background image

 

 

Ceiling Tile 

 

Ceiling Tile 

 

EYE Series Mounting Kit 

Part 2: Sheetrock Installation Guide 

 

This lightweight mounting bracket is designed to support the WolfVision EYE Series models above sheetrock 
ceilings. A safety cable anchor point is provided to secure the unit to the building structure. It is the 
responsibility of the installer to ensure this product is properly supported and meets all local building codes 
and plenum requirements. Make sure the ceiling structure is capable of holding at least 12 lbs. (4x the 
combined weight of the mount and camera).   

 
 

 

 

Steps: 

 

Inspect Installation Location 

1)

Determine mounting location ceiling based 
upon the center of the desired focal point  
on the working surface. 

A minimum of 8 

1

/

2

’’ clearance above 

ceiling is required. 

 

Center of installation must be at least 3 

11

/

16

’’ from structural members in ceiling 

to allow for hole clearance.  

 

II 

Assemble Unit 

 

2) 

 

 

A

 

Camera Bracket 

 

 

B

 

Trim Mounting Screw 

 

 

C

 

Mounting Tab 

 

 

D

 

Mounting Screw  

 

 

E

 

Mounting Screw 

 

 

 

(Not used in sheetrock installation) 

 

 

F

 

Rail Clamp Screw 

 

 

G

 

Alignment Ring Nut 

 

 

(Optional) Light Mask 

3)        Using Mounting Screw (

E

), attach Camera 

 

Bracket (

A

) to circular plate.   

 
Note:  For installations using optional lenses, 

longer brackets are available for purchase. 

C

 

Sheetrock 

Summary of Contents for EYE Series

Page 1: ...0 Ceiling Tile WolfVision Support 2055 Sugarloaf Circle Suite 125 Duluth GA 30097 877 873 WOLF support wolfvision us Ceiling Tile Installations Part 1 Sheetrock Installations Part 2...

Page 2: ...cture is capable of holding at least 12 lbs 4x the combined weight of the mount and camera Steps I Inspect Installation Location 1 Determine mounting location within T grid ceiling based upon the cent...

Page 3: ...circular plate Note For installations using optional lenses longer brackets are available for purchase 5 Slide circular plate into mounting assembly 6 Secure circular plate into mounting assembly usi...

Page 4: ...fter assembly is in place insert the two Rail Clamp Screws F 8 Loosen frame screws 9 Install camera into the assembly tighten 20 knurled screws supplied with camera Note It is recommended that the len...

Page 5: ...line to the ceiling tile and mark the center point where the camera will mount 11 At this point you are ready to cut the hole Be sure you have checked the clearances side to side and above the tile A...

Page 6: ...ure assembly by tightening the Frame Screws onto the grid and tightening the Rail Clamp Screws F Note If you need to change the orientation of the image to match the architectural specifications of th...

Page 7: ...ach safety cable to building structure Safety cable not included 16 Loosen knurled screws and lower camera until flush with bottom of ceiling tile A straight edge may be used to verify 17 Attach align...

Page 8: ...the adhesive backing from the Light Mask H Use the four screws B to align the mask properly and adhere to rear of trim ring Note The Light mask H is optional It may be used to block light and or airfl...

Page 9: ...e mount and camera Steps I Inspect Installation Location 1 Determine mounting location ceiling based upon the center of the desired focal point on the working surface A minimum of 8 1 2 clearance abov...

Page 10: ...ting Tabs C and Mounting Screws D Note Use the center hole of the Mounting Tab C Countersunk screw hole is not needed in this step Only 2 Tabs are required You must use the screw holes closest to rail...

Page 11: ...ing 20 knurled screws supplied with camera Note It is recommended that the lens cap be left on for the entire installation process 9 Adjust the camera until the distance from the front of the Mounting...

Page 12: ...m line to the ceiling tile and mark the center point where the camera will mount 11 Be sure you have checked the clearances side to side and above the ceiling Cut a 7 3 8 diameter hole The alignment r...

Page 13: ...era at this time 14 Using this anchor point attach safety cable to building structure 15 Carefully insert assembly with all cables attached into the hole 16 Rotate Mounting Tabs outward so they suppor...

Page 14: ...installed 19 Optional Place the four Trim Mounting Screws B though the trim ring Peel back the adhesive backing from the Light Mask H Use the four screws B to align the mask properly and adhere to rea...

Page 15: ...14 Ceiling Tile Final Product Note Screws must go into the holes designated by these arrows Trim Mounting Screws Trim Mounting Screws 7 Sheetrock...

Page 16: ...15 Ceiling Tile WolfVision Support 2055 Sugarloaf Circle Suite 125 Duluth GA 30097 877 873 WOLF support wolfvision us...

Reviews: