Maximum Length of Single Strand Wire
15 Miles
Voltage
6v, 9v and 12v
Peak Joules Output
0.35 - 0.60
Power Consumption
48mA to 80mA
Output No Load
5000v to 8000v
Output Light Load (5000 Ohms)
4500v to 7500v
Output Heavy Load (500 Ohms)
2200v to 3500v
Guarantee
2 Years
DISPOSAL AND RECYCLING INFORMATION
Thank you for purchasing the Wolseley BX140 Energiser. Please familiarise yourself with the operator instructions for
your product and always use only for the purpose it was designed. At any point in the future, should you decide to
dispose of or replace your product, please ensure that you do NOT dispose of it in a Landfill site. Please only dispose
of it at a registered recycling facility. More information can be found at WWW.RECYCLE-MORE.CO.UK. Also please
ensure that any batteries where fitted are removed and recycled in the correct manner.
For any further advice on recycling our products, please contact our UK Service
Department on 01392 460077, who will be pleased to help.
W.E.E. Registration Number: WEE/GGO133ZR/PRO
Safety Requirements and Regulations
Electric fences shall be installed and operated so that they cause no electrical hazard to persons, animals or their surroundings. Electric
fence constructions which are likely to lead to entanglement of animals or persons shall be avoided.
An electric fence shall not be supplied from more than one energiser or from independent fence circuits of the same energiser.
The gap between two separate electric fences with different energisers shall be at least 2 metres. If this gap is to be closed, this should be
affected by means of an electrically non conductive material. Barbed or razor wire shall not be elctrified by an energiser.
Any part of an electric fence which is installed along a public path or highway shall be identified by warning signs (p/no 33020) securely
fastened to the fence posts or firmly clamped to the fence wires at intervals recommended to be of approximately 10 to 50 metres, but not
exceeding 90 metres. The warning signs shall be at least 100 x 200mm. The background colour or both sides shall be yellow. The
inscription shall be black and shall be the substance of TAKE CARE - ELECTRIC FENCE. The inscription shall be indelible, inscribed on
both sides and have a height of at least 25mm.
Except for low output battery operated energisers, the energiser earth electrode shall penetrate the ground to a depth of at least 1m.
Connecting leads that are run inside buildings shall be effectively insulated from the earth structural parts of the building. This may be
achieved by using double insulated high voltage cable (p/no 31640).
Connecting leads that are run underground shall be run in a conduit of insulating material.
Care shall be taken to avoid damage to the connecting leads due to the effects of animal hooves or tractor wheels sinking into the gound.
Connecting leads shall not be installed in the same conduit as the mains supply wiring, communication cables or data cables.
If connecting leads and electric fences are installed near an overhead power line the clearance shall be:
1. Power line voltage: Under 1,000 volts
Clearance: 3 metres
2. Power line voltage: 1000 to 33,000 volts
Clearance: 4 metres
3. Power line voltage: Over 33,000 volts
Clearance: 8 metres
If connecting leads and electric fence wires are installed near an overhead power line, their height above ground shall not exceed 2 metres.
This height applies either side of the orthogonal projection of the outermost conductors of the power line on the ground surface, for a
distance of 2m for power lines not exceeding 1,000v and 15m for power lines exceeding 1,000v.
A distance of 10m shall be maintained between the energiser and any other earth system such as the household supply system protective
earth or the telecom earth system.
A warning sign as described earlier shall be fitted to every point where persons may gain ready access to the conductors.
Where an electric animal fence crosses a public pathway, a non-electrified gate shall be incorporated in the electric fence at that point or a
crossing by means of stiles shall be provided.
At any such crossing, the adjacent electrified wires shall carry warning signs as described earlier.