5
Figure 3
Figure 4
8mm (5/16) Bundy or semi-rigid tubing must be used to connect the appliance to the
gas supply.
Centre the burner tray in the fireplace opening with the tray as far to the rear as
possible. Secure the burner in position and fix through the centre front leg into the
hearth using a heatproof wall plug and
fixing screw (supplied). Purge the gas
supply and make the connection to the
control. Test all joints for gas soundness.
Attach a manometer to the pressure test
point (see figure 2a) and follow the lighting
procedure to establish the pilot and then
turn to maximum setting. Check the gas
pressure against the setting pressures
(see gas data).
Turn off the fire and allow to cool.
COMMISIONING THE BURNER
Placing the front coal
Remove both front coal pieces from the protective packaging and position in front of
the burner as shown in figure 3.
The retaining tags may be adjusted
in order to ensure secure fitting of
the front coal.
Placing the fuel matrix
Remove the fuel matrix from its
protective packaging and position
on top of the burner as shown in
figure 4. The rear face of the burner
should locate into two cut-outs on
the top face of the rear legs. Ensure
that the matrix sits flatly on the top
of the burner.
Figure