Summary of Contents for P18

Page 1: ...use care and maintenance of your quality Woodson Starline product Models W CVP C 18 W CVP C 18L W CVP C 24 W CVP C 24L Counter Top Pizza Conveyor Oven P18 P24 SPECIFICATION INSTALLATION AND OPERATION MANUAL READ ALL INSTRUCTIONS BEFORE USE ...

Page 2: ...Page Intentionally Left Blank Page 1 Due to continuous product research and development the information contained herein is subject to change without notice www stoddart com au www stoddart co nz ...

Page 3: ... Setting Up 6 Handling Unpacking Positioning Disposal Electrical Connection 7 Information Wiring Diagram 8 W CVP C 18 W CVP C 24 Technical Specifications 9 W CVP C 18 W CVP C 24 Operation Operating Instructions 10 Control Panel information Operation Adjustments Cross Flow Air Ventilation Switching Unit Off Cleaning and Maintenance Cleaning 12 General Information Corrosion Protection Surface Finish...

Page 4: ...rred to persons units or others due to abuse and misuse of this unit in regards to installation removal operation servicing or maintenance or lack of conformity with the instructions indicated in this documentation Disclaimer All units made by the manufacturer are delivered assembled where possible and ready to install Any installation removal servicing maintenance and access or removal of any par...

Page 5: ...p objects to remove ice from the unit If any fault is detected refer to troubleshooting The manufacturer declines any liability for damages to persons and or things due to an improper wrong and or unreasonable use of the machine Only specifically trained qualified Technicians Stoddart one of our service agents or a similarly qualified persons should carry out any and all repairs maintenance and se...

Page 6: ...h and development the information contained herein is subject to change without notice www stoddart com au www stoddart co nz Installation Conveyor Height Adjustment Exit Rack Control Panel Rating Plate CAUTION Surface is Hot Product Overview ...

Page 7: ...g a clean cloth dampened with warm soapy water Choose an area that is well ventilated and provides access for future maintenance Place the unit on a level stable work surface capable of supporting its weight Do not position the unit in Wet areas Near heat and or steam sources Near flammable substances Allow an air gap between the unit and other objects or surfaces A minimum gap of 100mm from all s...

Page 8: ...o connect the power the unit has a terminal block supplied inside the service compartment This unit must be installed in accordance with AS NZS 60335 1 Some procedures in this manual require the power to the equipment to be turned off and isolated Turn the power OFF at the power point and unplug the power supply lead by the plug body If the power point is not readily accessible turn the equipment o...

Page 9: ...009 690 251 cannot be reproduced without prior permission DESCRIPTION A3 www stoddart com au REV VER REVISED BY DATE REVISION DESCRIPTION STATUS C1 JORDAN HOLDER 28 02 18 START REVISION C FOR MANUFACTURE C2 JORDAN HOLDER 11 12 18 3 PHASE WIRING FIX FOR MANUFACTURE DRAWN APPV D 11 12 2018 Jordan Holder W CVP DC Woodson Starline Conveyor Pizza w Digital Controls Electrica W CVP DC E01 C2 Common Spar...

Page 10: ... 765 635 440 77 55 719 695 610 308 308 1500 750 425 325 778 Specification Technical Specifications 610 480 440 308 308 564 540 457 1500 750 425 325 778 77 55 W CVP C 18 W CVP C 24 Specifications Model W CVP C 18 Height 440mm Width 1500mm Depth 610mm Power 10 8kW 15A 3Ø N E Specifications Model W CVP C 24 Height 440mm Width 1500mm Depth 765mm Power 14 4kW 20A 3Ø N E ...

Page 11: ...he effective power sent to each element For example If the top element is set at 99 and the bottom element is set at 50 there will be approximately double the energy coming from the top element as there is coming from the bottom element To change the element settings press the top or bottom buttons Each press will move the number by 1 The temp is controlled via the temp buttons The display will sh...

Page 12: ...to be no cross flow air ventilation no external fans pointed at the unit This affects the air curtain at entrance and exit of the oven chamber causing temperature instability in the unit Adjust the height of the oven chamber entrance and exit guard to a minimum height above the food product to minimise external airflow entering the unit Do not unplug the unit for at least 30 minutes after the unit...

Page 13: ...perly maintained stainless steel can rust and or corrode Any sign of mild rust and or corrosion should be thoroughly cleaned with warm soapy water and dried as soon as possible NEVER use abrasive pads or cleaners for cleaning All metal surfaces should be checked while cleaning for damage scuffs or scrapes as these can lead to rust and further damage to the product Mild rust and or corrosion can be...

Page 14: ...rticularly seaside environments stainless steel can be subject to surface discolouration or tea staining This can be removed with an appropriate cleaning agent which contains 10 sodium citrate Ask your supplier of cleaning chemicals for a suitable brand Cleaning Procedure External Surfaces 1 Isolate from the power supply 2 Wearing Personal Protective Equipment PPE apply Stainless Cleaner with the ...

Page 15: ...ove foreign object from belt Unit is overheating Airflow blockage O Clear dirt dust from fan guard and or clear all air vents around the unit of any obstructions Fan not working T Replace fan Unit is not heating Elements not working T Replace Elements as required Temp switch Computer board not working T Replace switch Computer board whichever is applicable Solid State Relay contactor failed T Repl...

Page 16: ...w Zealand Business Number 6837694 New Zealand Sales Tel 0800 79 1954 Email sales stoddart co nz Service Spare Parts Tel 0800 935 714 Email service stoddart co nz Email spares stoddart co nz www stoddart com au Australian Business Number 16009690251 Australia Sales Tel 1300 79 1954 Email sales stoddart com au Service Spare Parts Tel 1300 307 289 Email service stoddart com au Email spares stoddart c...