Worcester GR8700iW 30 S NG User Instructions Download Page 9

Operating the appliance

9

Greenstar 8000 Style – 6720883869 (2021/05)

Table 3 Symbols in the display

The heating and hot water settings have been adjusted by the installer to 
the appliance’s optimum settings.

▶ Before making any adjustments it is advisable to make a note of these 

settings so that you can return to these optimum settings in the 
future.

4.3

Adjusting the appliance flow temperature

4.3.1

Heating key

The heating key is used to set the max. flow temperature. The maximum 
flow temperature can be set between 30 °C and 88 °C

1)

. The current 

flow temperature is shown on the display. 

With underfloor heating systems observe the maximum permissible flow 
temperature.

▶ Press the 

(

 key.

The set maximum flow temperature appears.

▶ Press the

 or 

 keys to set the desired maximum flow temperature.

Table 4 Maximum flow temperature

▶ To save the setting, press the 

ok 

key or wait for 2 seconds.

The symbol 

 appears for a short time. 

If a time program is activated and set on 

auto

 press the 

ok 

key to switch 

to 

Advance

. Time programs are available with Key (accessories).

auto

: Heating is switched on and off according to programmed times for 

heating.

Advance

: Switch to 

Advance

 to move to the next on or off time and 

directly switch on or off heating.

4.4

Hot water mode

4.4.1

Hot water key

Hot water function is only available with optional integral diverter valve 
kit fitted.

CAUTION

Risk of scalding

At maximum adjusted hot water temperature can cause serious scalding.

▶ Only use the maximum adjustable hot water temperature for thermal 

disinfection.

▶ Press the

 *

 key.

The set hot water temperature appears.

▶ To set the desired hot water temperature, press the 

 or 

 keys.

▶ To save the setting, press the 

ok 

key or wait for 2 seconds.

The symbol 

 appears for a short time.

▶ To switch hot water operation mode, press the 

ok 

key.

In 

eco

 mode the appliance will heat the cylinder if the temperature falls 

approximately 12 °C below the set temperature. Eco mode is enabled by 
default, during the initial appliance start up.

In 

Preheat

 mode the appliance will heat the cylinder if the temperature 

falls approximately 6 °C below the set temperature. The appliance heats 
the cylinder more frequently. This tops up the cylinder temperature for 
quicker heat up times, this is useful for large/longer demand periods.

If a time program is available and hot water operation mode set on 

auto

 

press the 

ok 

key to switch to 

Advance

. Time programs are available with 

Key (accessories).

Auto

: Heating the cylinder is switched on and off according to 

programmed times.

Advance

: Switch to 

Advance

 to move to the next on or off time and 

directly switch on or off heating the cylinder.

4.5

Operating the menu

Opening and closing the menu

▶ To open the menu, press the 

 key.

▶ To exit the menu, press the 

 key again.

-or-

▶ Press the 

d

 key.

Changing the setting values

▶ To highlight a menu item, press the 

 key or the 

 key.

▶ Select the menu item with the 

ok 

key.

▶ To change the value, press the 

 or 

 key.

▶ Press the 

ok 

key.

The new value is saved.

Exiting the menu without saving values

▶ Press the 

d

 key.

Gas consumption

Electricity consumption

1) The energy values shown are an estimation based on internal data of the 

appliance. Under real world conditions, many factors influence the energy 
consumption and the shown values will deviate from the values of an energy 
meter. The information is for indication only and should not be used for billing 
purposes. The values can be used for relative comparison of energy consumption 
between different days/weeks/month.

1) The maximum value can be reduced by the service technician.

Supply temperature

Sample application

Approx. 50 °C

Underfloor heating system

Approx. 75 °C

Radiator heating system

Approx. 82 °C

Convector heating system

Symbol

Explanation

kWh

kWh

Summary of Contents for GR8700iW 30 S NG

Page 1: ...6720883869 2021 05 UK IE User Instructions Gas fired condensing system boiler Greenstar 8000 Style GR8700iW 30 S NG GR8700iW 35 S NG GR8700iW 30 SB NG GR8700iW 35 SB NG...

Page 2: ...are of exceptional quality and proven reliability Our products employ the latest technologies and they are reliable extremely energy efficient offering you economical running costs and value for money...

Page 3: ...9 4 5 Operating the menu 9 4 6 Settings in the menu 10 5 Key accessories 10 5 1 Installing the Key 10 5 2 Key LED 11 5 3 Setting the time program 11 6 Shutdown 11 6 1 Setting frost protection 11 7 The...

Page 4: ...A gas leak could potentially cause an explosion If you smell gas observe the following rules Prevent flames or sparks Do not smoke use a lighter or strike matches Do not operate any electrical switche...

Page 5: ...be free of flammable or chemically aggressive substances Do not store or use any flammable or explosive materials paper petrol thinners paints etc in the vicinity of the heat source Do not store or u...

Page 6: ...ther Gas Safe registeredengineer IntheRepublicofIrelandservicingworkmustbe carried out by a Worcester service engineer or other Registered Gas Installer RGII Alwaysuseoriginalspares tohelpmaintainthee...

Page 7: ...bar If a permanent significant decrease or increase in pressure is shown on the pressure indicator contact your installer or maintenance engineer Pressure indicator Type of pressure indicator for the...

Page 8: ...bleeding the pressure drops off Once the pressure has settled between 1 and 1 5 bar Ensure the valves are closed Remove the hose 2 and replace the blanking cap 1 Fig 3 If the indicator is on the righ...

Page 9: ...peration mode press the ok key In eco mode the appliance will heat the cylinder if the temperature falls approximately12 C below the set temperature Eco mode isenabled by default during the initial ap...

Page 10: ...me prog 1 Timer for hot water Weekday s selection day program and timer adjustment Time program page 11 1 Boiler status Screen with current system values including the pressure indicator Information T...

Page 11: ...m adjustable hot water temperature for thermal disinfection Inform occupants of the premises of the risk of scalding Perform thermal disinfection outside of the normal operating times Do not discharge...

Page 12: ...ion Installer maintenance engineer Table 8 Worcester Bosch Group The appliance is supported in the UK and Eire by Worcester Bosch Group Specialist service engineers are available to attend an applianc...

Page 13: ...Itislikelythatthepipeisfrozenatthemostexposedpointoutside thebuildingorwherethereisanobstructiontoflow Thiscouldbe the open end of the pipe at a bend or elbow or where there is a sag in the pipe in w...

Page 14: ...onstantly have to top up your boilers pressure Can you confirm that the filling link is not stuck open passing water in any way Does system pressure increase when the boiler is on Does the system pres...

Page 15: ...usehold waste Used batteries must be disposed of in local collection systems 11 Tips on energy saving Heating economically The appliance provides a high level of comfort whilst keeping fuel consumptio...

Page 16: ...designed This guarantee does not affect your statutory rights Guarantee registration Your appliance product carries a guarantee against faulty material or manufacture subject to Terms and Conditions T...

Page 17: ...tion average climate conditions QHE kWH Annual energy consumption QHE GJ 69 78 Sound power level indoors LWA dB 53 53 Special precautions to be taken during assembly installation or maintenance if app...

Page 18: ...ecomponentto the required extent This shall not apply for other components of the software 14 2 Used Commercial Source Components 14 2 1 This product contains software developed and licensed by SEGGER...

Page 19: ...ials provided with the distribution 3 Neither the name of STMicroelectronics nor the names of other contributors to this software may be used to endorse or promote products derived from this software...

Page 20: ...Kingdom Tel 0330 123 9559 worcester bosch co uk TECHNICAL SUPPORT 0330 123 3366 RENEWABLE SUPPORT 0330 123 9229 CONTROLS AND CONNECTIVITY TEAM 0330 123 3641 APPOINTMENTS 0330 123 9339 SPARES 0330 123...

Reviews: