WorkPro PA 120 USB/R User Manual Download Page 7

                                            PAGE 5

User Manual

       PA 120 USB/R

 / Manual de uso

1

4

2

5

3

 

1

4

2

5

3

 

2

1

3

Mains Connection (33)

The supply transformer has been designed for use on either 115V AC or 230 V AC, selected by slide
switch on the rear panel 

(32)

. The amplifier is factory set at 230 V AC mains voltage.

Battery Connection (24V DC) (15)

         

When using externaI batteries, the amplifier must be earthed via the screw terminal due to the high

         

voltages present. This is necessary to ensure the case is earthed and ensure electrical stability.

Input Connections

Mics 1~2 incorporates balanced standard XLR 3P and DIN 5P sockets on the rear panel.
Inputs 3~4 incorporate balanced standard COMBI socket (1/4” stereo jack, and XLR 3P) and DIN 5P on the 
rear panel. With the input selector 

(35 & 37)

, it is possible to choose the input device (MIC or LINE level ans to

 feed a condenser microphone with 24 V phantom power).
Wiring is as follows

:

XLR 3P

Pin1 : Screen 
Pin2 : Signal (live) 
Pin3 : Signal (return)

DIN 5P

Pin1 : Signal (live) 
Pln2 : GND 
Pin3 : Signal (Return) 
Pin4 : Priority Control 
Pin5 : GND

1/4” STEREO JACK

Tip : Signal (live)
Ring : Signal (Return)
Sleeve : Screen

SLEEVE  RING  TIP

CONNECTIONS

Base sockets

(Front view)

NOTE

: Mic 1 & 2 incorporate phantom power 

look for the 

S 401 and S402

 jumpers on the main PCB. The default position is ON, therefore, change the 

jumper to the OFF position.  

NOTE

: Mic 3 & 4 phantom power can be turned on/off using the rear panel switch 

(35)

,

 (37)

.  

which is ON by default If you need to disable the phantom power, 

Priority Microphones
PA 120 USB/R

 has a cascade priority system, i.e., Mic 1 has the highest priority (apart from TEL/EMER), Mic 2 

has priority over the rest of inputs except Mic 1, Mic 3 has priority over the rest of inputs except Mic 1 & Mic 2, 
and, finally, Mic 4 has priority only over AUX and  USB/SD player/recorder.
To enable priority short pins 2 & 4 on the DIN 5P connector of the chosen input.

- Priority terminals 

(40)

 have the same purpose 

BUT ONLY

   APPLIED TO MIC 1.

Chime On/Off

Switching on the manual chime on/off 

(36)

 switch on the rear panel and on priority conditions of any Mic 

input, it will activate the chime function ( ‘Ding Dong’ ) pre-annoucement chime).
The default volume of the chime is pre-set at the factory and should be suitable most applications.

Turn the front panel potentiometers clockwise to increase the volume or anticlockwise to reduce the volume.

NOTE

: Mic 1 & Mic 2 are provided with a “Sens VR” 

(26)

 &

 (29)

 sensitivity potentiometer for gain adjustment.

- The priority state only remains active whilst the switch is closed.

- If the Chime switch 

(36)

 is set to on, a ‘Ding Dong’ pre-annoucement chime

  will be played; after which an annoncement can be made.

EN

Summary of Contents for PA 120 USB/R

Page 1: ...User Manual Manual de Uso PA 120 USB R Rev 10 15 2 PA 120 USB R...

Page 2: ......

Page 3: ...seek advice from a registered electrician Do not Remove Any Cover Within the product are areas where high voltages may bepresent To reduce the risk of electric shock do not remove any covers unless t...

Page 4: ...8 9 10 12 11 1 13 7 Master Tone Control Bass 1 Mic 1 Volume Control 8 Master Tone Control Treble 2 Mic 2 Volume Control 9 Master Volume Control 3 Input 3 Volume Control 4 Input 4 Volume Control 10 Po...

Page 5: ...o shock all connections have to be accomplished before it is permissible to connect the amplifier to the main supply Before connecting the appliance to the mains supply once again make certain that al...

Page 6: ...memory capacity is 32 GB NOTE This interface provides 3 REPEAT modes showed in the LCD Repeats the playing track Repeats all tracks REP Plays all tracks in random mode NOTE During PLAY mode push these...

Page 7: ...S402 jumpers on the main PCB The default position is ON therefore change the jumper to the OFF position NOTE Mic 3 4 phantom power can be turned on off using the rear panel switch 35 37 which is ON b...

Page 8: ...mixer preamplifier stage to the power amplifier stage The connecting link must be plugged in for normal operation as a mixer amplifier If a compressor limiter equalizer or other external signal proces...

Page 9: ...monitor output allows headphones to be connected Telephone Emergency 39 The Telephone Emergency input is for emergency announcements signals and is not affected by the Master volume control The volume...

Page 10: ...OUTPUTS INPUTS Music Speech 8 100 V ohm 100 V Speechonly Tape 4k7 350 mV ohm Pre out 600 1 V ohm MonitorOutput 8 1W 600 ohm ohm 1V FrequencyResponse 50 Hz 20kHz 3dB EQControl Bass 10dB 31 Hz 180Hz Ce...

Page 11: ...un electricista especializado No retire ninguna cubierta Dentro del producto hay zonas con tensiones altas presentes Para reducir el riesgo de descargas el ctricas no quite las tapas a menos que el ca...

Page 12: ...de Volumen 4 Input 4 Control de Volumen 10 Interruptor Power On Off 5 Line Control de Volumen 12 Indicador LED de encendido apagado 11 Indicador LED de nivel de salida 15 Terminales alimentaci n DC 16...

Page 13: ...as las conexiones tienen que realizarse antes de conectar el amplificador a la alimentaci n principal Aseg rese que todas las conexiones se realizan correctamente y que no existen cortocircuitos La in...

Page 14: ...ntalla LCD Repite la pista que se est ejecutando Repite todas las pistas REP Ejecuta las pistas en orden aleatorio NOTA En el modo PLAY presione estos botones para cambiar a la siguiente o anterior ca...

Page 15: ...ad en cascada es decir Mic 1 tiene la prioridad m s alta aparte de TEL EMER Mic 2 tiene prioridad sobre el resto de las entradas excepto Mic 1 Mic 3 tiene prioridad sobre el resto de las entradas exce...

Page 16: ...un mezclador amplificador Si se utiliza un compresor limitador ecualizador o procesador de se al externo en el sistema de sonido conecte el PRE OUT a la entrada del procesador externo y la salida del...

Page 17: ...es Tel Emer 39 La entrada tel emer es para anuncios de emergencia se ales y no se ve afectado por el control de volumen master El volumen puede ser ajustado por el controlo tel paging 42 Los terminale...

Page 18: ...4k7 350 mV Pre out 600 1 V Monitor Output 8 1W 600 1V Respuesta en Frecuencia 50 Hz 20 kHz 3dB Control EQ Bass 10 dB 31 Hz 180 Hz Centre frequency 80 Hz Control EQ Treble 10 dB 2k5 Hz 20 kHz Centre f...

Page 19: ......

Page 20: ...equences for the environment and human health which could otherwise be caused by inappropriate waste handling of this product The recycling of materials will help to conserve natural resources For mor...

Reviews: