background image

Woolly Mammoth Stoves 2016/GB Issue 5 20/10/17 

 

17 

 

 

 

Grate Assembly 

 

Log Retainer 

 

Operational Handles 

 

Baffle Plate 

 

Ash Tray 

 

Insulating Fire Bricks 

Or any damage resulting from: 

 

Misuse 

 

Transit of the stove 

 

Issues with the chimney / flue 

 

Over firing 

 

Wrong fuel 

 

Modifications 

Woolly Mammoth stoves are covered for a period of 5yrs from date of purchase. We will provide 
like for like components (only) free of charge 

excluding any installation or consequential loss 

or costs

. The 

Mammoth Warranty PLUS

 is only valid if installed in accordance with all information 

contained within the User Manual, complies with all current building regulations and signed off by 
a member of the Competent Persons Scheme or Local Building Control Body. Products must be 
installed for their intended purpose only. A warranty form must be completed and returned to the 
supplier of the stove to register the warranty. 

Performance certificates, flue draught readings and registration details of qualified installer used 
will be requested upon any claim under this warranty and failure to complete all information 
requested within the warranty form will render any warranty claim void. All installer details and 
HETAS registration number will be investigated and verified upon receipt of the completed form 
before a warranty is actioned. 

 

 

 

 

 

 

 

Summary of Contents for WM 5

Page 1: ...Woolly Mammoth Stoves 20 28 Albert Road Braintree Essex CM7 3JQ USER MANUAL PLEASE RETAIN THIS GUIDE FOR FUTURE REFERENCE...

Page 2: ...ation Lighting Instructions Page 8 9 Spring Autumn Syndrome Page 10 Over Under Firing Slow Combustion Ash Removal Page 11 Fuel Guide Page 12 13 Maintenance Page 14 Trouble Shooting Page 15 Fire Risk A...

Page 3: ...or solid fuels only Due care must be taken when the stove is in operation as all external surfaces will become hot All local national and European standards must be complied with when installing any s...

Page 4: ...cottish Ministers under section 50 of the Regulatory Reform Scotland Act 2014 In Northern Ireland appliances are exempted by publication on a list by the Department of Agriculture Environment and Rura...

Page 5: ...s for your stove s output Woolly Mammoth stoves must be installed on constructional hearths of non combustible material of at least 125mm depth extending at least 150mm out from the stove either side...

Page 6: ...become misplaced during transit The outlet collar and blanking plate are supplied with screws for securely fixing to the top and rear outlets Woolly Mammoth 5 5WS and 7 only Please check all componen...

Page 7: ...Lighting Your Woolly Mammoth Stove Your new Woolly Mammoth stove is fitted as standard with an adjustable primary air intake controlled by the slider at the base of the model an adjustable secondary a...

Page 8: ...r of small fires to bed in your new stove and ensure the longevity of the metal construction and any coatings You must avoid over firing Note that the Woolly Mammoth 5WS WideScreen WM5 WM7 have modifi...

Page 9: ...n the outside temperature do not light the stove without clarifying that the air is travelling up rather than down the flue As mentioned previously a smell of soot is an indication that the flue is op...

Page 10: ...e primary air control and reduce the secondary air control to no more than 25 This will allow the fuel to burn slowly whilst still emitting a comfortable heat Refuelling onto a low fire bed If there i...

Page 11: ...and steadier than softer woods which will burn quickly and produce less heat We advise the use of Seasoned Hard Wood in log sizes which do not exceed the maximum log size We suggest that you refuel e...

Page 12: ...ith the air controls or appliance dampers open can cause excessive smoke The appliance must not be operated with air controls appliance dampers or door left open except as directed in this user manual...

Page 13: ...als Please use a suitable heat resistant adhesive Check all moveable parts regularly Replacement Parts and Accessories In addition to our market leading 5yr Mammoth warranty PLUS for complete peace of...

Page 14: ...ls intact Are the glass retaining clips loose Is the correct fuel being used It is not unusual to require a draught stabilizer to reduce the draw on a stove due to excessive flue draught Blow Back If...

Page 15: ...l During prolonged use of the stove the radial area will always be of an elevated temperature to the rest of the room Whilst the minimum distances are more than sufficient to fixed items care should b...

Page 16: ...5yr Mammoth Warranty PLUS Your brand new Woolly Mammoth stove has been lovingly crafted and built to last and will be your companion for life if cared for and maintained correctly However in the extre...

Page 17: ...on contained within the User Manual complies with all current building regulations and signed off by a member of the Competent Persons Scheme or Local Building Control Body Products must be installed...

Page 18: ...US Please complete and return to supplier purchased from You will not be able to claim under the terms of the warranty without registering Name Address Telephone Number Email Address Woolly Mammoth 5...

Page 19: ...Woolly Mammoth Stoves 2016 GB Issue 5 20 10 17 19 Installer Information Please complete for your records...

Page 20: ...5 WM 5 Wood Ancit Nominal Heat Output kw 4 9 NA Total Efficiency 79 4 NA Mean CO Emission at 13 O2 0 19 NA Flue Gas Mass Flow g s 4 67 NA Mean Flue Gas Temperature C 244 c NA Height 450mm I Width 370...

Page 21: ...Ancit Nominal Heat Output kw 4 4 4 7 Total Efficiency 73 77 Mean CO Emission at 13 O2 0 17 0 27 Flue Gas Mass Flow g s 5 97 6 62 Mean Flue Gas Temperature C 258 40 c 202 05 Height 480mm I Width 470mm...

Page 22: ...nal Heat Output kw 6 9 N A Total Efficiency 76 1 N A Mean CO Emission at 13 O2 0 2393 N A Flue Gas Mass Flow g s 6 97 N A Mean Flue Gas Temperature C 274 2 c N A Height 550mm I Width 590mm I Depth 410...

Page 23: ...Nominal Heat Output kw 6 N A Total Efficiency 78 N A Mean CO Emission at 13 O2 0 07 N A Flue Gas Mass Flow g s 6 12 N A Mean Flue Gas Temperature C 352 c N A Height 1048mm I Width 518mm I Depth 500mm...

Page 24: ...t Nominal Heat Output kw 7 N A Total Efficiency 79 N A Mean CO Emission at 13 O2 0 09 N A Flue Gas Mass Flow g s 6 43 N A Mean Flue Gas Temperature C 366 c N A Height 1360mm I Width 555mm I Depth 555m...

Page 25: ...Stove Secondary Air Control Unit Placement The SECONDARY AIR CONTROL SLIDER A is located within the SECONDARY AIR CONTROL TUNNEL B It is welded into place during the stove construction process The Tu...

Page 26: ...t Placement Front From Above A 2nd Air Control B Air flow Tunnels The SECONDARY AIR CONTROL SLIDER A is located within the SECONDARY AIR CONTROL TUNNEL B It is welded into place during the stove const...

Page 27: ...Woolly Mammoth Stoves 2016 GB Issue 5 20 10 17 27...

Page 28: ...Woolly Mammoth Stoves 2016 GB Issue 5 20 10 17 28...

Page 29: ...Woolly Mammoth Stoves 2016 GB Issue 5 20 10 17 29...

Reviews: