background image

5

Dimensions in parentheses are in
millimeters unless otherwise specified.

Planning Information

Pro Ventilation Hood Liner

M O D E L   P L 5 2 2 2 1 2

I N S T A L L A T I O N N O T E S

Refer to the illustrations and specifications

for overall dimensions and installation specifics.

Wolf Pro ventilation hood liners are recom-

mended for use with any Wolf cooking appli-
ance, and should be as least as wide as the
cooking surface. It is recommended that the
hood overlap the cooking surface by 3" (76) on
either side.

Installation of all Pro hood liners should be

30" (762) to 36" (914) from the bottom of the
decorative hood to the countertop. Follow the
dimensions shown in the Installation
illustration on page 4.

Wolf Pro hood liners are shipped without a

blower assembly. Internal, in-line or remote
blower assemblies are available. Blower options
also vary with the volume of air that needs to
be moved and the length of the duct run. Refer
to the charts at the end of this section for Pro
ventilation recommendations and blower
options.

IMPORTANT NOTE: 

Install this ventilation hood

liner only with a Wolf blower.

Pro hood liners require a separate, grounded

110/120 V AC, 60 Hz power supply. The service
should have its own 15 amp circuit breaker.
Placement of the electrical supply is not critical,
as long as you provide enough 120 V AC, 60 Hz
power cable to make the electrical connection.
Locate electrical within the shaded area shown
in the Installation illustration on page 4.

You must follow all National Electrical Code

regulations. In addition, be aware of local codes
and ordinances when installing your service.

A decorative hood can be created out of

wood, plaster, tile or metal. The shape of the
decorative hood is not critical. The only place
where the liner and outside cover must meet is
at the bottom edge of the metal liner. The deco-
rative hood and liner must fit at the bottom
edge in both width and depth. 

The height of the liner does not have to be

the same as the height of the decorative hood
and is generally shorter.

The top depth of the liner, which is 12" (305)

standard, must be less than the interior depth
of the decorative hood. Measure the interior
depth of the hood at the top height of the liner
to make sure the liner will fit inside the decora-
tive hood.

The hood liner comes standard with a 4"

(102) lower reveal. Be sure to include this
dimension in your decorative hood selection.

Always use the interior measurements of the

decorative hood and measure in multiple places.
Use the smallest dimensions to verify hood liner
specifications. 

Refer to the installation instructions shipped

with each Wolf product for detailed specifica-
tions. This information can also be found on
our website, wolfappliance.com. 

Summary of Contents for PL522212

Page 1: ... liners bring all of the controls lighting and convenience of our Pro ventilation line for those applications with a custom exterior treatment Pro ventilation hood liners are recommended for use with all Wolf cooking appliances Model PL522212 will accommodate a 54 1372 wide decorative hood Wolf Model PL522212 Pro hood liner will accommodate a 54 1372 wide decorative hood Pro hood liners are sold a...

Page 2: ...er control Heat sentry feature automatically turns unit on when heat is sensed and automatically adjusts blower speed Halogen lighting with two settings Removable dishwasher safe restaurant grade stainless steel baffle filters Transition with backdraft damper included UL listed to US and Canadian safety standards Two and five year residential warranty exclusions apply warranty information can be f...

Page 3: ...uirements 110 120 V AC 60 Hz 15 amp dedicated circuit Shipping Weight shell only 76 lbs 34 kg Specifications are subject to change without notice B L O W E R O P T I O N S 1200 CFM Internal Blower 805087 1100 CFM In Line Blower 808332 900 CFM Remote Blower 801641 1200 CFM Remote Blower 801642 1500 CFM Remote Blower 804701 Refer to Pro Ventilation Recommendations at the end of this section A C C E ...

Page 4: ...dth of Liner 523 8 1330 Overall Height of Liner 12 305 Overall Depth of Liner 221 2 572 Countertop to Bottom of Decorative Hood 30 762 to 36 914 Location of Electrical Within shaded area See Installation Instructions shipped with unit for detailed specifications I N S T A L L A T I O N S P E C I F I C A T I O N S Dimensions in parentheses are in millimeters unless otherwise specified Planning Info...

Page 5: ...rical supply is not critical as long as you provide enough 120 V AC 60 Hz power cable to make the electrical connection Locate electrical within the shaded area shown in the Installation illustration on page 4 You must follow all National Electrical Code regulations In addition be aware of local codes and ordinances when installing your service A decorative hood can be created out of wood plaster ...

Page 6: ...F CAP OR REMOTE BLOWER D U C T I N G C O N S I D E R A T I O N S Wolf Pro hood liners are shipped without the blower assembly Internal in line and remote blower assemblies are available IMPORTANT NOTE Install this ventilation hood liner only with a Wolf blower Pro hood liners have a vertical discharge location with 10 254 round duct A transition with backdraft damper is included The hood liner wil...

Page 7: ...blowers are mounted inside the hood liner canopy In line blowers are mounted in between the hood liner and the exterior of the home Remote blowers can be mounted on the roof or in some cases on an exterior wall Refer to the illustrations below for dimensions of Wolf in line and remote blowers Pro ventilation recommendation charts on the following page provide minimum CFM recom mendations according...

Page 8: ...d Liners 900 CFM Remote BLOWER 90REM 801641 All Hood Liners 1200 CFM Remote BLOWER 120REM 801642 All Hood Liners 1500 CFM Remote BLOWER 150REM 804701 All Hood Liners Pro Hood Liners Model PL342212 PL402212 PL462212 PL522212 PL582212 DF304 R304 SRT304 600 600 DF366 R366 SRT366 RT366 900 900 DF364 R364 SRT364 RT364 900 900 RT362 900 900 R488 RT488 1100 1100 DF486 R486 SRT486 RT486 1100 1100 DF484 R4...

Reviews: