Installation
9
Greenstar 80mm Flexi RF Flue – 6721814542 2019/09
Fig. 12 Fitting the adaptor
[1]
Flexible flue liner
[2]
Seal
[3]
Grease
[4]
Flue adaptor
The centralising spacer must be shortened to fit the 80mm flexible liner.
Snap off the centralising spacer at the perforated section marked 80mm
to suit the flue.
Secure the centralising spacer around the flexible liner as shown in
fig. 14
Fig. 13 Flue spacer
Fig. 14 Fitting spacers
The centralising spacers must be fitted to the flexible liner in certain
positions to ensure the liner is centred within the chimney.For a chimney
with a bend place the centralising spacers at positions shown in
figure 15.
Place a centralising spacer at least every 2500mm on the vertical parts
of the chimney.
Fig. 15 Positioning spacers