Information for installer
6 720 648 748 (2014/03)
5.3
Settings in the service menu
Overview of settings
Adjustments
Adjustment
range
1)
1) Values in bold = default setting
Description
A.1
CO | Fb |
SC
Controller (CO), room thermostat (Fb), zone
controller (SC)
H.C
HC1 | HC2 |
HC3 | HC4
Heating circuit 1 to 4
2)
2) Only one Sense I can be assigned per heating circuit.
d.1
2 |
3
| 4
Control characteristics:
•
2: Fast (for high operating temperature and
small volume of heating water)
•
3: Average (for radiator heating system and
medium operating temperature)
•
4: Slow (for underfloor heating system and low
operating temperature)
E.1
– 3.0 ...
0.0
... + 3.0
If the room temperature displayed by the Sense I is
wrong, correct the deviation up to ±3 °C
3)
.
3) Temporarily place an appropriate thermometer next to the Sense I for
comparative measurement. Keep away from heat sources for 1 hour.
P.1
4
| 5
Flow temperature control (4) or load
compensation (5)
L.1
1
| 0
Optimised pump run: pump run time at flow
temperature control is maximally shortened. Must
be switched off with buffer tanks in the system.
C.1
C
| F
Unit of displayed temperatures °C (C) or °F (F)
S.1
nF.12.01
Software version
4)
4) Turn the control knob to read off the whole value.
F.1
1 |
0
1: Factory settings after reset/power failure
0: System settings maintained after reset/power
failure