Wonderfire Gasflame 3 639 GFC Installer'S Manual Download Page 6

INSTALLER’S GUIDE

Page

 

5

Suitable flues and minimum flue sizes are as follows: -
a)

 

225mm x 225mm conventional brick flue.

b)

 

175mm diameter lined brick or stone flue.

c)

 

200mm diameter factory made insulated flue manufactured to BS4543.

d)

 

175mm diameter flue pipe. See BS6461 Part 1 for suitable materials.

e)

 

A masonry chimney having a correctly installed flexible flue liner with

minimum diameter of 125mm and conforming to BS715.

The minimum effective height of the flue must be 3m.

The flue must not be used for any other appliance or application.
Any chimney damper or restrictor should be removed. If removal is not possible,
they must be secured in the open position.
If the appliance is intended to be installed to a chimney that was previously used for
solid fuel, the flue must be swept clean prior to installation. All flues should be
inspected for soundness and freedom from blockages.

Figure 1. Hearth and Fireplace Opening

Summary of Contents for Gasflame 3 639 GFC

Page 1: ...ANE GAS G31 THIS APPLIANCE IS FOR USE IN THE UNITED KINGDOM GB AND THE REPUBLIC OF IRELAND IE ONLY We trust that these instructions give sufficient details to enable this appliance to be installed and...

Page 2: ...Standards Wonderfire is a member of the Society of British Gas Industries which works to ensure high standards of safety quality and performance Careful Installation Wonderfire is a CORGI registered...

Page 3: ...further with the installation of this appliance please read the following guide to manual handling The lifting weight of this appliance is 9 6 kg One person should be sufficient to lift the fire If fo...

Page 4: ...6in 9800122 Charcoal Black 16in 9800123 Blenheim Firefront Fret Brass effect 16in 9800040 Antique Black Brass effect 16in 9800075 Chrome effect 16in 9800076 Black Cast Iron with Brass Finials 16in 980...

Page 5: ...2 BS 5440 Part 1 BS 5440 Part 2 BS 5871 Part 3 BS 6461 Part 1 BS 6891 BS 8303 d In England and Wales the current edition of the Building Regulations issued by the Department of the Environment and the...

Page 6: ...e liner with minimum diameter of 125mm and conforming to BS715 The minimum effective height of the flue must be 3m The flue must not be used for any other appliance or application Any chimney damper o...

Page 7: ...stone etc should be rectified The base of the fireplace opening must be level with the top surface of the hearth There should be no gaps between the hearth and the fireplace opening 3 4 1 Hole in the...

Page 8: ...when close to a heating appliance Please bear this in mind when installing 3 9 This appliance must not be installed in any room that contains a bath or shower or where steam is regularly present 3 10...

Page 9: ...ilable 3 12 Propane gas appliances must not be installed in a room that is built entirely below ground level see BS 5871 Part 3 3 13 If the appliance is to be fitted against a wall with combustible cl...

Page 10: ...l the listed parts are present and in good condition 5 INSTALLATION OF APPLIANCE 5 1 Fireplace size The fireplace must comply with the requirements described in section 3 5 2 Fireplace flue pull Visua...

Page 11: ...front flange see figure 4 It is important that there are no gaps between the joints 2 Position the remaining length of foam seal along the front edge of the base Make sure that the whole length of th...

Page 12: ...the appliance finishes centrally in the opening when tension is applied to the cables 3 Insert a fibre plug into each hole Use the fibre plugs supplied with this appliance Never use plastic plugs ins...

Page 13: ...ng the hexagonal adjusters by hand See figure 10 10 Inspect the installation of the convector box against the fireplace surround If the convector box is aligned squarely and the sealing is satisfactor...

Page 14: ...urner assembly in position against the convector box bottom location bracket See figure 12 Secure using the screw removed previously 5 5 Burner and supply pipe installation There are three grommets to...

Page 15: ...place opening If the smoke is not drawn into the fireplace opening leave the appliance alight at the maximum setting for a further ten minutes and then repeat the test If smoke is still not drawn into...

Reviews: