WOLF SW MV: CONTROL BOARD FOR SWING GATES
8
NOTE: WHEN CONNECTING AERIAL ANTENNA, MAKE IT ALWAYS WITHOUT CURRENT.
REGULATIONS
AMPERE-STOP (RED)
DISABLED
POWER (WHITE)
Engine power regulation. Rotate to the LEFT to decrease it and rotate to the RIGHT to
increase it.
SOT STOP (BLUE)
Soft stop motor regulation. Only with Option 7 ON. Rotate to the LEFT to decrease it and
rotate to the RIGHT to inc rease it. Available for opening and closing.
AUTOMATIC CLOSING TIME (GREEN)
Regulates the stand-by time before the automatic closure. Turn to the LEFT to decrease it and to
the RIGHT to increase it.
Minimum 3 seconds.
Maximum 120 seconds.
OPTIONS
1 AUTOMATIC CLOSURE
ON:
Activated. Door closes automatically.
OFF:
Deactivated. Door does not close automatically.
2
DEACTIVATION STOP OPENING
ON:
Door can not stop while opening.
OFF:
Doors stop while opening by pressing the TRANSMITTER, GATE1 or ALTER (15-‐ 16) on board.
3 RADIO PROGRAMMING
ON:
Not allowed.
OFF:
Allowed.
4
INVERSION SHUT
ON:
Before opening, the electro lock and closure relay are activated. At the end of the
closing maneuver tightening time 2 sec for safety.
OFF:
Normal opening with electro lock.
5
OPEN SECURITY CONTACT (CSEG1)