Product Information
9
Greenstar 4000 – 6 720 891 162 (2020/09)
3.4
Product identification
Data plate
The data plate includes the product performance information, approval
data and serial number. The data plate location can be found in the
product overview.
Additional type plate
The product name and the most important product data are shown on
the additional data plate. The additional type plate can be found on the
outside of the product in an easily accessible location.
The additional type plate can be found on the underside of the appliance.
3.5
Pipework positions and flue outlet
Fig. 2
Pipe and flue outlet dimensions
Table 3 Appliance and flue outlet dimensions
Table 4 Pipe dimensions
Description
Dimensions (mm)
X
Appliance width
400
Y
Appliance height
724
1)
1) 724mm to middle of top panel.
710mm side panel height.
Bottom panel is removable and not part of minimum clearance height
requirements.
Z
Appliance depth
310
W Flue centre from appliance left side
200
D
Flue centre from rear of appliance
135
0010023464-001
1
2
3
4
5
6
7
#
Function
From left
case edge
Diameter of pipe
1
Condensate Outlet 38mm
22mm
• Rubber push fit connection
2
Flow
• CH/Cylinder
1)
1) Cylinder connections shared when optional integral diverter valve kit is not
fitted.
70mm
22mm
• Compression fitting
3
Cylinder Flow
2)
2) Only available if optional integral diverter valve kit is fitted.
135mm
15mm
• Compression fitting
4
Gas
200mm
22mm
• Compression fitting
5
Cylinder Return
2)
265mm
15mm
• Compression fitting
6
PRV Discharge
296mm
15mm
• Fittings not supplied
7
Return
• CH/Cylinder
1)
330mm
22mm
• Compression fitting