1 2 3 4 5 6 7 8 9 10

DMX starting address

Dip Switch 1 address equals 1
Dip Switch 2 address equals 2
Dip Switch 3 address equals 4
Dip Switch 4 address equals 8

Dip Switch 5 address equals 16
Dip Switch 6 address equals 32
Dip Switch 7 address equals 64

Dip Switch 8 address equals 128
Dip Switch 9 address equals 256

1,2,4

3,4

1,3,4
2,3,4

1,2,3,4

1
2

1,2

3

1,3
2,3

1,2,3

4

1,4

START

SWITCHES ON

SWITCHES ON

2,4

CH#

START

CH#

1
2
3
4
5
6
7

8
9

10

11

12
13
14
15

..

..

..

..

..

..

ON

OFF

1=

0=

1,2,3,4,5,6,7,8,9

..

For example:

Setting DMX address for 21.
Flip switches1,3,&5 to the

"position

ON

Dipswitches#

Value

1=1
3=4
5=16

=21

1 2 3 4 5 6 7 8 9 10

11 12

ON

0=OFF

1=

DMX Mode

In this mode, dip-switch 10 is flipped to 

ON

. Use the dip 1-9 to set the starting DMX address. The unit

needs one channel for control. The channel value determinates the volume for both channels at same time.

NOTE

: If the value is setting between 0%-10%, the unit is in Standby mode.

NOTE:

 This channel controls the volume, therefore this value will indicate the percentage. For example, a DMX 

value of 255 corresponds to 100% volume level, 127 corresponds to about 50%, etc.

Rs485 Mode

In this mode, dip-switch 10 is flipped to 

OFF

. It has priority over analog control. The accepted command sentences 

are:

#nnnVOL:INC=XX;CH=aa;\

Volume control
Where:
    - 

nnn

 is the device address (between 1 to 511). If nnn=000 it is a broadcast.

    - 

XX

 is the quantity of steps (between 1 to 255) to increase o reduce the volume (depending on the previous 

      sign + or -).
    - 

aa

 can be CH1, CH2 or MASTER (for alter both channels)

#nnnSTB:\

The device turns to STANDBY mode. In this operation mode the consumption is minimum.

#nnnNOSTB:\

The device will return to normal operation.

#nnnAL:\

The device turns to ALARM condition. In this mode the volume will change to maximum and the analog control 
will be disabled.

##nnnNOAL:\ 

The device leaves ALARM condition, returning to normal condition with the previous volume level.

0-10 V Control

This mode is always activated. When the value of the control signal varies, SLA take it this value as new volume 
value. The value will be as reference until:
   a) If the controller is operating in DMX mode and the DMX channel value changes.
   b) If the controller is operating in RS485 mode and it receives a command will affect the volume.

NOTE

: Analog control will affect both channels at the same time.

NOTE

: Analog control will be disable if the unit receive an ALARM command through RS485 interface.

EN

10

ON

0=OFF

1=

NOTE:

 For a better 

understanding. the 
square in white color 
is considered the switch
in all pictures of this
user manual

OPERATION

INDICATORS

The status LED indicates:
                   a) ON: Normal Operation                    b) Blink: Standby Mode

SLA Series (SLA 50 - SLA 300)       User Manual/Manual de Instrucciones                          Pag 2

Summary of Contents for SLA SERIES

Page 1: ...Ver 12 07 01 User Manual Instrucciones de Usuario SLA SERIES...

Page 2: ...REVERSE THE POLARITY TECHNICAL SPECIFICATIONS CONNECTIONS EN Output Power 25W 25W SLA 50 150W 150W SLA 300 Sensitivity Vrms 1V Unbal 500 mV Bal 1V Unbal 500 mV Bal Power Supply 22 28V DC Tip 24V DC 2...

Page 3: ...INC XX CH aa Volume control Where nnn is the device address between 1 to 511 If nnn 000 it is a broadcast XX is the quantity of steps between 1 to 255 to increase o reduce the volume depending on the...

Page 4: ...IN Channel L AUDIO IN Channel R DMX Controller or RS485 ASCII Commands nnnMUTx It pass to MUTE condition the channel marked by x 1 or 2 If x does not write both channels will pass to MUTE condition n...

Page 5: ...LIMENTACI N NO INVIERTA LA POLARIDAD ESPECIFICACIONES TECNICAS CONEXIONES ES SLA Series SLA 50 SLA 300 User Manual Manual de Instrucciones Pag 4 Conector euroblock 2 pin y Conector euroblock 2 pin y C...

Page 6: ...e al de control var a SLA toma este valor como nuevo valor de volumen El valor ser la referencia hasta que a Si el controlador est operando en modo DMX y el valor del canal DMX var a b Si el controlad...

Page 7: ...asa a condici n MUTE el canal marcado en x 1 o2 Si no se escribe x ambos canales pasar n a la condici n MUTE nnnUMUTx El canal marcado como x abandonar la condici n MUTE Si no se escribe x ambos canal...

Page 8: ...point for the recycling of electrical an electronic equipment By ensuring this product is disposed of correctly you will help prevent potential negative consequences for the environment and human hea...

Reviews: