Rev 10.1/8-20
3
PF-89DCO-DVS: #35132
SPECIFICATIONS
Description:
Designed for use with a crane or other hoisting equipment, PF-89DCO lifters employ
vacuum to hold a load for lifting, and they provide manual 180° rotation and manual
90° tilt movements for load manipulation.
Model Number:
PFHS89DCO
PFHL89DCO
Maximum Pad Spread:
39¼" x 47"
39¼" x 59½"
(to outer edges)
[994 mm x 1197 mm]
[994 mm x 1513 mm]
Maximum Load Capacity: (rated at 16" Hg [-54 kPa] on clean, smooth, nonporous flat surfaces
1
)
Per-Pad:
125 lbs [57 kg]
Total:
1000 lbs [455 kg]
Lifter Weight:
130 lbs [59 kg] (for larger configuration)
Power System:
12 volts DC, 10 amps
Battery Run-Time:
7 amp-hours
Vacuum Pads:
Eight 9" [23 cm] nominal diameter (Model VPFS9), standard rubber, spring-mounted
(¼" [7 mm] travel), with #60 filter screen
Rotation Capability:
Manual, 180°, with automatic locking at each ¼ revolution (when desired)
Tilt Capability:
Manual, 90°, with automatic locking in vertical position
Vacuum Pump:
Diaphragm type, 1 SCFM [28 liters/minute] nominal airflow
Vacuum Reserve Tanks:
Vacuum reservoirs help prevent immediate vacuum loss in case of power failure and
extend battery life by reducing pump cycles required to maintain vacuum.
Vacuum Gauges:
Dial gauges indicate current vacuum level in positive inches of Hg and negative kPa.
Low Vacuum Warning Light: Red light is energized until vacuum level is sufficient to lift maximum load weight
(higher than 16" Hg [-54 kPa]) and whenever vacuum loss causes pump to re-engage.
Low Vacuum Warning Buzzer: Maximum Alarm Volume = 103 dBA at 2 ft [60 cm]. While the lifter is powered
up, an audible alarm warns the operator whenever vacuum is not sufficient for lifting
the maximum load weight.
Options:
Dual Vacuum System. Two vacuum system circuits allow the lifter to maintain the
vacuum level in one circuit even if an unexpected vacuum loss occurs in the other one
(eg, due to load breakage). See separate instructions about other options.
Operating Elevation:
Maximum = 6000 feet [1828 meters]
Operating Temperatures: 32° to 104° F [0° to 40° C]
Service Life:
This lifter is designed to have a service life of at least lifting cycles, when used and
maintained as intended. Vacuum pads, filter elements and other wear-out items are
excluded; see MAINTENANCE and REPLACEMENT PARTS LIST for more information.
For the D
ISPOSAL OF THE
L
IFTER
after its service life, see INTENDED USE.
ASME Standard BTH-1:
Design Category "B", Service Class "0" (see www.wpg.com for more information)
!!‒CE‒!! Note: This symbol appears in the
INSTRUCTIONS
manual only when requirements of a CE Standard are
different
from
requirements of other standards that also apply to this vacuum lifter. CE requirements are mandatory in geographical areas
where CE Standards apply, but may be optional in other locations.
1
Maximum Load Capacity is based on a friction coefficient of 1; see MAINTENANCE: V
ACUUM
P
AD
M
AINTENANCE
: Friction
Coefficient for additional information.