Questions? Call Wood Stone at 800-988-8103
7
RFG-IR-W Oven Installation and Operation Manual
April 2005
GAS
The Wood Stone Gas ovens are equipped with a 3/4" NPT gas
connection. Have a licensed gas installer provide the hook-up and test
all fittings and pipe connections for leaks. Use approved gas leak
detectors (soap solutions or equivalent) over and around the fittings and pipe
connections. DO NOT USE FLAME TO TEST FOR LEAKS!
SV-1 and SV-2 are the gas control valves that operate under floor
infrared burner and the interior radiant burner, respectively. SV-1 is located
directly behind the service/ intake panel and in front of the under floor infrared
burner. SV-2 is located under the oven to the rear left.
The manifold pressure test port for the infrared under floor
burner is a 1/8" NPT plugged tapping located near the left end of the
burner manifold.
The manifold pressure test port for the radiant (interior) burner is
a 1/8" NPT plugged tapping located at the base of the T-junction between
the SV-2 and the radiant/interior burner. When checking this pressure,
make sure the flame is turned up to its maximum height using the knob
on the front of the oven.
The burner manifold pressures have been adjusted and tested at the factory. A variety of
factors can influence these pressures, so be sure to test the individual burner manifold pressures
and adjust the valves as necessary to achieve the required pressures. Note: The gas valves
are shipped in the 'on' position.
Factory specified individual burner manifold pressures for models
equipped to burn Natural Gas.
MODEL
SV-1 SV-2
WS-MS-4-RFG-IR-W-NG
3.5" 5"
WS-MS-5-RFG-IR-W-NG
3.5" 4.75"
WS-MS-6-RFG-IR-W-NG
3.5" 4.75"
WS-MS-7-RFG-IR-W-NG
3.5" 4.6"
Factory specified individual burner manifold pressures for
models equipped to burn Propane (LP).
MODEL
SV-1 SV-2
WS-MS 4-RFG-IR-W-LP
9"
7"
WS-MS-5-RFG-IR-W-LP
9"
8"
WS-MS-6-RFG-IR-W-LP
9"
8"
GAS SPECIFICATIONS
WS-MS-7-RFG-IR-W-LP 9.2" 9.5"