background image

 

 

3  Operation 

3.1    On/Off key 

Hold the key 2 seconds.  All display segments will light. The 
terminal will show software part number [

178037

] [

L 1.00

]. 

Then the terminal will show the normal weight. 
In normal display state, Hold this key 2 seconds, the terminal 
will show [ 

-OFF-

 ], then power off. 

 

3.2    Zero 

Zero the scale. 

 
 

3.3  Tare 

Tare the scale, the display will change to Net mode. 
 

 

3.4  Clear 

Clear the tare, the display will go back to gross mode. 

 
 

4  Loading type and rated weight 

4.1 

The best loading type is when the cargo gravity center is in the middle of the 

truck forks. The rated weight must be reduced when the cargo gravity center is 
not in the middle of the truck forks. The rated weight is shown on the label. 

4.2 

See  Fig 4. When the hand pallet truck with scale is used to weigh or carry 

cargo, the handle knob (8)  should be moved to the drop position  then  let the 
truck forks down to desired  position. When the hand pallet truck with scale 
lifts cargo, the handle knob (8) should be moved to the lift position then pump 
the hand grip and lift the truck forks to desired position. 

4.3 

During the process of moving cargo, the handle knob (8) should be on the free 

position. 

4.4

 

When parking the truck or before lifting cargo, make sure the parking brake is 

engaged. The brake (12) and brake lock (13) should be on. 

 

 

5  Oil 

5.1   

The capacity of oil needed for the oil pump is about 250ml (or 0.25kg/0.55lbs). 

According to the ISO oil criteria, the choice of oil is 32# when the 
environment temperature is  23~104F / -5~40

.  The choice of oil is low 

temperature oil when the environment temperature is -31~23F / -35~-5

5.2 

Disposition of waste oil: Dispose the waste oil in terms of relative laws. 

  

  

0

  

T

  

C

Reviews: