![Wood-mizer LT70-R Safety, Operation, Maintenance & Parts Manual Download Page 23](http://html1.mh-extra.com/html/wood-mizer/lt70-r/lt70-r_safety-operation-maintenance-and-parts-manual_994570023.webp)
Accuset 2 Troubleshooting
Control Lights (Single-Axis)
Accuset 2 Troubleshooting
60AS2-R07doc032519
2-3
2
2.2
Control Lights (Single-Axis)
LT70HD Remote
prior to Rev. B3.00
Lights are provided on the control front panel and the motor control assembly (located in
the remote power box) to help diagnose up/down problems should they occur.
See Figure 2-3.
Two indicator lights are provided on the back of the front control panel. If
power is supplied to the control panel, the red power indicator light will be illuminated.
The drum switch indicator illuminates when the up/down drum switch is engaged. The
light will illuminate green with the drum switch in the up position and red with the drum
switch in the down direction.
FIG. 2-3
SM0341
Power Indicator
Drum Switch Indicator