Dimensions in parentheses are in
millimeters unless otherwise specified.

Planning Information

Pro 27"

(686)

Deep Wall Ventilation Hood

M O D E L   P W 6 6 2 7 1 8 ( R )

Ducting for Pro 27" (686)
deep wall hoods.

30" 

TO

 36"

 

(762–914) 

COUNTERTOP 

TO BOTTOM OF 

VENTILATION HOOD 

18" 

(457) 

HEIGHT OF HOOD 

WALL HOOD

DUCTWORK INSTALLATION 

THROUGH ROOF 

 36" 

(914) 

STANDARD 

FLOOR TO 

COUNTERTOP 

HEIGHT 

27" 

(686) 

DEPTH OF HOOD 

 
 

10" 

(254) ROUND DUCT

SOFFIT OR CABINET

OR DUCT COVER  

 

NOTE: HORIZONTAL DISCHARGE REQUIRES AN ACCESSORY KIT.

 

 TRANSITION 

 22

1

/

4

"W x 9"D TO 10" ROUND 

10"H (INCLUDING FLANGES) 

ROOF CAP OR REMOTE BLOWER 

VERTICAL DISCHARGE 

 

D U C T I N G   C O N S I D E R A T I O N S

Wolf Pro 27" (686) deep wall hoods are shipped

without the blower assembly. Internal, in-line

and remote blower assemblies are available. 

IMPORTANT NOTE: 

Install this ventilation hood

only with a Wolf blower.

Pro 27" (686) deep wall hoods have a vertical

discharge. A horizontal discharge kit is available

as a sales accessory.

The hood will operate most efficiently when

ductwork does not exceed 50' (15 m) in length.

Local building codes may require the use of

make-up air. Consult your local HVAC profes-

sional for specific requirements in your area.

IMPORTANT NOTE:

Wolf Pro 27" (686) deep

wall hoods must be vented to the outside. Use

only metal ductwork.

Refer to the illustration below for ducting

considerations for Pro 27" (686) deep wall

hoods.

Summary of Contents for PW662718

Page 1: ...hoods this 27 686 model provides an additional exclusive feature heat lamps Pro wall ventilation hoods are recommended for use with all Wolf cooking appliances For optimal perform ance a Pro 27 686 d...

Page 2: ...des and hand finished craftsmanship Recessed easy access controls Infinite speed blower control Heat sentry feature automatically turns unit on when heat is sensed and automatically adjusts blower spe...

Page 3: ...shell only 160 lbs 73 kg Horizontal discharge applications require a horizontal discharge kit Specifications are subject to change without notice B L O W E R O P T I O N S 1200 CFM Internal Blower 81...

Page 4: ...h of Hood 66 1676 Overall Height of Hood 18 457 Overall Depth of Hood excluding rail 27 686 Countertop to Bottom of Hood 30 762 to 36 914 Location of Electrical Within shaded area See Installation Ins...

Page 5: ...Wolf Pro wall hoods are shipped without a blower assembly Internal in line or remote blower assemblies are available Blower options also vary with the volume of air that needs to be moved and the len...

Page 6: ...CAL DISCHARGE D U C T I N G C O N S I D E R A T I O N S Wolf Pro 27 686 deep wall hoods are shipped without the blower assembly Internal in line and remote blower assemblies are available IMPORTANT NO...

Page 7: ...blowers are mounted in between the hood and the exterior of the home Remote blowers can be mounted on the roof or in some cases on an exterior wall Refer to the illustra tions below for dimensions of...

Page 8: ...n Line BLOWER 110IL 808332 All 27 686 Deep Wall Hoods 600 CFM Remote BLOWER 60REM 801640 PW302718 900 CFM Remote BLOWER 90REM 801641 PW302718 PW362718 PW422718 PW482718 PW542718 1200 CFM Remote BLOWER...

Reviews: