LED Sports Flood Lighting

Model : WSG-P960 (Remote Driver type)

Cable Connection Guide

Installation Instruction

[ How to Connect the Power cable and AC/DC cable ]

 After connecting with a sleeve, wrap it with a

     self-sealing tape.

 In order to prevent flooding with the gap between

     outer part of the cap tire cable and the connecting

     part, wrap up the connecting part of the power

     supply line and the AC/DC line with a self-sealing tape.

 After wrapping it up with the self-sealing tape, use

     electrical tape on top of it.

Do not leave the power box and LED fixture unconnected
(Multiple installation schedule and wiring is prohibited).
In case of inevitable connection of the secondary side
during construction, insulate the ends of the wires with
insulation tape and self-sealing tape to waterproof it.
If following steps are not followed, it may cause product
damage, poor insulation, immersion, non-lighting, short life,
or fire.

Precautions during construction

Self-sealing Tape

① 

② 

③ 

Self-sealing Tape

Electrical Tape

 

Caution / Warning

 

 

The power line is reliably connected with a sleeve or the like. In addition, the insulation tape and self-sealing tape are

     used to reliably insulated and completely waterproof. If the power cable is incompletely connected, there is a risk of

    

 

product damage, electric shock or fire.

 

 

When connecting wires, do not insulate them once, but separate them one by one. Insulate and waterproof them with

    

 

insulating tape and self-sealing tape. Insufficient construction may cause product damage, poor insulation, flooding,

    

 

electric shock or fire.

 

 

When wiring, use insulation tape and self-sealing tape from the connection part of the wire to the outer sheath of the

    

 

wire. Apply over three times (6 plies) of insulation and complete waterproo ng. Insu cient construction may cause

    

 

product damage, poor insulation, flooding, electric shock or fire.

 

 

Insulate each end with self-sealing tape and then tap from the AC / DC side (sheath) to the outer side of the power line.

    

 

Then, wrap it with insulating tape and implement insulation and waterproofing measures.

 

 

Make sure to insulate and waterproof the cable sheath (self-sealing tape, etc.), including the cable sheath as well as the

    

 

conductor. If the insulation/waterproofing is not done properly, immersion may occur from the electric wires, resulting in

    

 

product damage, poor insulation, electric shock, fire, or non-lighting.

Summary of Contents for WSG-P Series

Page 1: ...e is no leakage current when binding the LED xture There is a possibility of LED chip damage due to no load voltage 07 If power is supplied without reliable insulation there is a risk of product damage electric shock or fire 08 Insu cient construction may cause accidents such as product damage poor insulation flooding smoke ignition electric shock or falling 09 Safety wire must be installed to avo...

Page 2: ...illuminance If any cracks are found on the front cover turn o the power immediately and replace it quickly Contact nearest GigaTera Sales O ce for further assistance 27 Do not cover partially or all parts of the product with any sort of object Particularly covering the product may cause deterioration of illuminance non lighting short life and fire 28 If the product especially a heat sink pin is us...

Page 3: ...017 Wooshin Press Lighting Inc All rights reserved www wsled co kr WSG P Series Size 500 x 505 x 344 mm 19 7 x 19 9 x 13 5 inch Weight 17 4 kg 38 4 lb Product Dimension DC Power Cable Black Red WSG P Series Installation Guide LED Sports Flood Lighting Model WSG P960 Remote Driver type ...

Page 4: ... supplied STEP 02 Fix the bracket bolt Bolts are supplied The center of the BKT is fixed with M16 bolts M16Bolt 2EA Turn clockwise STEP 03 Connect the DC Cable to the main power Refer to the DC Power Cable When wiring make sure that the DC cable is su cient RED1 WSG P Series Installation Guide LED Sports Flood Lighting Model WSG P960 Remote Driver type WSG P Series Installation Instruction ...

Page 5: ...tion Warning The power line is reliably connected with a sleeve or the like In addition the insulation tape and self sealing tape are used to reliably insulated and completely waterproof If the power cable is incompletely connected there is a risk of product damage electric shock or fire When connecting wires do not insulate them once but separate them one by one Insulate and waterproof them with ...

Reviews: