Neutral cleaner

When there is dirt on the nozzle, maintain it according to the following methods: 

1. When no one is seated, turn the knob forward (press Rear Cleaning Button on the main unit), then nozzle rod 

    is extended, and manually clean with a rag or soft brush.

2. Nozzle can be removed and cleaned separately. (Hold the nozzle rod in one hand and pull the nozzle out with 

    the other hand)

3. Put back the nozzle, and then press the knob button (Stop button) on the main unit or the "Stop" button on the 

    remote control, the guided rod retracts.

       

Filter Maintenance

Tips: Do not pull the nozzle rod to prevent the damage of the nozzle rod and  motor.

Maintenance of Main Unit

Daily Maintenance

1.Turn off the power during maintenance of this machine.

2. Wipe the dirty area with a soft cloth that is wrung out of water.

3. After wiping, please turn on the power again.

Tips: Do not rinse the surface of the product directly with water 

         during maintenance.

Maintenance of the Nozzle

Time for maintenance: It is under normal 

water pressure but poor flush performance 

occurs.

1. Turn off the angle valve.

2. Unscrew toilet water inlet pipe and seat  

    water inlet pipe.

3. Take out filter and filter washer

4. Brush filter with toothbrush and clean filter

5. Re-install filter and filter washer, then 

    re-install water inlet pipe

3-way 

connector 

 The filter

(Remove with 

 a nipper pliers)

Filter 

washer

Connect to toilet 

water supply pipe

Connect to seat water 

inlet pipe

www.woodbridgebath.com

10

Summary of Contents for BID 02

Page 1: ...ore installation and keep it available for future maintenance or reference Our company reserves the right of final interpretation for this manual The manual is subject to change without notice Custome...

Page 2: ...wer plug must be switched off and water supply be shut off WARNING To reduce the risk of burns electrocution fire or injury to persons 1 Close supervision is necessary when this product is used by on...

Page 3: ...the room temperature is under zero degree please dry up the water tank to avoid freezing 15 Raise rest room temperature to prevent the toilet from damage due to freezing 16 When move the product from...

Page 4: ...e 200W High temperature preventer thermal fuse If Applicable 6 level adjustment Over 0 2m min Warm wind speed Warm wind temperature Heating power Safety device Drying device Technical Specification No...

Page 5: ...protection plug Whole set of product Power cord Infrared receiver Nozzle baffle Nozzle The remote control Buffer Lid Components Name Seat Release button Drying baffle Water supply pipe Front cleaning...

Page 6: ...ne step 1 Long press Stop Button to make the main unit enter standby mode press Stop Button again to make the main unit return to Operating mode In standby mode all functions are invalid by pressing a...

Page 7: ...nut 4 Expansion nut 2 Manual including warranty card Remote control Remote control rack The remote control assembly Base plate assembly The filter assembly Certificate of quality Certificate of quali...

Page 8: ...not put it in a place prone to water Install Base plate Toilet mounting holes IInstall Mounting Cardboard The black latch faces Forward Groove up Install the expansion nuts into the toilet mounting h...

Page 9: ...Connect to the angle valve Connect to main unit Connect Tee joint to angle valve The original Tee joint should be removed Connect the inlet end of water supply pipe to Tee joint according to the above...

Page 10: ...ge Turn the angle valve counterclockwise to adjust the opening to the maximum Tips when the valve is opened for the first time the angle valve handle has a large torque 2 Power Connection Insert power...

Page 11: ...motor Maintenance of Main Unit Daily Maintenance 1 Turn off the power during maintenance of this machine 2 Wipe the dirty area with a soft cloth that is wrung out of water 3 After wiping please turn o...

Page 12: ...e power 3 Remove the seat press current limiting shaft in the middle with a flat blade screwdriver then reinstall the seat and open the inlet valve 4 If there is still no water coming out after pressi...

Page 13: ...retch out Remote control cannot display Malfunction of deodorization Caution The wind temperature is set in normal temperature level In standby mode or power saving mode Power off Get stuck by impurit...

Page 14: ...INSTALLER S NAME PLUMBER CONTRACTOR LICENSE INSTALLER INFORMATION NOTES DATE OF INSTALL INSTALLER S NAME PLUMBER CONTRACTOR LICENSE INSTALLER INFORMATION Customer Service Phone 562 229 0088 Monday Fr...