswell s r o website at https workswell cz termokamera smartis log in and send an email to support workswell eu E mail and Web info workswell eu www workswell eu Mobile 4...

Page 7: ...e is not such answer please log in and send an email on support workswell eu 3 3 Updates The primary aim of Workswell s r o company is to supply their products in a way to meet the current needs of it...

Page 8: ...ug the camera into the same power source as drone s motors Do not use the Workswell SMARTIS system in temperatures higher than 50 C 122 F High temperatures can cause damage to the camera Do not use th...

Page 9: ...contact and version numbering E mail and Web info workswell eu www workswell eu Mobile 420 725 877 063 ID Reg No 29048575 VAT No CZ29048575 Headquarters Libocka 653 51b Prague Czech Republic Version 2...

Page 10: ...tor pinout Contact Function Color 1 VCC Brown 2 VCC White 3 GND Black 4 GND Blue 5 NC Gray b Power supply wire coloring Note Exceeding the input power range may cause damage to the SMARTIS 6 1 2 Digit...

Page 11: ...ou can see the Digital Outputs connector pinout in the Figure 6 3a and output s schematics and example circuit in the Figure 6 4 a Connector pinout Contact Function Color 1 D0 White 2 D1 Brown 3 D2 Gr...

Page 12: ...g Outputs connector pinout in the Figure 6 5a a Connector pinout Contact Function Color 1 A0 White 2 A0 Brown 3 A1 Green 4 A1 Yellow 5 A2 Gray 6 A2 Pink 7 A3 Blue 8 A3 Red b Analog outputs wire colori...

Page 13: ...ings and dimensions E mail and Web info workswell eu www workswell eu Mobile 420 725 877 063 ID Reg No 29048575 VAT No CZ29048575 Headquarters Libocka 653 51b Prague Czech Republic Version 210127 EN 2...

Page 14: ...s up The web server is available on the standard web port 80 7 1 2 Login control The inner logic of SMARTIS does not allow more users to log into the web server simultaneously This should prevent unex...

Page 15: ...e can select some if his products and starts or stops measurement sessions Please refer to chapter 10 for further details 7 2 Products overview For the broadest range of usage administrator can create...

Page 16: ...ct settings It will do individual measurements and evaluate the results Each single measurement can consist of data collecting from incoming thermal images The SMARTIS will continue a measurement unti...

Page 17: ...the SMARTS settings mode select the Admin user For opening the operator mode select appropriate user from the combo box menu 2 Type in the correct password 3 Press Log In Figure 8 1 Main log in scree...

Page 18: ...2 Stop measurement with the Admin password and log to the main log in screen Figure 8 2 Main log in screen measurement in progress E mail and Web info workswell eu www workswell eu Mobile 420 725 877...

Page 19: ...ttings In this part you can see Serial number Camera resolution Firmware version You can set Units Celsius Fahrenheit Kelvin Language English Czech You can upload update file with new firmware version...

Page 20: ...rk button After that SMARTIS will reboot and start with the new IP address You have to change the address in your web browser to the new one for connecting to the SMARTIS Figure 9 2 System Network set...

Page 21: ...sired user from the combo box 2 Type in the new password 3 Type in the password again for confirmation 4 Press the Edit button For deleting an user 1 Select the desired user from the combo box 2 Press...

Page 22: ...ory erase Log files select Auto erase Log files If this option is set old log files and images are erased when the memory is full Figure 9 5 System Log Files settings E mail and Web info workswell eu...

Page 23: ...rough all of the settings tabs and set up your product If you want to delete an existing product select it from the table below and click the Delete button For copying a product with all of its settin...

Page 24: ...triggered mode you can select one of the two trigger options 1 Latch trigger One trigger signal measurement during high level of the signal 2 Start and Stop Two trigger signals one for starting and o...

Page 25: ...find more information about the Ethernet commands in the chapter 11 9 4 1 Frame Measurement and Evaluation In this mode you can start the measurement with one trigger The measurement stops after defi...

Page 26: ...rs start with one Start trigger and with one Stop trigger 2 One trigger start with Latch trigger in logical high state and stop with Latch trigger in logical low state When the measurement is active S...

Page 27: ...esis Save Image saves image with log file which can be downloaded and evaluated later Figure 9 13 Non Trigger Evaluation example E mail and Web info workswell eu www workswell eu Mobile 420 725 877 06...

Page 28: ...n the Rectangle symbol and then anywhere into the image you want to place the first Rectangle point Then click the second Rectangle point Circle click on the Circle symbol and then anywhere into the i...

Page 29: ...ave selected the manual temperature range you can set the appropriate Max Min limits You can select one of several different temperature palettes for your camera image by clicking anywhere in the pale...

Page 30: ...u can also set ROI name duplicate ROI duplicates selected ROI delete ROI deletes selected ROI 9 5 6 Sequence panel You can record a video sequence by clicking the Start button or by switching ON your...

Page 31: ...ettings panels E mail and Web info workswell eu www workswell eu Mobile 420 725 877 063 ID Reg No 29048575 VAT No CZ29048575 Headquarters Libocka 653 51b Prague Czech Republic Version 210127 EN 27th J...

Page 32: ...Extreme The statistic value is calculated for each frame In case of Frame or Start Stop mode the measurement can consist of several frames and thus several statistical results for each ROI The extreme...

Page 33: ...0 0 0 1 0 1 0 1 0 1 1 0 1 0 0 1 1 0 1 1 1 0 1 0 Table 9 1 Summarizing table for boolean logic 1 is positive result and 0 is negative This is the short summary of boolean operators AND Positive only if...

Page 34: ...the appropriate range that the output can achieve T MIN Minimum temperature any temperature lower than this value will be represented as the lower limit of the output range T MAX Minimum temperature...

Page 35: ...t the length for the signal pulse in milliseconds Edge Select the edge of a signal Either the edge is rising or falling Rising edge has the nonactive state at zero and the signal is a change between z...

Page 36: ...Indicators The most important ROI and their values or result can be displayed in special panel in operator mode Just select the number of numeric operators the ROI numbers and corresponding indicator...

Page 37: ...Save changes and log out Discard Log Off Discard changes and log out Save Start Measurement Select user you want to log in Figure 9 22 Finish window E mail and Web info workswell eu www workswell eu...

Page 38: ...he basic layout of Operator Mode screen is the same for every measurement type Figure 10 1 Operator Mode Basic layout 10 1 1 Individual parts Product selection The products can be selected from combo...

Page 39: ...highlighted red Figure 10 3 ROI Table SMARTIS information and numeric indicators Some basic information about the SMARTIS and measurement can be found int the tab SMARTIS STATUS The selected numeric i...

Page 40: ...ph The selected ROI statistic result values are displayed in the graph The x axis unit represents frames and y axis unit represents either the degrees Celsius degrees Fahrenheit or Kelvin The graph sh...

Page 41: ...inputs b Digital outputs c Analog outputs Figure 10 7 Digital inputs outputs and analog outputs 10 1 2 Measurement types differences Each measurement type differs in the displayed thermocamera image g...

Page 42: ...ce between the critical value and ROI frame statistic among all ROIs This is the most important frame for evaluating fail states The graph shows all the selected ROI statistic results for all frames i...

Page 43: ...he Ethernet connection fails after reconnecting to the web server the user is informed about the ongoing measurement and only the operator who started the measurement or administrator can stop the mea...

Page 44: ...most common answers are OK in case of success and ERR in case of error When parameters are given or returned they are divided with one space Check connection Command used for checking the connection...

Page 45: ...on Stops measurement session Request SOM Answer OK Get ROI measured value Sends selected ROI current frame statistic value Argument specifies the ROI order number Request GRM 5 Answer 25 54 Get ROI re...

Page 46: ...four types of digital triggers each has different message as in example Latch trigger also need to specify the length in milliseconds Request TRG LATCH 1000 TRG START TRG STOP TRG CIC Answer OK E mai...

Page 47: ...strator and users can copy files from FTP server but only administrator can delete file on the FTP server 12 1 1 Restrictions and warnings The FTP server is available even during measurements when SMA...

Page 48: ...ort of the browser The server was tested with the Filezilla software https filezilla project org E mail and Web info workswell eu www workswell eu Mobile 420 725 877 063 ID Reg No 29048575 VAT No CZ29...

Page 49: ...file selection The file will be uploaded to SMARTIS and checked for errors which can take several minutes When ready window with the result information shows up To install the update system will be re...

Page 50: ...CorePlayer Figure 14 1 Workswell CorePlayer Workswell CorePlayer allows the user to Change measurement parameters emissivity Change temperature range colour palette Use multiple isotherms Use measure...

Page 51: ...rature range from 30 C to 60 C Humidity 5 95 noncondensing Maximum irradiance 100W cm2 If you use the product in conflict with these conditions damage to the Workswell SMARTIS system can occur E mail...

Page 52: ...infrared camera warm before using it 16 2 Non uniformity correction Infrared camera needs to be periodically calibrated in order to get reasonable measurement accuracy This process is called Non unif...

Page 53: ...on wool in the liquid 2 Twist the cotton wool to remove excess liquid 3 Clean the lens one time only and discard the cotton wool Warning Make sure that you read all applicable MSDS Material Safety Dat...

Page 54: ...ress 18 3 Factory Default If you want to reset the SMARTIS to its Factory default state press and hold the RESET button for more than 30 seconds Note All of your saved data settings and FW updates wil...

Page 55: ...he current version on https workswell cz termokamera smartis E mail and Web info workswell eu www workswell eu Mobile 420 725 877 063 ID Reg No 29048575 VAT No CZ29048575 Headquarters Libocka 653 51b...

Page 56: ...workswell cz Headquarters Libocka 653 51b 160 00 Prague6 Czech Republic Branches Meziricska 100 756 61 Roznov p R Czech Republic Company contact details Mobile 420 725 877 063 E mail info workswell e...

Reviews: