Rev 27.3/8-20
3
PF-DC: #35131
SPECIFICATIONS
Model Number:
8 Vacuum Pads
Vertical Configuration:
―
Horizontal / Small Configuration:
PFHS89DC
Horizontal / Large Configuration:
PFHL89DC
Maximum Pad Spread: (to outer edges)
Vertical Configuration:
―
Horizontal / Small Configuration:
39½" x 47½" [1006 x 1209 mm]
Horizontal / Large Configuration:
39½" x 59½" [1006 x 1514 mm]
Lifter Weight: (for larger configurations)
6 Vacuum Pads
PFV69DC
PFHS69DC
PFHL69DC
57½" x 46½" [1463 x 1184 mm]
37½" x 46½" [955 x 1184 mm]
46½" x 57½" [1184 x 1462 mm]
100
lbs [4
6
kg]
130 lbs [59 kg]
Load Capacity: (rated at 16" Hg [-54 kPa] on clean, smooth, nonporous flat surfaces
1
)
Per-Pad:
125 lbs [56.5 kg]
125 lbs [57 kg]
Maximum:
700 lbs [320 kg]
1000 lbs [455 kg]
Description:
Designed for use with a crane or other hoisting equipment, PF-9DC lifters employ
vacuum to hold a load for lifting, and they provide manual 180° rotation and manual
90° tilt movements for load manipulation.
Power Source:
12 volts DC, 10 amps (with Thomas pump) or 3.5 amps (with Dynaflo pump)
Battery Capacity:
7 amp-hours
Vacuum Pads:
9" [23 cm] nominal diameter (Model VPFS9), standard rubber, spring-mounted (¼" [7
mm] travel), with #60 filter screen
Rotation Capability:
Manual, 180°, with automatic locking at each ¼ revolution (when desired)
Tilt Capability:
Manual, 90°, with automatic locking in vertical position
Vacuum Pump:
Diaphragm type, 1 SCFM [28 liters/minute] nominal airflow
Vacuum Reserve Tank:
Vacuum reservoir helps prevent immediate vacuum loss in case of power failure and
extends battery life by reducing pump cycles required to maintain vacuum.
Vacuum Gauge:
Dial gauge indicates current vacuum level in positive inches of Hg and negative kPa.
Low Vacuum Warning Light: Red light is energized until vacuum level is sufficient to lift maximum load weight
(higher than 16" Hg [-54 kPa]) and whenever vacuum loss causes pump to re-engage.
Low Vacuum Warning Buzzer (if applicable): Maximum Alarm Volume = 103 dBA at 2' [60 cm]. While lifter is
powered up, audible alarm warns the operator whenever vacuum is not sufficient for
lifting the maximum load weight.
Options:
See separate instructions about optional features.
Operating Elevation:
Maximum = 6,000' [1,828 m]
Operating Temperatures: 32° to 104° F [0° to 40° C]
Service Life:
This lifter is designed to have a service life of 20,000 lifting cycles, when used and
maintained as intended. Vacuum pads, filter elements and other wear-out items are
excluded; see MAINTENANCE and REPLACEMENT PARTS LIST for more information.
For the D
ISPOSAL OF THE
L
IFTER
after its service life, see INTENDED USE.
ASME Standard BTH-1:
Design Category "B", Service Class "0" (see www.wpg.com for more information)
!!‒CE‒!! Note: This symbol appears in the
INSTRUCTIONS manual only when requirements of a CE Standard are different from requirements of other
standards that also apply to this vacuum lifter. CE requirements are mandatory in geographical areas where CE Standards apply, but may be optional in
other locations.
1
Load Capacity is based on a friction coefficient of 1; see MAINTENANCE: V
ACUUM
P
AD
M
AINTENANCE
: Friction Coefficient for
additional information.