![Worcester Greenstar Oilfit Flexi CF Flue Installation Instructions Manual Download Page 4](http://html1.mh-extra.com/html/worcester/greenstar-oilfit-flexi-cf-flue/greenstar-oilfit-flexi-cf-flue_installation-instructions-manual_996563004.webp)
Product information
Greenstar Oilfit Flexi CF Flue – 6720807911 2019/05
4
2.1
Vertical CF kit components
Greenstar Utility 25/32 and 32/70
130mmØ CF Vertical flue kit
Part number: 7 716 190 049
Fig. 1
CF Vertical flue kit 130mm
[8]
Adaptor 100mmØ to 130mmØ
[9]
Elbow
[10] Elbow support bracket
2.2
CF Flexible flue liner kit components (100mmØ )
100mmØ Flexible flue liner kits:
8 metre - part number: 7 733 601 205
12 metre - part number: 7 733 601 206
Fig. 2
CF Flexible flue liner components (100mm)
Chimney gasket
▶ The self adhesive chimney gasket does not have to be used, but may
be required if there are large irregularities on the chimney top face.
Fig. 3
CF Flexible flue liner components (100mm)
[1]
Chimney cowl
[2]
Chimney gasket
[3]
Terminal
[4]
Support bracket assembly
[5]
Centralising spacer
[6]
Flue damper assembly
[7]
Flexible to rigid adapter kit
[8]
Seal 100mmØ Part number: 8 718 666 509
[9]
Flexible liner (8 or12 metres)
[10] Rigid to flexible adapter kit
NOTICE:
Seals
▶ Seals [7] must be located at the top and bottom of the flexible flue
liner [8]. Refer to figures 16 and 18.
672080791
1-02.1W
o
8
9
10
1
3
4
0010028880-001
2
5
6
8
9
10
7
8