DMX starting address
Dip Switch 1 address equals 1
Dip Switch 2 address equals 2
Dip Switch 3 address equals 4
Dip Switch 4 address equals 8
Dip Switch 5 address equals 16
Dip Switch 6 address equals 32
Dip Switch 7 address equals 64
Dip Switch 8 address equals 128
Dip Switch 9 address equals 256
1,2,4
3,4
1,3,4
2,3,4
1,2,3,4
1
2
1,2
3
1,3
2,3
1,2,3
4
1,4
START
SWITCHES ON
SWITCHES ON
2,4
CH#
START
CH#
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
..
..
..
..
..
..
ON
OFF
1=
0=
1,2,3,4,5,6,7,8,9
..
For example:
Setting DMX address for 21.
Flip switches1,3,&5 to the
“
"position
ON
Dipswitches#
Value
1=1
3=4
5=16
=21
1 2 3 4 5 6 7 8 9 10
11 12
ON
0=OFF
1=
DMX Mode
In this mode, dip-switch 10 is flipped to
ON
. Use the dip 1-9 to set the starting DMX address. The unit
needs one channel for control. The channel value determinates the volume for both channels at same time.
NOTE
: If the value is setting between 0%-10%, the unit is in Standby mode.
NOTE:
This channel controls the volume, therefore this value will indicate the percentage. For example, a DMX
value of 255 corresponds to 100% volume level, 127 corresponds to about 50%, etc.
Rs485 Mode
In this mode, dip-switch 10 is flipped to
OFF
. It has priority over analog control. The accepted command sentences
are:
#nnnVOL:INC=XX;CH=aa;\
Volume control
Where:
-
nnn
is the device address (between 1 to 511). If nnn=000 it is a broadcast.
-
XX
is the quantity of steps (between 1 to 255) to increase o reduce the volume (depending on the previous
sign + or -).
-
aa
can be CH1, CH2 or MASTER (for alter both channels)
#nnnSTB:\
The device turns to STANDBY mode. In this operation mode the consumption is minimum.
#nnnNOSTB:\
The device will return to normal operation.
#nnnAL:\
The device turns to ALARM condition. In this mode the volume will change to maximum and the analog control
will be disabled.
##nnnNOAL:\
The device leaves ALARM condition, returning to normal condition with the previous volume level.
0-10 V Control
This mode is always activated. When the value of the control signal varies, SLA take it this value as new volume
value. The value will be as reference until:
a) If the controller is operating in DMX mode and the DMX channel value changes.
b) If the controller is operating in RS485 mode and it receives a command will affect the volume.
NOTE
: Analog control will affect both channels at the same time.
NOTE
: Analog control will be disable if the unit receive an ALARM command through RS485 interface.
EN
10
ON
0=OFF
1=
NOTE:
For a better
understanding. the
square in white color
is considered the switch
in all pictures of this
user manual
OPERATION
INDICATORS
The status LED indicates:
a) ON: Normal Operation b) Blink: Standby Mode
SLA Series (SLA 50 - SLA 300) User Manual/Manual de Instrucciones Pag 2