Wolf PWC362418 Planning Information Download Page 8

8

Dimensions in parentheses are in
millimeters unless otherwise specified.

Planning Information

Pro 36"

(914)

Wall Chimney Hood

M O D E L   P W C 3 6 2 4 1 8 ( R )

Pro Wall Chimney Hoods

Model

PWC362418

PWC422418

PWC482418

PWC542418

DF304 / R304 / SRT304

600

600

DF366 / R366 / SRT366 / RT366

900

900

DF364 / R364 / SRT364 / RT364

900

900

RT362

900

900

R488 / RT488

1100

1100

DF486 / R486 / SRT486 / RT486

1100

1100

DF484 / R484 / SRT484 / RT484

1100

1100

Minimum CFM requirements for Wolf ranges and rangetops. Additional CFM may be required for charbroilers, griddles
and long duct runs.

P R O   V E N T I L A T I O N   C F M   R E C O M M E N D A T I O N S

P R O   V E N T I L A T I O N   B L O W E R   O P T I O N S

Pro Wall Chimney Hoods

Blower Description

Blower Number

Wall Chimney Hood Models

600 CFM Internal

CTBLOWER-60INT (801644 – 810314 as of Fall 2007)

PWC362418 / PWC422418

900 CFM Internal

CTBLOWER-90INT (801645 – 810315 as of Fall 2007)

PWC362418 / PWC422418

1200 CFM Internal

IBLOWER-120INT (804703 – 810317 as of Fall 2007)

PWC482418 / PWC542418

1100 CFM In-Line

BLOWER-110IL (808332)

All Pro Wall Chimney Hoods

900 CFM Remote

BLOWER-90REM (801641)

All Pro Wall Chimney Hoods

1200 CFM Remote

BLOWER-120REM (801642)

All Pro Wall Chimney Hoods

1500 CFM Remote

BLOWER-150REM (804701)

All Pro Wall Chimney Hoods

Summary of Contents for PWC362418

Page 1: ...or brass rails are also available to match the bezels of our dual fuel ranges Pro wall chimney ventilation hoods are recommended for use with all Wolf cooking appliances Wolf Pro wall chimney hoods are available in the classic stainless steel finish Rail option hoods R come with a classic stainless steel decorative rail and stand offs Optional platinum or brass rails match dual fuel range bezels P...

Page 2: ...lded seams hemmed edges and sides and hand finished craftsmanship Recessed easy access controls Infinite speed blower control Heat sentry feature automatically turns unit on when heat is sensed and automatically adjusts blower speed Halogen lighting with two settings Removable dishwasher safe restaurant grade stainless steel baffle filters and grease cups Transition with backdraft damper included ...

Page 3: ...ght shell only 78 lbs 35 kg Specifications are subject to change without notice B L O W E R O P T I O N S 600 CFM Internal Blower 801644 as of Fall 2007 801314 900 CFM Internal Blower 801645 as of Fall 2007 801315 1100 CFM In Line Blower 808332 900 CFM Remote Blower 801641 1200 CFM Remote Blower 801642 1500 CFM Remote Blower 804701 Refer to Pro Ventilation Recommendations at the end of this sectio...

Page 4: ...f Hood 36 914 Overall Height of Hood 18 457 Overall Depth of Hood excluding rail 24 610 Countertop to Bottom of Hood 30 762 to 36 914 Location of Electrical Within shaded area See Installation Instructions shipped with unit for detailed specifications I N S T A L L A T I O N S P E C I F I C A T I O N S Dimensions in parentheses are in millimeters unless otherwise specified Planning Information Pro...

Page 5: ...all chimney hoods are shipped without a blower assembly Internal in line or remote blower assemblies are available Blower options also vary with the volume of air that needs to be moved and the length of the duct run Refer to page 8 for Pro Ventilation CFM Recommendations and Blower Options IMPORTANT NOTE Install this ventilation hood only with a Wolf blower Pro wall chimney hoods require a separa...

Page 6: ...ING STRIP WALL HOOD D U C T I N G C O N S I D E R A T I O N S Wolf Pro wall chimney ventilation hoods are shipped without the blower assembly Internal in line and remote blower assemblies are available IMPORTANT NOTE Install this ventilation hood only with a Wolf blower Wolf Pro wall chimney hoods have a vertical discharge location with 10 254 round duct A transition with backdraft damper is inclu...

Page 7: ...owers are mounted inside the hood canopy In line blowers are mounted in between the hood and the exterior of the home Remote blowers can be mounted on the roof or in some cases on an exterior wall Refer to the illustra tions below for dimensions of Wolf in line and remote blowers Pro ventilation recommendation charts on the following page provide minimum CFM recom mendations according to the cooki...

Page 8: ...ddles and long duct runs P R O V E N T I L A T I O N C F M R E C O M M E N D A T I O N S P R O V E N T I L A T I O N B L O W E R O P T I O N S Pro Wall Chimney Hoods Blower Description Blower Number Wall Chimney Hood Models 600 CFM Internal CTBLOWER 60INT 801644 810314 as of Fall 2007 PWC362418 PWC422418 900 CFM Internal CTBLOWER 90INT 801645 810315 as of Fall 2007 PWC362418 PWC422418 1200 CFM Int...