background image

Wolf LinkEx

TM

 WF-250XL LED Floodlite

Torque

2.0Nm

3

13

22

2

12

DISPOSAL OF WASTE MATERIAL

Disposal of packaging, LinkEx LED products, old LED panels 

and drivers should be carried out in accordance with national 

regulations, (WEEE).

The Wolf Safety Lamp Co. Ltd has a policy of continuous product 

improvement. Changes in design details may be made without 

prior notice. Prices and design are subject to alteration without 

notice. All products sold are subject to our conditions of sale. 

A copy of these instructions with any relevant revisions can be 

found at www.wolfsafety.com.

CHANGING LED DRIVERS

Unscrew the internal & external wiring terminations from the 

six & two way terminal blocks and remove the driver retention 

bracket by unscrewing the two bolts. To reassemble follow the 

above points in reverse order. For wiring and termination details, 

see Fig. 1-6. Specified torque settings must be followed.

CHANGING GLASS LENS

Replace the glass by unscrewing the six socket head screws 

securing the three retaining plates. Fit the new glass making 

sure strip gasket material is fitted between the glass and each 

retention plate. See Fig. 14. Specified torque settings must be 

followed.

FAULT FINDING

If a WF-250XL Floodlite fails to function, remove the product 

from service into a non hazardous area. Remove the cover and 

apply power to the Floodlite. Check the input voltage at the 

terminals is present and is the correct rating for the Floodlite. 

If the voltage is correct check the output voltage to the LED 

panels, this should be 19V DC+/-1V. If this voltage is not present 

then the driver is faulty, if it is then the LED panel is faulty. 

Replace as necessary.

Risk of Shock

CHANGING LED PANELS

The LED panel can be removed by unscrewing four socket head 

screws and the wiring terminations. Discard the old panel and 

replace with a new one by following the removal procedure in 

reverse. A new thermal pad must be fitted on replacement under 

the LED panel as shown in Fig. 7. For wiring and termination 

details, see Fig. 1-6. Specified torque settings must be followed.

CHANGING CABLE OR SOCKET

Disconnect the input cable, release cable from input gland. 

Check the gland seal is in good condition, fit the new part(s) and 

re-assemble the product by following the stated procedure in 

reverse order. For wiring and termination details, see Fig. 1-6. 

Specified torque settings must be followed.

If any change is made to cable, glands, plugs or sockets the 

manufacturers instructions should be adhehered to, ensuring 

the seal between the item and the cable is reliable.

Please note sockets and plugs have no IP rating unless 

connected or sockets have covers closed.

FRONT COVER

Remove the front cover by unscrewing the four socket head 

retaining bolts. Release the Earth connecting wire by releasing 

the locking spade connnection in the floodlite by depressing the 

tab on the connector and pulling away. See fig. 8.

Perform repairs/maintenance as necessary. To reassemble 

follow the above points in reverse order. Take care not to trap/

crush wires and ensure the seal is in good condition. Ensure 

correct torque settings are followed, as specified in Fig. 7.

*The Certificate label and serial number are fitted to the front 

cover, therefore do not interchange the front covers with other 

WF-250XL Floodlites. See internal body label for serial number 

reference.

Torque

0.5-0.6Nm

Torque

3.6-3.8Nm

4

5

/

8

7

10

11

/

9

Fig. 14

Fig. 15

MAINTENANCE

1. 

IMPORTANT.

 Any maintenance work should be carried out in 

the safe area by suitably qualified and experienced technicians 

only.

2. Isolate the Floodlite from the mains supply and allow to cool 

before carrying out any maintenance work.

3. 

IMPORTANT.

 No modifications are permitted to the Floodlites, 

all spare parts must be purchased from the manufacturer, 

unauthorized modifications or spare parts will invalidate 

certification.

4. Portable Appliance testing must be carried out to IEC, EN 

standards to the correct rating i.e. 250V DC for 18-50V versions 

and 500V DC for 90-264VAC versions. Live and neutral cables 

must be shorted together and the voltage applied between earth 

and this connection.

TECHNICAL DATA

Enclosure

Marine grade aluminium alloy

with a powder coated finish.

Lens

6mm Toughened Glass

Light 

Source

Type

18 x White High Power LEDs

Life

100,000+ hrs

Weight

5.4kg (excluding cable)

ELECTRICAL DATA

Model

WF-250XLL

WF-250XLH

Voltage

18-50V AC/DC

90-264V AC only

Freq Hz

50/60

50/60

Total Circuit Power

≤ 

28 Watts

 31 Watts

VA (AC)

42VA at 24V AC

48VA at 42V AC

52VA at 48V AC

N/A

PHOTOBIOLOGICAL SAFETY

Floodlites are risk group 1 - No photobiological hazard under 

normal behavioural limitations.

EN IEC 60079-17

Reviews: