background image

Basic Rules for Safety 

 

USE 

 

The infraNOMIC Heating Panels are designed only for use as heaters and are suitable for installation on Walls 
or Ceilings in domestic or commercial rooms which are suitable for their installation. To use these heaters 
correctly it is necessary to follow the guidelines and instructions laid down in this document. 
 
DO NOT use the heaters in rooms that are open to the elements and/or rooms which could be subjected to the 
ingress of running water. 

 

Danger for Children and Persons with disabilities 

 

-  These products are not to be installed by people (including children) who are physically or mentally 

handicapped, unless a competent person who can provide help and instruction is present. 

Be sure that children do not play with or use the heaters as a toy. 

Make sure that the packing material is kept away from babies and small children as suffocation can result if 
placed over their mouths or noses. 

 

Electrical Safety 

 

Connect and run the heater according to the advice given on the specification plate on the rear of the heater. 
Only connect the heater to a 230 / 240 V AC supply grid. 

Check each heater for damage before installation. Make sure that the heater itself; its plug and cable are free 
of any visible signs of damage. 

ATTENTION: The Heating Panels should 

not

 be used, if the Glass or Ceramic backing is damaged. If 

damage is noticed, immediately disconnect the Panel from the Power supply and contact our Service 
department. 

Do not pull, clamp or in any other way damage the connecting cable attached to the Panel. 

If the attached connecting cable does appear to be damaged please refer to the manufacturer or his service 
department or a similarly qualified person to undertake any repair work. 

Do 

not

 attempt to carry out any repairs, changes or modifications to the Heating Panel. 

Before any assembly or cleaning work is carried out, disconnect the Panel from the electrical power. 

Do 

not

 immerse the Heating Panel in water or splash water onto it! 

When installing the Panel in any form of wet room, it and its cabling should be situated well out of reach of 
any person using the shower or bath. Do 

not

 install the Panel in close proximity of a bath, shower or 

swimming pool. 

The installation of these panels in wet rooms should always be carried out by competent electricians who are 
completely aware of the specifications for installing electrical equipment in these types of room according to 
their own countries laws and standards. 

 

Product Safety Notes 

 

ATTENTION: To insure that the Heating Panel does not overheat, it should not be covered in any way. 

The Panel should not be installed directly under a plug socket. 

Do 

not

 rest anything against, or use the Heating panel to dry clothes and/or stick anything onto its surface. 

Make sure that all local objects in the immediate vicinity of the heater are a minimum of 50 cm away from the 
front and sides of the panel and 10 cm away when objects are above. 

Make sure when installing the Panel that the minimum distance of 2 cm between the Wall or Ceiling and the 
Panel is adhered too. This distance insures that enough space is available for air circulation. 

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 

Summary of Contents for infraNOMIC

Page 1: ...infraNOMIC INFRARED HEATING PANELS Operating and Installation Instructions Installation Instructions only for Framed Panels Wolff Meier GmbH Co KG Glaswerke Am Wingert 16 35428 Langgöns Germany ...

Page 2: ... make sure that you use the heater exactly as per the following instructions the adherence to these instructions is a pre condition to the manufactures liability regarding any guarantee cases After completion please store these instructions in a safe place so that they can be used again if necessary and also can be given to another user if the panel changes hands Contents Thank you for your purcha...

Page 3: ...clamp or in any other way damage the connecting cable attached to the Panel If the attached connecting cable does appear to be damaged please refer to the manufacturer or his service department or a similarly qualified person to undertake any repair work Do not attempt to carry out any repairs changes or modifications to the Heating Panel Before any assembly or cleaning work is carried out disconn...

Page 4: ... A 1 x Accessory Set which includes 2 x Hanging Plates B 4 x Bolts M6 x 8 C 2 x Bolts M6 x 25 D 2 x Hooked Mounting Screws E 2 x Rawl plugs 8mm F 4 x Ring Screws M6 for Ceiling Mounting G 1 x Operating and Installation Handbook If you discover that any parts are missing or are damaged please contact the company where you purchased the product or contact our Service department The Ring Screws G are...

Page 5: ... is 1 7 m long With difficult walls it may be necessary to use special rawl plugs When the Hooked Mounting Screws are screwed into the wall it is important that they are screwed in right up to the flange Wall Installation The Hanging Plates B should be attached to the shorter side of the heating Panel for vertical Installation and on the longer side for a horizontal installation The plates are att...

Page 6: ... Bolts C and Hanging Plates B from the heater Screw the 4 Ring Screws G into the integrated nuts and move these as far as practically possible towards the corners of the frame in a uniform manner These can be then hand tightened Measure the distances between the Ring Screws both from the short and long sides of the frame and transfer these measurements onto the ceiling where the panel is to be ins...

Page 7: ...r consumption of the Heater The power consumption of your heater is included in the information on the nameplate of the heater to be found on the back of the panel Tips for correct use When the Heater is turned on at first it is possible that for a short while you may be aware of a distinct sweet smell This is not harmful to health and if present is caused by the vaporisation of silicon in contact...

Page 8: ...etails of all current models are listed in the Data Page see page 8 The units comply with the test requirements of the European Low Voltage specifications 2006 95 EG and the harmonised Product Standards EN 60335 1 and EN 60335 2 30 and are marked with a CE Conformity Label Guarantee and Service The Heating Panels are guaranteed by Wolff Meier for 2 years after the purchase date If these Operating ...

Page 9: ...0 mm 65 400 9 1 14 5 ca 7 kg ca 5 kg ca 8 kg ca 7 kg 900 x 600 mm 96 500 14 6 21 8 ca 10 kg ca 10 kg ca 11 kg ca 13 kg ca 8 kg 1100 x 600 mm 116 600 21 9 25 9 ca 11 kg ca 11 kg ca 13 kg ca 16 kg ca 10 kg 1200 x 600 mm 126 700 26 34 ca 12 kg ca 12 kg ca 13 kg ca 17 kg ca 11 kg Heating Panel Coloured Type GHE RAL M10 X M24 X HB30 X P RL X SL Power Size of Room to be heated Aluminium Frame 10 mm Alum...