Technical Specifications/Logs
67
Greenstar 8000 Life – 6720883865 (2019/02)
Table 31 GR8300iW 40/45
Maximum power consumption (running)
W
130
130
130
130
Maximum power consumption (stand-by)
W
1
1
1
1
Energy efficiency index (EEI) heating pump
–
≤ 0.23
≤ 0.23
≤ 0.23
≤ 0.23
General data
Expansion vessel capacity
l
10.0
10.0
10.0
10.0
Expansion vessel pre-charge pressure
bar
1.0
1.0
1.0
1.0
Appliance protection rating
4)
IP
X4D
X4D
X4D
X4D
Permissible ambient temperature short time/long time
°C
0–50/40
0–50/40
0–50/40
0–50/40
Nominal capacity of the appliance
l
5.2
5.2
5.9
5.9
Total packaged weight
kg
55
55
57
57
Total appliance weight (excluding packaging)
kg
47
47
49
49
Lift weight (without front and side panels)
kg
41
41
43
43
1) Propane/butane mixture for fixed containers with capacity up to 15 000 l
2) The Gas Rate provided assuumes the accepted NG average calorific value of 34-9 MJ/m
3
net .
3) Appliances are fitted with a flow regulator set to achieve a 40 °C temperature rise. This ensures comfortable bathing during the colder winter months.
4) Protection rating may change depending on the control unit/s used on this appliance.
GR8300iW 50
Unit
Natural gas
Propane
1)
Gas flow maximum rate – 10 minutes from lighting
Natural Gas
2)
m
3
/h
5.1
–
Propane Gas (LPG)
kg/h
–
3.8
Central Heating (CH)
Maximum rated heat input (net) (Q
max
) kW
34.4
34.4
Maximum rated heat output 40/30 °C
kW
36.0
36.0
Maximum rated heat output 50/30 °C (P
cond, max
) kW
35.7
35.7
Maximum rated heat output 80/60 °C (P
max
)
kW
33.8
33.8
Minimum rated heat input (net) (Q
min
) kW
5.1
5.1
Minimum rated heat output 40/30 °C
kW
5.5
5.5
Minimum rated heat output 50/30 °C (P
cond, min
)
kW
5.5
5.5
Minimum rated heat output 80/60 °C (P
min
)
kW
5.0
5.0
Maximum flow temperature
°C
70
70
Maximum flow temperature possible
°C
82
82
Maximum permissible operating pressure (PMS)
bar
2.5
2.5
Available pump head at 20 °C system temperature rise
m
2.0
2.0
Domestic Hot Water DHW
Minimum heat input
kW
6.3
6.3
Maximum rated heat input (net) (Q
n
W)
kW
48.9
48.9
Maximum rated heat output (P
n
W)
kW
48.9
48.9
Maximum mains inlet pressure (standing pressure PMW)
bar
10
10
Minimum mains inlet pressure (working) for max. flow
bar
2.5
2.5
Minimum mains inlet pressure (working) for operation
bar
0.2
0.2
Minimum required flow to activate DHW demand
l/min
1.9
1.9
DHW temperature range
°C
35-60
35-60
Maximum cold water inlet temperature
°C
60
60
Maximum DHW flow rate - 40 °C rise ± 15%
3)
l/min
18
18
GR8300iW 40
GR8300iW 45
Unit
Natural gas
Propane
1)
Natural gas
Propane
1)