REMOTE WALL MOUNTED SWITCH
A remote wall switch and up to fifteen (15) feet of 18 Ga. wire may be used with this appliance. Attach the wall switch in a junc-
tion box at the desired location on the wall.
See Figure 35
. Do not extend beyond the wall switch wire length provided.
NOTE:
Extended lengths of wire may cause the fireplace not to function properly. Longer length of wire is permitted
if the wire is made out of larger gauge (diameter) wire. Always check with local code.
Figure 35 - Wiring Diagram for Wall Switch
THE WALL SWITCH OR WALL THERMOSTAT MUST BE CONNECTED
NEVER
TO ANY EXTERNAL POWER SUCH AS HOUSEHOLD 110V CIRCUIT!
DANGER!
THERMOSTAT
ELECTRICAL INSTALLATION
GLASS FRAME
INSTALLATION
GLASS
REM
Glass Frame
spring
washer
nut
O
washer
FIREBOX
Figure - Glass Frame
Threaded studs
(typical for 8 locations)
Spring and nut assembly
(typical for 8 locations)
IMPORTANT:
Adjust the nuts so the tips of the studs are
exposed by 1/8" ( 8 locations).