ROOM SEALED FLUE OPTIONS
The diagrams (opposite) show the
components used and the maximum flue
length (L) for each flue configuration.
• To achieve the maximum flue legth (L), a flue
section will have to be reduced in legth.
• Only the flue terminal or straight flue
extensions can be reduced in length by
cutting.
• The flue terminal end can be fitted from the
inside or outside of the building.
Calculating the flue length:
Measure the total flue length required, noting
that the maximum straight flue length including
the terminal is:
Then reduce the total straight flue length for
each extra flue bend by:
1000mm for each 90°
500mm for each 45°
Flue Extension Lengths:
Horizontal & Vertical 1000mm overall length.
Effective length when engaged into sockets
within the flue run is 950mm
Flue Terminal Lengths:
Horizontal 80/125mmO: 720mm
Vertical 80/125mmO: cage
Vertical 100/150mmO: cage
*
to outside wall.
IMPORTANT:
All horizontal sections must rise away from
the boiler by 52mm per metre (3°) to allow
the condensate to drain back to the boiler.
Greenstar Danesmoor Kitchen
12/18, 18/25 & 25/32
4000*
6000**
80/125
Greenstar Danesmoor Utility
12/18, 18/25 & 25/32
4000*
6000**
80/125
Greenstar Heatslave
12/18, 18/25 & 25/32
4000*
6000**
80/125
12/18 & 18/25
4000*
8000**
80/125
Greenstar Camray Kitchen
25/32
4000*
-
80/125
-
8000**
100/150
12/18 & 18/25
4000*
8000**
80/125
Greenstar Camray Utility
25/32
4000*
-
80/125
-
8000**
100/150
12/18 & 18/25
4000*
8000**
80/125
Greenstar Camray System
25/32
4000*
-
80/125
-
8000**
100/150
Appliance
Model
Maximum flue length (L)
(mm)
Horizontal
terminal
Vertical
terminal
Flue
diameter
(mm)
*from the boiler casing, (exclude the 120mm of terminal extending beyond the building).
**from the boiler casing (the vertical kit elbow is ignored when calculating the flue length)
HORIZONTAL TERMINAL OPTIONS:
ROOM SEALED FLUE OPTIONS
GREENSTAR OILFIT INSTALLATION INSTRUCTIONS
8 716 106 261b (01/07)
9
P
R
E -
IN
ST
AL
LA
TI
O
N
A
E
B
C
D
A - Horizontal terminal
B - Straight flue extension
C - Flue bend 90
°
D - Flue bend 45
°
E - Vertical Terminal Kit (incl. 90
°
elbow)
L=140-390mm
A
*
L
L=2000mm
125mmO x2
x2
C
+
+
C
+
A
B
*
L
L=4000mm
125mmO x4
+
A
B
L=3000mm
125mmO x3
+
A
B
D
D
+
L=3000mm
125mmO x3
+
A
B
*
*
L
L
C
+
L=3000mm
125mmO x3
+
A
B
*
*
L
L