5
3 Operation
3.1 On/Off key
Hold the key 2 seconds. All display segments will light. The
terminal will show software part number [
178037
] [
L 1.00
].
Then the terminal will show the normal weight.
In normal display state, Hold this key 2 seconds, the terminal
will show [
-OFF-
], then power off.
3.2 Zero
Zero the scale.
3.3 Tare
Tare the scale, the display will change to Net mode.
3.4 Clear
Clear the tare, the display will go back to gross mode.
4 Loading type and rated weight
4.1
The best loading type is when the cargo gravity center is in the middle of the
truck forks. The rated weight must be reduced when the cargo gravity center is
not in the middle of the truck forks. The rated weight is shown on the label.
4.2
See Fig 4. When the hand pallet truck with scale is used to weigh or carry
cargo, the handle knob (8) should be moved to the drop position then let the
truck forks down to desired position. When the hand pallet truck with scale
lifts cargo, the handle knob (8) should be moved to the lift position then pump
the hand grip and lift the truck forks to desired position.
4.3
During the process of moving cargo, the handle knob (8) should be on the free
position.
4.4
When parking the truck or before lifting cargo, make sure the parking brake is
engaged. The brake (12) and brake lock (13) should be on.
5 Oil
5.1
The capacity of oil needed for the oil pump is about 250ml (or 0.25kg/0.55lbs).
According to the ISO oil criteria, the choice of oil is 32# when the
environment temperature is 23~104F / -5~40
℃
. The choice of oil is low
temperature oil when the environment temperature is -31~23F / -35~-5
℃
.
5.2
Disposition of waste oil: Dispose the waste oil in terms of relative laws.
0
T
C