Sawmill Setup
IMPORTANT!
Before starting to use the sawmill you have to meet the
following conditions:
Set up the sawmill on firm, level ground and level the sawmill. Secure the sawmill to the ground to
prevent moving during operation. A concrete foundation or pads (rated to support 31 T/m
2
at each
sawmill foot position) and 16 mm anchored bolts are recommended.
Under roof, the sawmill can be operated with the sawdust collection system only.
The sawmill can’t be operated outdoor when it is raining/snowing and in case of rain/snow the
sawmill must be stored under roof or indoor.
The sawmill can be operated in temperature range from -15
o
C to 40
o
C only (AC sawmills).
The illumination at the operator's position should be at least 300lx.
The sawmill operator’s position is shown below.
Have a qualified electrician install the power supply (according to EN 60204 Standard). The power
supply must meet the specifications given in the table below.
3-Phase
Volts
Fuse disconnect
Suggested Wire Size
400 VAC
40 A
6 mm
2
up to 15 m long
TABLE 2-0
!