WolfVision VZ-C122 Instructions Manual Download Page 17

The software (firmware) of your Visualizer (including the o

) can easily be 

upgraded to the latest version. The firmware update can be done via USB, Ethernet (LAN) 
or RS232.

Firmware update files can be downloaded for free at 

www.wolfvision.com/support

Updates via USB can be made with the WolfVision USB Software, updates via 
Ethernet/LAN require the WolfVision Ethernet Software and updates via RS232 can be 
made with WolfVision's Firmware Update Utility. All three programs can also be found on 
our homepage.

For RS232 connection, use a crossed serial RS232 cable (Nullmodem-cable).

n-screen HELP

Firmware Upgrades

Dimensions

92

90

7

2

1

2

5

,5

2

0

6

Closed:

Open:

Ceiling mount

Cooling
Air Inlet

Cooling

Air Outlet

All measurements in millimeters (for inch see list)

5

7

,1

135

1

6

0

8

0

160

8

0

4

0

70

6

0

1

2

18

95

3

5

2

452

400

2

8

5

mm

12

0.47

18

0.71

40

1.57

58,1

2.29

60

2.36

70

2.76

72

2.83

80

3.15

90

3.54

92

3.62

95

3.74

125,5

4.94

135

5.31

144

5.67

160

6.3

206

8.11

240

9.45

285

11.22

352

13.86

390

15.35

400

15.75

452

17.8

528

20.79

IMPORTANT NOTE: 

DO NOT BLOCK 

COOLING AIR 

INLET AND 

OUTLET!

Inch

MAINTENANCE

The Ceiling Visualizer is fitted with an automatic lamp changer. 
If one lamp fails, there is no need to replace it immediately, as the automatic lamp changer 
automatically switches to the second

 

(spare) lamp. When the unit changes

 

lamps there is 

an on-screen message saying: "Changing lamp".
When switching on the unit the Visualizer checks if both lamps are working. If one lamp fails 
there will be an

 

on screen message for a couple of seconds displaying "Lamp x blown". 

This prevents a user from forgetting to change a defective lamp.

Automatic Lamp Changer

If the unit gets too hot (improper ventilation or air extraction) a built in thermostat will switch 
off the light of the Visualizer. Verify that proper ventilation and air extraction is available and 
allow the unit to cool.

Thermostat

16

5

2

8

70

°

240

1

4

4

160

R

39

0

R9

0

Summary of Contents for VZ-C122

Page 1: ...Check out our Internet Homepage for additional information www wolfvision com support VZ C12 VZ C32 VZ C12 VZ C32 INSTRUCTIONS BEDIENUNGSANLEITUNG INSTRUCTIONS BEDIENUNGSANLEITUNG ENGLISH DEUTSCH R...

Page 2: ...NDS CLEAR LOCKOUT BEFORE SERVICING USE THIS UNIT ONLY WITH THE CORRECT VOLTAGE AS SHOWN ON THE TYPE LABEL DO NOT EXPOSE THE UNIT TO HEAT OR MOISTURE PROTECT THE UNIT FROM EXCESSIVE SHOCKS Make sure th...

Page 3: ...rding to Directive EMC and to Directive electrical equipment Inspections tests and evaluation are according to UL 60950 CSA 22 22 60950 Inspections tests and evaluation are according to the CB Scheme...

Page 4: ...20 21 22 23 24 25 18 26 15 T3 15A 14 Connectors 10 and Main Switch 7 12 Main Power Switch beside the glass cover 13 Power Indication LED beside the glass cover 14 Fuses see page 18 15 Power Connectio...

Page 5: ...27 36 29 30 31 32 33 34 35 38 37 40 41 39 MENU POWER TELE WIDE LASER EXT INT ALL TEXT FOCUS IRIS 1 2 3 A A A A AF MEMORY 1 2 3 4 5 6 7 8 9 HELP PRESETS IMAGE TURN LIGHT 28 Infrared Remote Control 6 4...

Page 6: ...specialists The overall iris level can be changed in the on screen menu see page 15 33 Light key Switches the light on and off see page 8 By pressing the LIGHT key for 2 seconds an one push white bala...

Page 7: ...automatic setting of zooming to an middle zoom position pick up size depends on mounting height of the Visualizer focus on the working surface level and the auto iris are activated As soon as the Pow...

Page 8: ...e size of the smallest and largest image that the unit can pick up is not fixed It depends on the distance between the working surface and the bottom of the Visualizer The tables in the installation m...

Page 9: ...If the top light of the Visualizer is used default a synchronized lightfield always marks the pick up area of the built in camera on the working surface The alignment of this lightfield is made for w...

Page 10: ...RIS keys 32 the auto iris function is switched off In this mode the Iris can be adjusted manually When using the ZOOM keys 27 the auto iris function is switched on again Before the iris closes complet...

Page 11: ...9 quickly By pressing the All key 36 a split image with all 9 pictures of the memory can be displayed When pressing the ALL key 36 for 4 seconds a menu appears on the screen asking if you would like t...

Page 12: ...example if changing between Visualizer s light and an external lightbox bottom light or if room light is turning on or off The standard settings of the Visualizer are the following When the Visualizer...

Page 13: ...lizer to match the native resolution of your display unit e g LCD or DLP projector or monitor Important What matters is the native resolution of the projector or monitor not the maximum resolution tha...

Page 14: ...0 port This allows uploading images onto a PC in a fraction of a second Connecting slower computers with the older USB 1 1 standard is also no problem It still takes only a small fraction of the time...

Page 15: ...nc C2 Analog Green C3 Analog Blue C5 Analog Ground not used analog R G B return m Pin 24 Pin 8 Pin 1 Pin 9 Pin 17 C4 C1 C2 C3 C5 The S video Y C 21 and Composite 17 video outputs can be switched betwe...

Page 16: ...lizer firmware In the Power Control settings of the on screen menu you can select that the Visualizer will be automatically switched off after a certain amount time If the picture or the colors on you...

Page 17: ...0 2 76 72 2 83 80 3 15 90 3 54 92 3 62 95 3 74 125 5 4 94 135 5 31 144 5 67 160 6 3 206 8 11 240 9 45 285 11 22 352 13 86 390 15 35 400 15 75 452 17 8 528 20 79 IMPORTANT NOTE DO NOT BLOCK COOLING AIR...

Page 18: ...controlled at all with the infrared remote control you may have to change the batteries Open the cover on the back of the remote control and replace the two 1 5 V AA batteries with new ones Check the...

Page 19: ...to avoid burning fingers When inserting a new lamp into the socket use a cloth to prevent fingerprints on the lamp figure 1 release button Disconnect the power cord 15 before changing the fuses The f...

Page 20: ...p area of camera with 4 3 16 9 switching yes yes yes via USB serial RS232 or Ethernet LAN two telezoom lenses 64x Zoom 16x optical 4x digital no limit depending on installation height depending on ins...

Page 21: ...make sure that you pack up the Visualizer in the supplied box as explained in this graphic This is very important to avoid damage to sensitive parts of the unit IMPORTANT Packaging Transportation 20 3...

Page 22: ...push auto focus Press both FOCUS keys 31 simultaneously Filling the memory quickly Press the ALL key 36 for more than 4 seconds Then follow the instructions of the on screen menu Press MEMORY 1 39 fo...

Page 23: ...st L ftungsschlitze links und rechts unbedingt freihalten Bei jeder Art von St rungsanzeichen abnormale Ger usche Geruch Rauchentwicklung etc das Ger t abschalten Setzen Sie sich bitte in solchen F ll...

Page 24: ...urchgef hrt Pr fungen Tests und Untersuchungen wurden nach dem PCT Schema durchgef hrt Aufkleber am Ger t Pr fungen Weltweite Patente Copyright Information Copyright WolfVision Alle Rechte vorbehalten...

Page 25: ...se und Hauptschalter 12 Hauptschalter Netz neben dem Abdeckglas 13 Power LED zur Anzeige des Betriebsstatus neben dem Abdeckglas 14 Sicherungen siehe Seite 18 15 Netzanschluss 16 RGB Ausgang 15 pin si...

Page 26: ...27 36 29 30 31 32 33 34 35 38 37 40 41 39 MENU POWER TELE WIDE LASER EXT INT ALL TEXT FOCUS IRIS 1 2 3 A A A A AF MEMORY 1 2 3 4 5 6 7 8 9 HELP PRESETS IMAGE TURN LIGHT 28 Infrarot Fernbedienung 4...

Page 27: ...n siehe Seite 15 33 LIGHT Taste Schaltet das Licht aus und ein siehe Seite 8 Durch Dr cken der LIGHT Taste f r 2 Sekunden wird ein One Push Wei abgleich durchgef hrt siehe Seite 11 34 TEXT Enhancement...

Page 28: ...ion auf der Arbeitsfl che die Aufnahme gr e ist abh ngig von der Montageh he des Visualizers Sobald die POWER LED 26 durchgehend gr n leuchtet ist der Visualizer betriebsbereit Das Verhalten des Ger t...

Page 29: ...des Ger tes an der Decke durch Die Bildgr en die das Ger t aufnehmen kann sind nicht fix Sie sind abh ngig vom Abstand zwischen der Arbeitsfl che und der Unterseite des Visualizers Die Tabelle in der...

Page 30: ...tbox optional Arbeitsplatte Lichtbox Bei Verwendung des Visualizer Lichtes markiert ein synchronisiertes Lichtfeld den Aufnahmebereich der eingebauten Kamera auf der Arbeitsfl che Das Lichtfeld dient...

Page 31: ...igen der IRIS Tasten 32 wird die Auto Iris Funktion abgeschaltet und somit kann die Iris manuell bedient werden Durch bet tigen einer der ZOOM Tasten 27 wird die Auto Iris Funktion wieder eingeschalte...

Page 32: ...alle 9 Bildspeicher durch Snapshots zu f llen dr cken Sie die ALL Taste 36 f r 4 Sekunden bis eine Auswahl im Bild erscheint Hier kann zwischen Snapshot und erase l schen gew hlt werden Wenn Sie Snap...

Page 33: ...chtbox gewechselt wird oder wenn die Raumbeleuchtung ein bzw ausgeschaltet wird Die Standardeinstellungen des Visualizers sind folgende Wenn das Licht des Visualizers eingeschaltet ist fixer Wei abgle...

Page 34: ...r des DLP Chips Ihres Projektors oder Monitors Die meisten LCD oder DLP Projektoren k nnen auch h here Bildaufl sungen welche ihre tats chliche Pixel Anzahl berschreiten darstellen jedoch nur im kompr...

Page 35: ...Auch langsamere Computer mit dem lteren USB 1 1 Standard k nnen problemlos verwendet werden Auch hier wird nur ein Bruchteil der Zeit ben tigt die ein Desktop Scanner braucht um ein Bild einzulesen Wo...

Page 36: ...echselt der Decken Visualizer automatisch von One Push Wei abgleich auf Auto Tracking Wei abgleich fortlaufende automatische Einstellung des Wei wertes Damit wird die Farbtemperatur unterschiedlicher...

Page 37: ...funktion aktiviert werden Sobald der Visualizer f r die Dauer der voreingestellten Zeit nicht benutzt wird schaltet er automatisch in den Bereitschaftsmodus Standby Falls Ihnen das Bild auf Ihrem Bild...

Page 38: ...ss diese nicht sofort ersetzt werden Durch den automatischen Lampenwechsler schaltet das Ger t automatisch auf die zweite Lampe Ersatzlampe um W hrend diesem Vorgang erscheint die Meldung Changing Lam...

Page 39: ...der Fernbedienung zu steuern ist m ssen meist nur die Batterien ersetzt werden ffnen Sie h ndisch die Abdeckung der Fernbedienung auf der R ckseite und ersetzen Sie beide 1 5V AA Batterien durch neue...

Page 40: ...assen um Verbrennungen zu vermeiden Beim Einsetzen einer neuen Lampe Fingerabdr cke am Lampenkolben vermeiden Netzkabel 15 ziehen vor dem Tausch der Sicherungen Die Sicherungen 14 befinden sich hinter...

Page 41: ...fgrund der hohen Tiefensch rfe selten n tig ja ja in der Gr e der Aufnahmefl che der Kamera mit 4 3 16 9 Umschaltung ja ja ja via USB seriellem RS232 oder Ethernet LAN Anschluss 2 Telezoom Linsen 64x...

Page 42: ...vor dem Transport des Decken Visualizers dass dieser wie unten abgebildet verpackt wurde Dies ist sehr wichtig um eine Besch digung empfindlicher Teile durch den Transport zu verhindern 20 WICHTIG Ve...

Page 43: ...n freien Bildspeicher 1 9 gespeichert Wenn alle Speicherpl tze belegt sind erscheint eine Meldung auf dem Bildschirm On Screen Men aktivieren Durch Dr cken der MENU Taste 40 f r 1 Sekunde Autofokus au...

Page 44: ...02 Fax 1 650 648 0009 WolfVision Co Ltd Nissho Higashi Nakano Bldg 2F 2 1 6 Higashi Nakano Nakano ku Tokyo 164 0003 Japan Tel 81 0 3 3360 3231 Fax 81 0 3 3360 3236 E mail wolfvision japan wolfvision c...

Reviews: