15
Securing firebox to wall -
cable retention
Assemble retention cables into firebox.
Insert cables into cable anchor points in
upper rear of firebox and then tape
together adjoining edges of the jacket as
shown in figure 16. Offer the firebox up
to the wall and feed the retention cable
through the installed eyebolts.
Return the cables through the holes
provided at the lower back of the firebox.
Assemble adjusters and tension as in
figure 17
.
Securing firebox to wall using
fixing brackets
Loose assemble the two fixing brackets
provided (see figure 18) using the screws
provided. Offer fire up to wall.
Establish the final location of firebox,
and secure fixing brackets accordingly.
Mark off the wall, drill two holes using
no.10 drill bit. Insert wall plugs. Firebox is now ready to secure using wood
screws provided.
Fig. 18
Fig. 17