background image

SET?

SELECT

YES

Digistat Optimiser

SET?

SELECT

YES

Digistat

DIGISTAT - 

Radio frequency controlled programmable room thermostat

with domestic hot water programmer

FOR GREENSTAR i and GREENSTAR Si MODELS

OPTIMISING DIGISTAT - 

Radio frequency controlled programmable

optimising room thermostat with domestic hot water programmer

FOR GREENSTAR Si MODELS

INSTRUCTION MANUAL

FITTING & OPERATING INSTRUCTIONS

DT10RF PROGRAMMER

DT10RF OPTIMISING PROGRAMMER

set?

OK

off

timed

once

on

select

advance

MON  TUE  WED  THU  FRI  SAT  SUN

CLOCK?  PROG?  DATE?  HDAY?

AM     OFF

C

HW  ON

SET?

SELECT

YES

Digistat Optimiser

SET?

SELECT

YES

Digistat

FOR GREENSTAR Si MODELS

off

timed

once

on

MON  TUE  WED  THU  FRI  SAT  SUN

CLOCK?  PROG?  DATE?  HDAY?

AM     OFF

C

HW  ON

SET?

SELECT

YES

SET?

SELECT

YES

Digistat

set?

OK

off

timed

once

on

select

advance

MON  TUE  WED  THU  FRI  SAT  SUN

CLOCK?  PROG?  DATE?  HDAY?

AM     OFF

C

HW  ON

All manuals and user guides at all-guides.com

all-guides.com

Summary of Contents for DT10RF

Page 1: ...NUAL FITTING OPERATING INSTRUCTIONS DT10RF PROGRAMMER DT10RF OPTIMISING PROGRAMMER set OK off timed once on select advance MON TUE WED THU FRI SAT SUN CLOCK PROG DATE HDAY AM OFF CHW ON SET SELECT YES Digistat Optimiser SET SELECT YES Digistat FOR GREENSTAR Si MODELS off timed once on MON TUE WED THU FRI SAT SUN CLOCK PROG DATE HDAY AM OFF CHW ON SET SELECT YES SET SELECT YES Digistat set OK off t...

Page 2: ... LEAD TO PROSECUTION LEAVE THESE INSTRUCTIONS WITH THE USER OR AT THE APPLIANCE CONTACT INFORMATION WORCESTER BOSCH TECHNICAL 08705 266241 SERVICE 08547 256206 SPARES 01905 752571 LITERATURE 01905 752556 TRAINING 01905 752526 SALES 01905 752640 WEBSITE www worcester bosch co uk MANUAL INFORMATION ABBREVIATIONS CH Central Heating HW Domestic Hot Water RF Radio Frequency DLS Day Light Saving BST Bri...

Page 3: ...R LOCATION CLEARANCE FIXING 6 USER INSTRUCTIONS TRANSMITTER OPERATING CONTROLS 7 TRANSMITTER PRE SET PROGRAMS 8 TRANSMITTER SETTINGS Setting the clock 9 Setting times and temperatures 10 11 RECEIVER OPERATING CONTROLS 12 RECEIVER PRE SET PROGRAMS 13 RECEIVER SETTING PROGRAMS Setting MON FRI 14 Setting individual weekdays 15 Setting SAT SUN 16 Setting individual weekend days 17 RECEIVER SETTING HOL...

Page 4: ...re wired with PCB connector Digistat transmitter Radio frequency controlled programmable room thermostat with domestic hot water programmer Remote 24 hour programmable RF Transmitter to control CH temperature AA alkaline LR6 batteries included Low battery warning Max signal range approx 25 metres range may decrease according to the building construction Digistat Optimising transmitter Radio freque...

Page 5: ...ction II Degree of protection IP 24 Accuracy 25 C sec day 1 Battery life years 10 Battery backup time date years min 10 Shortest switching period minutes 1 On Off periods number 3 Programs days 7 Related Standards BS EN60730 1 2001 BS EN60730 2 7 1992 Electro Magnetic Compatibility and Radio Spectrum Matters ERM Short Range Devices SRD ETSI EN 300 220 1 EC Directives European Union Law Directive 2...

Page 6: ...ove 3 Grip tab C pull upwards to disengage clips D and pull forwards to remove blanking plate E or existing programmer 4 Align connector pins F into receptors G in the pcb and push fully home 5 Feed the ribbon cable G into recess H 6 Align programmer E and locate clips D push into slots then downwards to secure using grip tab C 7 Locate cover panel B and secure with screw A Replace fascia cover an...

Page 7: ...5 Slide open battery compartments B 6 Remove insulator strips C 7 Replace the right hand battery compartment B first followed by the left hand battery compartment The display D then shows the room temperature and automatically transmits a signal to the receiver unit in the boiler to establish a radio link 8 When a radio link has been established the display reverts back to normal operation with th...

Page 8: ...ansmitter away from light and heat sources enclosures and curtains direct draughts including fans air vents windows and doors damp and condensation Replacing a mains wired unit Isolate the main electric supply Refer to the manufacturers instructions to remove the unit Isolate the existing wiring and make electrically safe Transmitter clearances See diagram opposite for minimum area required for op...

Page 9: ...ature Note the following only occurs during a timed on period and has no effect when the receiver is in an off setting 2 To increase the room temperature press the button until the required temperature is displayed 3 To decrease the room temperature press the button until the flame symbol is no longer displayed After 5 seconds the display reverts back to the actual room temperature Optimium start ...

Page 10: ...s Press the select and buttons together and hold for 2 seconds to reset the default program times See TRANSMITTER SETTING PROGRAMS in the USER INSTRUCTIONS section if changes are required to the clock time or pre programmed settings 1 2 3 Central Heating MON to FRI Start time 6 30 8 30 16 30 22 30 Temperature C 20 16 21 7 SAT SUN Start time 7 00 9 00 16 00 23 00 Temperature C 20 16 21 7 1 2 3 Cent...

Page 11: ...Press YES and the hours flash 3 Press to set correct hour 4 Press SET and the minutes flash 5 Press to change minutes Press SET twice to return to normal running mode Digistat Optimiser only 6 Press SET a day of the week flashes 1 Monday 7 Sunday 7 Press to choose day 8 Press SET twice to return to normal operation SET SELECT YES SET SELECT YES SET SELECT YES SET SELECT YES SET SELECT YES 1 2 3 4 ...

Page 12: ...e temperature flashes for the 1st ON period 3 Press to change the temperature for the 1st ON period 4 Press SET the start time flashes 5 Press to change the start time 6 Press SET the temperature flashes for the next start period 7 Press to change the temperature for the next ON period Repeat steps 4 to 7 for the 3rd period then the night ON periods Press SET to return to normal display SET SELECT...

Page 13: ...e start time flashes 6 Press to change the start time 7 Press SET the temperature flashes for the next start period 8 Press to change the temperature for the next ON period Repeat steps 5 to 8 for the 3rd period then the night ON periods Complete the 1 5 Mon Fri settings until the option to change each day is displayed 9 To change the individual day settings press YES and repeat steps 5 to 8 or pr...

Page 14: ...me periods as program once ON from 1st ON until 3rd OFF time period as program on constantly ON 2 Press advance button ON hot water light on hot water stays on until the next OFF time period OFF hot water light off hot water stays off until the next ON time period Note advance has no effect with the constant on or off selected on the receiver or when there is no demand from the transmitter RECEIVE...

Page 15: ...ite The default ON OFF periods pre programmed for DHW are shown in the table opposite Note two ON OFF periods can be used instead of 3 by setting the 2nd ON OFF periods to 12 00 as shown in the default program table One ON OFF period can be achieved by setting the 2nd and 3rd ON OFF periods to the same time See RECEIVER SETTING PROGRAMS in the USER INSTRUCTIONS section if changes are required to t...

Page 16: ... OK to select ON time Note speed up the display by holding down the or buttons 4 Press or to change the ON time 5 Press set to set the ON time and select the OFF time 6 Press or to change the OFF time 7 Press set to set the OFF time and select the next ON time Repeat operations 4 to 7 to set the 2nd and 3rd ON OFF times Note after pressing set for the 3rd HW OFF time the display shows SET MON see ...

Page 17: ...irst day you want to change is displayed 1 Press OK to select weekday 2 Press OK to select 1st ON time Note speed up the display by holding down the or buttons 3 Press or to change the ON time 4 Press set to set the ON time and select the OFF time 5 Press or to change the OFF time 6 Press set to set the OFF time and select the next ON time Repeat operations 3 to 6 to set the 2nd and 3rd ON OFF tim...

Page 18: ...r buttons 2 Press or to change the ON time 3 Press set to set the ON time and select the OFF time 4 Press or to change the OFF time 5 Press set to set the OFF time and select the next ON time Repeat operations 2 to 5 to set the 2nd and 3rd ON OFF times Note after pressing set for the 3rd OFF time the display shows SET SAT see next page If you do not require individual weekend times then press SET ...

Page 19: ...do not wish to change the settings for SAT then press set to move to SUN 1 Press OK to select the day displayed Note speed up the display by holding down the or buttons 2 Press or to change the ON time 3 Press set to set the ON time and select the OFF time 4 Press or to change the OFF time 5 Press set to set the OFF time and select the next ON time Repeat operations 2 to 5 to set the 2nd and 3rd O...

Page 20: ...r of days you require the system to be off 4 Press set then HDAY is shown in the display and no demand for heating will be made from the programmer The program will return to normal after the set number of days To cancel the holiday setting and return to normal operation press any button Note the programmer counts each pass through midnight as a day For example if you don t want the heating on fro...

Page 21: ...e display 5 Press or to correct hour Note speed up the display by holding down the or buttons 6 Press the set button to set the correct hour and the minutes flash 7 Press or to correct minutes 8 Press the set button to set the correct minutes SET DATE appears in the display Note if the day displayed is incorrect the date needs resetting To change the date see SETTING THE DATE If you do not wish to...

Page 22: ...on until SET DATE are shown in the display 2 Press the OK button once the year flashes on the display 3 Press or to correct year 4 Press the set button and the month flashes on the display 5 Press or to correct month 6 Press the set button and the day flashes on the display 7 Press or to correct day 8 Press the set button to set the DLS and ON flashes 9 Press or for ON or OFF 10Press set twice to ...

Page 23: ...e the batteries are removed you have 1 minute to replace the batteries before your program settings are lost Replacing the batteries Do not use rechargeable batteries 1 Slide open battery compartments B 2 Remove existing batteries C and dispose of safely Replace batteries with the same type and check they are correctly fitted into the battery compartments C 3 Replace the right hand battery compart...

Page 24: ...ese units cannot be serviced Should the existing unit fail to function correctly check receiver times and program settings are correct the RF signal link is setup transmitter batteries are the correct type and are correctly fitted Replacement Parts Digistat Optimiser 7 day transmitter part number 8 716 106 668 0 Receiver DT10RF part number 8 716 106 667 0 Digistat Transmitter CH part number 8 716 ...

Reviews: