INSTALLATION
6 720 648 726 (2011/07)
23
8.2.9
INSTALLING THE CONDENSATE TRAP
B
Fill the condensate trap (supplied with the boiler)
with water (
Æ
fig. 16).
Fig. 16 Filling the condensate trap with water
B
Connect the condensate trap [1] to the condensate
drain outlet (CDO).
Fig. 17 Installing the condensate trap
1
Condensate trap
B
Connect the condensate trap hose [3] and the rubber
sleeve [2] to the condensate trap [1].
Fig. 18 Installing the condensate trap hose
1
Condensate trap
2
Rubber sleeve
3
Condensate trap hose
8.2.10 CONDENSATE REMOVAL
POSITIONING AND TERMINATION OF THE
CONDENSATE DRAIN PIPE
The condensate pipe should run and connected to the
internal sewage pipe in the house or waste pipe.
Alternatively, the condensate can be discharged into the
rainwater system if connected to a foul water draining
system, or into a purpose-made soak away (condensate
absorption point).
All connecting drainage pipework should generally have
a fall of at least 2.5° to the horizontal, or approximately
50 mm per metre of pipe run. If this is can-not be
achieved, consider the use of a sewage pump.
It should be noted that the connection of a condensate
pipe to a drain may be subject to local building controls.
MATERIAL FOR CONDENSATE
The condensate drainage pipe should be run in a
standard drain pipe material, e.g. PVC (polyvinyl
chloride), PVC-U (unplasticized polyvinyl chloride), BS
(acrylonitrile-butadienestyrene), PP (polypropylene
polyprolene) or PVC-C (cross-linked polyvinyl chloride).
Any internal pipework should be of a diameter to match
the requirements of the condensate exit pipe on the
appliance.
DANGER:
Danger of fatal accident due to
poisoning.
B
If the condensate trap is not filled with
water, flue gas can escape and put
people's lives at risk.
The trap is fitted with a bayonet connection.
After pushing [step 1] the trap upwards into
place, you have to turn it a ¼ turn
anticlockwise [step 2] until it locks into
position.
6 720 648 726-016.1TD
1.
2.
1
6 720 648 726-017.1TD
1
WARNING:
Any external run must be insulated with
water proof insulation.
Ensure that the condensate trap is filled
with water.
6 720 648 726-018.1TD
3
2
1