4

GENERAL INFORMATION

6 720 803 600 (2012/06)

FITTINGS AND MODIFICATIONS:

Only a competent engineer can remove the boiler case and carry out any work, in accordance with the Gas Safety (Installation and 
Use) Regulations.

Do not remove the boiler case. 

Any misuse or unauthorised modifications to the boiler, flue or associated accessories and heating system will invalidate the 
guarantee.

Do not modify the boiler or flue system in any way.

Worcester, Bosch Group accepts no liability arising from any such actions. This does not affect your statutory rights.

2

GENERAL INFORMATION

SERVICING

The boiler must be serviced regularly by a competent, qualified person, such as a Worcester service engineer or other Gas Safe 
registered engineer.

Always use original spares, to help maintain the efficiency, safety and reliability of the boiler and have the Service Record 
completed in the Benchmark Checklist.

The completed Benchmark Checklist will be required in the event of any guarantee work and may be required by the local Building 
Control Inspector.

BENCHMARK STANDARD

The Benchmark initiative is a code of practice to encourage the correct installation, commissioning 
and servicing of domestic central heating boilers and system equipment.
A “checklist” is dispatched with every boiler. This is a vital document that needs to be completed 
by the installer at the time of installation. It confirms that the boiler has been installed and 
commissioned according to the manufacturer's instructions.

The log book provides space for the recording of regular servicing of the boiler/heating system and this can become a valuable 
document when, for example, you wish to sell the property. The log book will show a potential purchaser that the heating system 
has received regular professional maintenance and servicing during its lifetime.
The Benchmark initiative aims to:

Raise standards among professional installers

Build and maintain high safety standards in the industry

Improve customer satisfaction levels

Make a contribution to the nation's commitment to climate change

Ensure that the service engineer completes the Service Record in the Benchmark Checklist after each service. The 
Benchmark Checklist and service interval record can be found at the rear of the Installation, Commissioning and 
Servicing Instructions.

Summary of Contents for GREENSTAR CDi CLASSIC 29CDi GC

Page 1: ...FED DOMESTIC HOT WATER 6 720 803 600 2012 06 The appliances are for use with Natural Gas or L P G Catt II type C13 C33 Natural Gas 29CDi GC number 47 406 34 34CDi GC number 47 406 36 38CDi GC number 4...

Page 2: ...tremely energy efficient offering you economical running costs and value for money It sits in SEDBUK Band A and is therefore amongst the top energy rated boilers available There is also the reassuranc...

Page 3: ...ter BOILER OPERATION This boiler must only be operated by a responsible adult who has been instructed in understands and is aware of the boiler s operating conditions and effects COMBUSTIBLE AND CORRO...

Page 4: ...ARK STANDARD TheBenchmarkinitiativeisacodeofpracticetoencouragethecorrectinstallation commissioning and servicing of domestic central heating boilers and system equipment A checklist is dispatched wit...

Page 5: ...E E RESET BUTTON F ECO BUTTON DOMESTIC HOT WATER PRE HEAT ON OFF G HOLIDAY BUTTON H DOMESTIC HOT WATER TEMPERATURE CONTROL I CENTRAL HEATING TEMPERATURE CONTROL J SERVICE ENGINEER BUTTON ONLY K SERVIC...

Page 6: ...When the burner is lit the green indicator light underneath the on off switch is illuminated The boiler runs for 15 minutes at minimum heating output to fill the condensate trap The display alternate...

Page 7: ...ter will stay activated If the temperature within the boiler drops to 5 C the boiler will fire to avoid the possibility of freezing To activate frost protection B Leave master switch on B Turn the cen...

Page 8: ...button until it is no longer illuminated To activate ECO mode B Press the ECO button until it is illuminated 3 7 HOLIDAY SETTING Activating the holiday setting will turn off the central heating syste...

Page 9: ...e mains power indicator will stop flashing The boiler will function normally dependent on programmer and room thermostat settings If the fault cannot be cleared by pressing the reset button B Refer to...

Page 10: ...key into the bottom of the charging link and push it upwards The arrow on the key shaft must be in line with the open padlock symbol on the charging link 3 Turn the filling key clockwise to the close...

Page 11: ...eps 1 to 3 5 With filling key in locked position turn the water mains inlet knob white anticlockwise to open This fills the heating system with mains water 6 When the pressure gauge reads 1 5 bar turn...

Page 12: ...re B Re pressurise the system refer to pages 10 Low temperature setting on the boiler controls B Increase settings on boiler controls Desired room temperature too high Radiators are too hot B Turn dow...

Page 13: ...Safe registered personnel Error code Description A7 Hot water NTC sensor defective A8 Break in communication to TD200 or and DT10 b1 Code plug not detected C6 Fan speed too low E2 CH flow NTC sensor...

Page 14: ...pe can be thawed by applying a hot water bottle a microwaveable heating pack the sort used for muscular aches and pains or a cloth soaked in hot water to the exterior of the pipe close to the point of...

Page 15: ...ere has been no heating demand for 24 hours the boiler will run the system pump for a few seconds to reduce the possibility of pump seizure during long periods of inactivity This is usually more frequ...

Page 16: ...ist Our Field Service Engineer finds no fault with the boiler The cause of breakdown is misuse or with other parts of your plumbing heating system or with equipment not supplied by Worcester Bosch Gro...

Page 17: ...atic radiator valves If damaged replace the plastic tops used to adjust the thermostatic radiator valve It is also advisable to manually adjust all thermostatic radiator valves every 2 3 weeks to prev...

Page 18: ...stic purposes for which it was designed This guarantee does not affect your statutory rights GUARANTEE REGISTRATION Your Greenstar boiler carries a two year guarantee against faulty material or manufa...

Page 19: ...to a drain This pipe must not be blocked or altered in any way Room thermostat programmer A room thermostat programmer must be fitted to control the central heating This controls the times and temper...

Page 20: ...0 SPARES 01905 752571 LITERATURE 0844 892 9800 TRAINING 01905 752526 SALES 01905 752640 Worcester Bosch Group Cotswold Way Warndon Worcester WR4 9SW Tel 0844 892 9900 Worcester Bosch Group is a brand...

Reviews: