Wolf IF15 Installation Manual Download Page 4

Fryer Module Specifications

4

1

/

2

"

(13)

SIDES

1"

(25)

FRONT / BACK

7

1

/

2

"

(191)

6"

(152)

DRAIN

OUTLET

21"

(533)

15"

(381)

Overall Dimensions

FRYER MODULE

Installation Specifications

IMPORTANT NOTE:

Installation of the Wolf electric fryer

module must meet minimum clearance requirements

shown in the installation illustration on page 6.

The Wolf fryer module is intended for indoor use. It is

designed to fit a standard 24" (610) deep base cabinet

with 25" (635) deep countertop. Before making the coun-

tertop cut-out, verify that the module will clear the side

walls of the base cabinet.

It is recommended that you use a Wolf cooktop ventilation

hood, pro hood or hood liner with the fryer module. Refer

to the Wolf design guide.

IMPORTANT NOTE:

Wolf does not recommend the use of

downdraft ventilation with the fryer module.

MANUAL DRAIN OUTLET

IMPORTANT NOTE:

The fryer module must be installed in

a base cabinet that allows access to the manual drain

valve for draining the oil. A heat-resistant bucket must be

positioned under the drain outlet to accept the oil. The

bucket must have a minimum 2 gallon (7.6 L) capacity.

Refer to the installation illustration on page 6 for location

of the manual drain outlet.

Failure to locate the fryer module without the proper

clearances will result in a fire hazard.

Summary of Contents for IF15

Page 1: ...INSTALLATION GUIDE Fryer Module ...

Page 2: ...y occur if instructions are not followed WARNING states a hazard that may cause serious injury or death if precautions are not followed Contents Wolf Fryer Module 3 Fryer Module Specifications 4 Fryer Module Installation 8 Service Information 10 Features and specifications are subject to change at any time without notice Visit wolfappliance com specs for the most up to date information IMPORTANT N...

Page 3: ...rical Codes as well as all state municipal and local codes The correct voltage frequency and amperage must be supplied to the appliance from a dedi cated grounded circuit which is protected by a properly sized circuit breaker or time delay fuse The proper voltage frequency and amperage ratings are listed on the product rating plate Record the model and serial numbers before installing the fryer mo...

Page 4: ...lls of the base cabinet It is recommended that you use a Wolf cooktop ventilation hood pro hood or hood liner with the fryer module Refer to the Wolf design guide IMPORTANT NOTE Wolf does not recommend the use of downdraft ventilation with the fryer module MANUAL DRAIN OUTLET IMPORTANT NOTE The fryer module must be installed in a base cabinet that allows access to the manual drain valve for draini...

Page 5: ...onnector manufacturer s recommended procedure carefully Improper connection can result in a fire hazard Electrical Requirements Verify that power is disconnected from the electrical box before proceeding The Wolf electric fryer module requires a separate grounded 3 wire electrical supply with its own circuit breaker Locate the electrical supply within the shaded area shown in the installation illu...

Page 6: ... OUT DEPTH 21 2 64 min 7 178 TO COMBUSTIBLE 7 178 TO COMBUSTIBLE SIDE CABINET 13 330 max Minimum clearance from cooktop cut out to combustible materials up to 18 457 above countertop NOTE Fryer module must be installed in base cabinet with access to valve at bottom of unit to drain oil into heat resistant receptacle Application shown allows for installation of two 15 381 modules side by side 18 45...

Page 7: ...ps or modules are installed together an integrated module filler strip is recommended The filler strip and other accessories are available through your authorized Wolf dealer To obtain local dealer informa tion visit the find a showroom section of our website wolfappliance com IMPORTANT NOTE Review specific installation instruc tions for product to product capabilities Multiple Cooktops COUNTERTOP...

Page 8: ...ning lift the entire unit up from the opening to prevent scratching the countertop Apply the foam strip included in the hardware package to the underside of the module frame Refer to the illustra tion below Reinsert the fryer module into the countertop opening Align the rear edge of the module frame with the pencil line and check that it is parallel to the front edge of the countertop Lift the ent...

Page 9: ...ess Refer to care recommendations in the use care guide Never operate the fryer module without oil damage to the unit may result Oil must be added to the fryer basin before turning the module on Module Removal IMPORTANT NOTE Removal of the fryer module should only be performed by a Wolf authorized service center technician If removing the fryer module is necessary for cleaning or service first dis...

Page 10: ... plate IMPORTANT NOTE Installation and service must be performed by a qualified installer or service agency Warranty service must be performed by a Wolf authorized service center Troubleshooting IMPORTANT NOTE If the fryer module does not operate properly follow these troubleshooting steps Verify that electrical power is being supplied to the module Check the electrical connections to ensure that ...

Page 11: ...ance Inc all rights reserved Wolf Wolf Design Wolf Gourmet W Design and the color red as applied to knobs are registered trademarks and service marks of Wolf Appliance Inc Sub Zero Sub Zero Design Dual Refrigeration Constant Care and The Living Kitchen are registered trademarks and service marks of Sub Zero Inc collectively the Company Marks All other trademarks or registered trademarks are proper...

Page 12: ...WOLF APPLIANCE INC P O BOX 44848 MADISON WI 53744 WOLFAPPLIANCE COM 800 332 9513 816177 REV A 8 2010 ...

Reviews: