![Wolf KG 100 Installation And Maintenance Instructions Manual Download Page 20](http://html.mh-extra.com/html/wolf/kg-100/kg-100_installation-and-maintenance-instructions-manual_991715020.webp)
20
Gigant
Wolf GmbH · 84048 Mainburg · Postfach 1380 · Telefon 08751/74-0 · Telefax 08751/741600
EC DECLARATION OF CONFORMITY
Wolf GmbH
Industriestraße 1
D-84048 Mainburg
Germany
We hereby declare that on account of their design and construction and in the versions placed in circulation by us, the
machines listed below are in compliance with the applicable basic health and safety requirements of the EC Directive.
Modifications to the machines undertaken without our prior consent void this Declaration of Conformity.
Designation
Airconditioning units for indoor installation
of equipment:
Airconditioning units for outdoor installation
Airconditioning units with indirectly fired air heater
Type
KG
designation:
KGW
KG/WO
Applicable
EC Machinery Directive
89/293/EEC as amended 93/44/EEC
EC directives
EC Explosion-Protection
94/9/EC (explosion-proof devices)
Directive
Applied
DIN EN 292 Part 1 and 2
Safety of machines – Basic terms, general design
harmonised
principles
standards:
DIN EN 294
Safety distances to prevent upper limbs from touching
danger points
DIN EN 349
Safety of machines – Minimum distances to prevent
crushing of body parts
DIN EN 418
Safety of machines – EMERGENCY STOP device
Applied
DIN 31001 Part 1
Protection devices
national
DIN VDE 0700 Part 1
Safety of electric equipment (IEC 335-1)
standards, e.g.
BG Chemie explosion
(explosion-proof devices)
protection guideline
VDMA 24169 Part 1
Structural measures for explosion protection in fans
(explosion-proof devices)
We hereby declare that the electrical equipment for Wolf airconditioning units type KG, KGW and KG/WO including
the special control cabinets for said products and the control accessories:
room thermostats, room-thermostat timers, remote-control units, actuating motors, valves, valve drives, channel
sensors, room-temperature sensors, room-temperature sensors with setpoint generators, antifreeze thermostats,
remote setpoint generators, differential-pressure sensors, safety temperature monitors, double safety thermostats
airflow monitors, repair switches, auxiliary switches, mixer motors, mixers, pumps and motors
are in compliance with the following guidelines, standards and directives:
Low Voltage Directive:
73 / 23 / EWG
EMC Directives:
89 / 336 / EWG
EN 50081-1
EN 50082-2
Product standards:
EN 60730
Mainburg, 16.10.2000
Norbert Gruber