Phoenix Installation
and Operation Manual
PG
9
OF
40
M0029.09 SEPTEMBER 2017
An ongoing program of product improvement may
require us to change specifications without notice.
WOOD STONE CORPORATION
1801 W. Bakerview Rd.
Bellingham, WA 98226 USA
TEL
+1.360.650.1111
FAX
+1.360.650.1166
woodstone-corp.com
INSTALLATION CLEARANCES
CLEARANCES
a.
The Wood Stone Phoenix oven must have a
minimum 25 mm (1") clearance to combustibles from all sides, 152 mm
(6") clearance to combustibles from the top and 152 mm (6") from the flue collar.
If building a facade that will contact
the oven, use completely non-combustible materials� Any facade wall built 152 mm (6") to either side of the doorway or
above must be of non-combustible construction� Please note that standard Drywall (or Sheetrock) is considered a limited
combustible� Any walls perpendicular to the front of the oven in the area 762 mm (30") to either side of the doorway and 914
mm (36") in front of the oven should have a non-combustible surface�
b.
The oven must be installed on a non-combustible floor surface� The non-combustible floor surface must extend 914 mm
(36") in front of and 914 mm (30") to either side of the oven doorway�
!
WARNING:
Installation and servicing of this product could expose you to glasswool/ceramic fibers as well as
calcium silicate dust� ALWAYS WEAR RESPIRATORY AND EYE PROTECTION WHEN INSTALLING OR SERVICING
THIS APPLIANCE� Please read this entire manual before you install the oven� Failure to follow instructions
may result in property damage, bodily injury or even death� Contact your local building or fire officials about
restrictions and installation inspection in your area�
!
WARNING: Do not pack required air space (clearance) with insulation or other materials. When non-
combustible building materials contact the body of the oven, the clearances to combustibles are
transferred to those non-combustibles.
Maintain 152 mm
(6") clearance from
the flue outlet
Ruled area (152 mm (6")
to either side of doorway
and above) represents
space where facade
materials must be non-
combustible.
Hatched area must
be left accessible and
unobstructed after
installation for air intake
and routine service of the
oven burner.
25 mm (1")
minimum side
clearance to
combustible
construction
Non-combustible floor,
914 mm (36") in front
and 762 (30") mm
to either side of
oven doorway