Porti-P440 Rev. 3.0
http://www.woosim.com
2012-02-06
15
POWER Lamp
(
Green
)
ERROR Lamp
(
Red
)
Option
Communication
Port
1
1
UART
2
Protocol UART
Baud Rate
2
1
9600 bps
2
19200 bps
3
38400 bps
4
57600 bps
5
115200 bps
Data Bit
3
1
7 Data bit
2
8 Data bit
Parity Bit
4
1
No Parity
2
Odd Parity
3
Even Parity
Stop Bit
5
1
1 Stop Bit
2
2 Stop Bit
Density
6
1
Density Low
2
Density Medium
3
Density High
Mark
7
1
No use
2
Use
Sensor
8
1
Low
2
Medium1
3
Medium2
4
High
< Table 2 >