PowerFLO
™
Series Pumps
12 Volt DC Motor-Driven Diaphragm Pumps
Specifications —
Motor:
Type: 12 VDC, permanent magnet, totally enclosed, non-ventilated
Leads: 18 AWG, 12” long
Temperature Limits: Motor is not equipped with thermal
protection. For user safety, optimal performance, and
maximum motor life, the motor surface temperature should
not exceed 150°F (66°C)
Pump:
Type: 3 chamber positive displacement diaphragm pump, self
priming, capable of being run dry, demand or bypass model.
Certifications: NSF Standard 58
Liquid Temperature: 140°F (60°C) Max.
Priming Capabilities: 14 feet (4 m)
Max Pressure: 60 PSI
Inlet/Outlet Ports: 7802: Quick Attach
Materials of Construction:
Housing: Polypropylene Diaphragm: Santoprene
Valves: Viton
Fasteners: Stainless steel
Weight: 6 lbs (2.7 kg)
Installation and Operation Precautions —
1. The pump is equipped with a pressure sensing demand switch that
controls the maximum operating pressure.
2. In addition, never subject the pump to pressures above 125 PSI
(8.5 bars).
3. As long as there is inlet water pressure, the pump will not stop
forward flow of water even if the motor is turned off. Be sure the
system has positive means of shutting off water supply.
4. Do not operate pump in an explosive environment. Arcing from the
motor brushes, switch or excessive heat from an improperly cycled
motor may cause an explosion.
5. Do not locate the pump motor near low temperature plastics or
combustible material. The surface temperature of the motor may
exceed 250°F (120°C).
6. Do not pump gasoline or other flammable liquids. Pump head
materials are designed for use with water only. Do not use with
petroleum products.
7. Do not assume fluid compatibility. If the fluid is improperly
matched to the pumps’ elastomers, a leak may occur.
8. To prevent electrical shock, disconnect power before initiating any
work. In the case of pump failure, the motor housing and/or pump
fluid may carry high voltage to components normally considered
safe. Therefore, always consider electrical shock hazard when
working with and handling electrical equipment. If uncertain,
consult an electrician. Electrical wiring should only be done by a
qualified electrician per local and state electrical codes.
Recommendations —
Electrical:
1.
The PowerFlo™ series pumps are designed for intermittent duty.
Make sure that “OFF” periods are sufficient. Refer to Rapid
ON/OFF Operation. Consult the factory for particular data and
design criteria.
2.
Be sure power supply used is adequate for the application.
3. Pump and motor specifictions are based on an alternator
charged battery (13.7 VDC)
4. Use sufficient battery supply power. UTV and lawn tractor batteries
may affect pump performance due to low voltage and amp ratings.
Servicing —
Every Year: Check system against operating standards.
Every 2-3 Years: We recommend replacing the diaphragm and
checking against operating standards.
* Important return safety instructions:
When you return your pump for warranty or repair, you must always do the following:
1. Flush chemical residue from the pump (best done in the field).
2. Tag pump with type of chemicals having been sprayed.
3. Include complete description of operation problem, such as how pump was used,
symptoms of malfunction, etc. Since pumps can contain residues of toxic chemicals
these steps are necessary to protect all the people who handle return shipments, and
to help pinpoint the reason for the breakdown.
Model: 7802: 2.2 GPM
PRECISION SPRAY EQUIPMENT
®
, a divison of Green Leaf, Inc. 9490 N BALDWIN ST FONTANET, IN 47851 www.green-leaf.us 800-654-9808
a division of Green Leaf, Inc
®
P R E C I S I O N S P R AY E Q U I P M E N T
PSE
®
®
Specifications —
Motor:
Type: 12 VDC, permanent magnet, totally enclosed, non-ventilated
Leads: 14 AWG, 12” long
Temperature Limits: Motor is not equipped with thermal
protection. For user safety, optimal performance, and
maximum motor life, the motor surface temperature should
not exceed 180°F (82°C)
Pump:
Type: 5 chamber positive displacement diaphragm pump, self
priming, capable of being run dry, demand or bypass mode.
Certifications: NSF Standard 58
Liquid Temperature: 140°F (60°C) Max.
Priming Capabilities: 14 feet (4 m)
Max Pressure: 45 PSI
Inlet/Outlet Ports: 5900: Quick Attach
Materials of Construction:
Housing: Polypropylene Diaphragm: Santoprene
Valves: Viton
Fasteners: Stainless steel & Zinc plated
Weight: 6 lbs (2.7 kg)
Model: 5900: 5.0 GPM
12/2017