8
This is how your heat pump works
65
Commissioning report
Three-way valve
The valve switches between
heating and hot water.
Filter
The filter can be opened for easy
cleaning. It also has a shut off
function.
Electric heater
The electric heater is used to
provide extra output in cold
weather conditions, with large
water consumption and at hot
water peaks.
Reset button
Press in the button if the overheat
protector on the electric heater
has tripped. The button is located
on the side.
Condenser
The condenser condenses the
vapour to fluid again and transfers
the heat to the heating system.
Circulation pump
The pump ensures the heating
water circulates within the
heating system.
Flexible hoses
The hoses counter act vibrations
in the heat pump.
Compressor
The compressor increases the
pressure of the refrigerant. The
temperature of the vapour
increases from 0ºC to
approxi100ºC. The
compressor is insulated to reduce
the noise level.
Electrical connections
Connections for the mains supply
as well as sensors.
Control panel
The control panel has a back-
ground lit menu display with four
rows of text information, three
buttons and a dial.
Distribution box
The distribution box is enclosed.
It houses a reset function for the
motor cut-out as well as miniature
circuit breakers (MCB) for the
heat pump and electric heater.
Control unit
The control unit is enclosed. It
controls and monitors all heat
pump functions.
Evaporator
The evaporator evaporates the
refrigerant to gas and transfers
heat from the heat transfer fluid to
the refrigerant circuit.
Heat transfer fluid pump
The pump is insulated and
features an anti-corrosive finish. It
ensures the heat transfer fluid
circulates from, e.g. the energy
source to the heat pump.
Expansion valve
Lowers the pressure of the
refrigerant that enters the
evaporator.
Sight glass
Sight glass to check the level
in the refrigerant circuit. Air
bubbles must not form in the
sight glass when the heat
pump is running. However,
there might be bubbles when
the heat pump is started and
stopped.
Client / Installation address:
Installer:
Type of equipment:
Commissioning date:
Type of ground collector (bore hole, horizontal loop, compact collector):
Total length of collector:
Other components of the installation:
Additional heat
(boiler, solar etc)
Hot water cylinder
Three-way valve
(mixer valve, zone valve)
Serial number:
Room sensor T5 (G5)
Hot water cylinder
temperature sensor T3 (GT3)
Mixing valve sensor T4 (GT4)
Others:
Notes:
filled
Ground collector system
(pressurised and vented):
checked
Notes:
set
Electric heater 3 6 9 kW:
checked
Notes:
checked
Filters:
cleaned
Notes:
checked
Sight glass (green):
Notes:
filled
Heating system (pressured
and vented):
checked
Points to be checked prior to commissioning
Temperature after 10 minutes heating or hot water mode:
Heat flow out T8 (GT8):
/
°C
Heat return in T9 (GT9):
Collector fluid in T10 (GT10):
/
°C
Collector fluid out T11 (GT11):
Heating pump G2 (P2) working correctly
Collector pump G3 (P3) working correctly
/
°C
/
°C
TECHNICAL INFORMA
TION
FOR THE USER
FOR THE INST
ALLER