background image

Wolf Cooktop Ventilation

65

wolfappliance.com/specs

60 mm

762 mm

230 mm

667 mm

38 mm

DEPTH OF CHIMNEY

Downdrafts

762 mm DOWNDRAFT

914 mm

819 mm

60 mm

230 mm

38 mm

DEPTH OF CHIMNEY

914 mm DOWNDRAFT

1156 mm

1048 mm

60 mm

230 mm

38 mm

DEPTH OF CHIMNEY

1143 mm DOWNDRAFT

Planning Information

Wolf downdraft systems can be used with Wolf electric

and gas cooktops, except unframed models. They can

also be used with some integrated modules but are not

recommended for use with the electric grill, steamer and

fryer modules. A downdraft can also be used with sealed

burner rangetop model ICBSRT304. An accessory trim kit

is necessary for this installation. Contact your Wolf dealer

for details.

IMPORTANT NOTE:

To install a downdraft with a Wolf

cooktop, you must allow for a minimum 638 mm flat

counter space from front to back. A countertop with a

raised lip or backsplash may not allow enough space for

proper installation.

Installation of the remote-mounted control module must

be within 3 m of the downdraft assembly and a minimum

of 102 mm from the outer edge of cooktop element or

burner.

Downdraft models ICBDD30I, ICBDD36I and ICBDD45I

include an 845 m

3

/hr internal blower. Remote blower

assemblies are available for models ICBDD30R,

ICBDD36R and ICBDD45R through your Wolf dealer. For

local distributor information, visit the international section

of our website, wolfappliance.com.

The blower will vary in size and is dictated by the cooking

unit, the volume of air that needs to be moved and the

length of the duct run. Refer to ventilation recommenda-

tions on pages 73–74.

Downdrafts with an internal blower have a 83 mm x 254

mm duct and for remote blower models, a 83 mm x 356

mm duct. All downdrafts have an adjustable discharge.

Consult a qualified HVAC professional for specific installa-

tion and ducting applications.

ELECTRICAL REQUIREMENTS

Wolf downdraft ventilation systems require a separate,

grounded 220-240 V AC, 50/60 Hz power supply. A

grounded 3-prong receptacle should be located within

reach of the .8 m power cord. Certain installations may

require that the electrical supply be placed in an adjacent

cabinet. Maximum total amps for downdraft systems is 3

amps.

Summary of Contents for ICBCT15G/S

Page 1: ...INTERNATIONAL DESIGN GUIDE ...

Page 2: ...ooktops 17 Ranges and Rangetops 42 Cooktop Ventilation 59 Pro Ventilation 67 Shipping Weights 75 Features and specifications are subject to change at any time without notice Visit wolfappliance com specs for the most up to date information ...

Page 3: ...n oven family is a true partner helping to create great meals with ease as well as adding a striking design feature to the kitchen Smart technology gives the E series 10 cooking modes with Wolf s innovative dual convection in single ovens and in the upper unit of double ovens E series ovens can be installed flush with cabinets for a contemporary integrated look New black glass models with tubular ...

Page 4: ...glass model increase dimension by 6 mm 762 mm SINGLE OVENS 603 mm BEHIND FRAME 1280 mm 1257 mm 718 mm 759 mm 603 mm OPEN OVEN DOOR TOP VIEW 67 mm 559 mm 25 mm 48 mm RIGHT SIDE VIEW 759 mm CONDUIT CHANNEL For black glass model increase dimension by 6 mm 244 mm 225 mm 76 mm 762 mm DOUBLE OVENS Interior Specifications INTERIOR CAPACITY L 762 mm Oven 127 INTERIOR DIMENSIONS W H D 762 mm Oven 635 mm 41...

Page 5: ...f usable cabinet depth The cabinet must be able to support 113 kg for a single oven and 181 kg for a double oven The oven has a face trim on all four sides and will overlap stiles and rails Refer to the chart for overlap dimensions Oven Trim Overlap OVEN TRIM E SERIES Top Overlap 16 mm Bottom Overlap 3 mm Side Overlap 19 mm N L1 Single phase wiring diagram 3phase wiring diagram N L1 L2 L3 FLUSH IN...

Page 6: ...91 mm OPENING HEIGHT 610 mm min OPENING DEPTH E 127 mm 102 mm FRONT VIEW SIDE VIEW 1702 mm TYPICAL 1260 mm OPENING HEIGHT E E E 724 mm OPENING WIDTH E 127 mm 102 mm 610 mm min OPENING DEPTH Dimension must accommodate height of oven trim NOTE Location of electrical supply within opening may require additional cabinet depth Dashed line represents profile of unit FRONT VIEW SIDE VIEW 762 mm E Series ...

Page 7: ...T 11 mm PLATFORM SIDE CLEATS 629 mm min FLUSH INSET DEPTH 25 mm For black glass model increase dimension by 6 mm NOTE Platform must support 113 kg Location of electrical supply within opening may require additional cabinet depth Dashed line represents profile of unit FRONT VIEW SIDE VIEW TOP VIEW 25 mm SIDE CLEATS 127 mm 102 mm E E E 762 mm E Series Single Oven FLUSH INSET INSTALLATION ...

Page 8: ...DE CLEATS 629 mm min FLUSH INSET DEPTH 25 mm For black glass model increase dimension by 6 mm NOTE Platform must support 181 kg Location of electrical supply within opening may require additional cabinet depth Dashed line represents profile of unit FRONT VIEW SIDE VIEW TOP VIEW 25 mm SIDE CLEATS 127 mm 102 mm E E E 1702 mm TYPICAL 762 mm E Series Double Oven FLUSH INSET INSTALLATION ...

Page 9: ...ntable support Removable low rack for broiling and removable high rack for baking Oven door with window Multiple rack baking Safety door latches oven will not operate unless the door is closed Oven light comes on when oven is operating or door is open Tight door seals Rear ventilation openings Microwave Ovens Taking the experience we ve gained from our microwave ovens and combining that with the e...

Page 10: ...h a 16 A fuse Planning Information Specifications on the following page provide overall dimensions rough openings and installation options for the convection microwave oven We have minimized the information contained in the illustrations concentrating on the critical information you need to plan your installation Interior Specifications INTERIOR CAPACITY L Convection Microwave with Grill 40 ...

Page 11: ...s Convection Microwave with Grill 462 mm 537 mm 762 mm OVERALL DIMENSIONS FRONT VIEW SIDE VIEW 914 mm FLOOR TO COUNTERTOP 610 mm OPENING DEPTH 730 mm OPENING WIDTH 450 mm OPENING HEIGHT Dashed line represents profile of unit E BUILT IN INSTALLATION ...

Page 12: ... designed to take care of prepared foods until it s time to serve them You can adjust the temperature keeping moist foods moist and crisp foods crisp Warming drawers are ideal for proofing dough Stainless steel drawer fronts are available to match the look of Wolf E series built in ovens and sealed burner rangetops The integrated drawer front allows for a custom wood panel and handle Model ICBWWD3...

Page 13: ... is designed to be installed below a sealed burner rangetop so the panel aligns properly with the front of the rangetop Keep in mind overall dimensions for the warming drawer remain the same even though the drawer front may be wider to match a Wolf 914 mm wide sealed burner rangetop OVERALL DIMENSIONS Dimensions may vary 3 mm Stainless Steel Drawer Front E SERIES A B Tubular Handle 29 mm 89 mm PRO...

Page 14: ...ation instructions are included with the drawer front For all installations the warming drawer must be fully enclosed top and bottom The warming drawer platform must be able to support 91 kg The platform must be a minimum of 25 mm above the toe kick to allow for the warming drawer trim which overlaps 16 mm on all four sides The warming drawer with E series or pro series 25 mm thick front panel can...

Page 15: ...W SIDE VIEW E 610 mm min CABINET DEPTH 727 mm OPENING WIDTH PLATFORM 232 mm OPENING HEIGHT 264 mm 597 mm TYPICAL 914 mm FLOOR TO COUNTERTOP 914 mm RANGETOP OPENING WIDTH 191 mm COOKING SURFACE 216 mm 19 mm PLATFORM NOTE Location of electrical supply within opening may require additional cabinet depth Dashed line represents profile of unit FRONT VIEW SIDE VIEW 914 mm FLOOR TO COUNTERTOP 232 mm OPEN...

Page 16: ... may require additional cabinet depth Dashed line represents profile of unit FRONT VIEW SIDE VIEW 610 mm min CABINET DEPTH 772 mm FLUSH INSET WIDTH 727 mm OPENING WIDTH 22 mm PLATFORM 22 mmTOP AND SIDE CLEATS 914 mm FLOOR TO COUNTERTOP 276 mm FLUSH INSET HEIGHT 232 mm OPENING HEIGHT E E SIDE CLEATS 610 mm min FLUSH INSET DEPTH 25 mm TOP VIEW E Series Pro Series or Integrated Drawer Front FLUSH INS...

Page 17: ...ove the pan The cooktop s surface remains cool Your kitchen stays cooler too Framed induction cooktops have stainless steel trim Unframed models have no trim and can be mounted flush with the countertop KEY FEATURES Ceran glass ceramic surface for scratch resistance and easy cleaning True simmer on select elements prevents scorching Melt setting on select elements for gentle heat Induction element...

Page 18: ...NDUIT 914 mm FRAMED 762 mm 32 mm 22 mm ALL SIDES 533 mm 76 mm CONDUIT 762 mm UNFRAMED 914 mm 76 mm 32 mm 22 mm ALL SIDES CONDUIT 533 mm 914 mm UNFRAMED Heating Zone Diameter and Power Watts 381 mm INDUCTION COOKTOP 220 mm 1800 3000 boost 171 mm 1200 762 mm INDUCTION COOKTOP 220 mm 2 1800 3000 boost 171 mm 1200 140 mm 1200 914 mm INDUCTION COOKTOP 280 mm 3000 4000 boost 220 mm 2 1800 3000 boost 171...

Page 19: ...tops are available in unframed and framed models with the framed models offered in all three stainless steel trims Unframed models can be mounted flush with the countertop KEY FEATURES Ceran glass ceramic surface for scratch resistance and easy cleaning True simmer on select elements prevents scorching Melt setting on select elements for gentle heat Dual and triple heating zones to customize heat ...

Page 20: ...AMED 914 mm 108 mm 22 mm ALL SIDES 533 mm 914 mm UNFRAMED Maximum Element Power Watts 381 mm ELECTRIC COOKTOP 254 mm Triple 900 1800 2500 165 mm Single 1200 762 mm ELECTRIC COOKTOP 254 mm Triple 900 1800 2500 2 203 mm Single 1800 165 mm Single 1200 Singles with Bridge 203 mm x 432 mm 4400 914 mm ELECTRIC COOKTOP 305 mm Triple 1050 2200 2700 229 mm Dual 700 2200 2 203 mm Single 1800 165 mm Single 1...

Page 21: ...nframed induction and electric cooktops can be mounted flush with the top of the countertop or as a frameless installation sitting on top of the countertop surface In either installation the cooktop cut out dimen sions are the same If the cooktop is to be mounted flush with the countertop a recessed area surrounding the cooktop cut out must be provided Wolf downdraft systems cannot be used with un...

Page 22: ...ements IMPORTANT NOTE Be aware of local codes and ordi nances when installing your service 381 mm INDUCTION COOKTOPS Required power supply Single phase 220 240V AC 50 60 Hz 3phase 380 410V AC 50 60 Hz Maximum connected load Single phase 3 6 kW 3phase 3 6 kW Total amps Single phase 16 amps 3phase 16 amps 762 mm INDUCTION COOKTOPS Required power supply Single phase 220 240V AC 50 60 Hz 3phase 380 41...

Page 23: ... terminal box on the unit Electric Cooktop Electrical Requirements IMPORTANT NOTE Be aware of local codes and ordi nances when installing your service 381 mm ELECTRIC COOKTOPS Required power supply Single phase 220 240V AC 50 60 Hz Maximum connected load Single phase 3 7 kW Total amps Single phase 16 amps 762 mm ELECTRIC COOKTOPS Required power supply Single phase 220 240V AC 50 60 Hz Maximum conn...

Page 24: ...OP CUT OUT FRONT 489 mm CUT OUT DEPTH 64 mm min 51 mm TO COMBUSTIBLE 51 mm TO COMBUSTIBLE 51 mm SIDE CABINET 330 mm max Minimum clearance from cooktop cut out to combustible materials up to 457 mm above countertop NOTE Application shown allows for installation of two 381 mm modules side by side E 381 mm 381 mm 114 mm 457 mm min 381 mm Framed Cooktop STANDARD INSTALLATION ...

Page 25: ...E SEE COUNTERTOP CUT OUT BELOW 51 mm TO COMBUSTIBLE 51 mm TO COMBUSTIBLE 51 mm SIDE CABINET 330 mm max 721 mm CUT OUT WIDTH COUNTERTOP CUT OUT FRONT 489 mm CUT OUT DEPTH 64 mm min Minimum clearance from cooktop cut out to combustible materials up to 457 mm above countertop NOTE Electrical location applies only to installation with built in oven 762 mm Framed Cooktop STANDARD INSTALLATION ...

Page 26: ...RTOP CUT OUT BELOW 873 mm CUT OUT WIDTH COUNTERTOP CUT OUT FRONT 489 mm CUT OUT DEPTH 64 mm min 51 mm TO COMBUSTIBLE 51 mm TO COMBUSTIBLE 51 mm SIDE CABINET 330 mm max Minimum clearance from cooktop cut out to combustible materials up to 457 mm above countertop NOTE Electrical location applies only to installation with built in oven 914 mm Framed Cooktop STANDARD INSTALLATION ...

Page 27: ...USH INSTALLATION FRONT 492 mm CUT OUT DEPTH 62 mmmin 537 mm RECESS FOR FLUSH INSTALLATION 40 mm 51 mm TO COMBUSTIBLE 51 mm TO COMBUSTIBLE 51 mm SIDE CABINET 330 mm max Minimum clearance from cooktop cut out to combustible materials up to 457 mm above countertop NOTE Electrical location applies only to installation with built in oven 8 mm 22 mm max COUNTERTOP PROFILE 33 mm RADIUS 11 mm RADIUS 765 m...

Page 28: ...TION FRONT 492 mm CUT OUT DEPTH 62 mmmin 537 mm RECESS FOR FLUSH INSTALLATION 40 mm 51 mm TO COMBUSTIBLE 51 mm TO COMBUSTIBLE 51 mm SIDE CABINET 330 mm max Minimum clearance from cooktop cut out to combustible materials up to 457 mm above countertop NOTE Electrical location applies only to installation with built in oven 8 mm 22 mm max COUNTERTOP PROFILE 33 mm RADIUS 11 mm RADIUS 918 mm RECESS FOR...

Page 29: ...s without boiling or scorching Sealed burners make sloshes and spills a snap to clean up Gas cooktops are offered in classic stainless steel All models can be ordered as natural or LP gas KEY FEATURES Dual stacked sealed burners for precise control and easy cleanup Flame recognition and automatic reignition for safety and ease of use kW from 1 to 4 9 for tasks from melting to searing 3 8 kW on a 3...

Page 30: ...Wolf Gas Cooktops 30 22 mm ALL SIDES 102 mm 533 mm 381 mm 762 mm 22 mm ALL SIDES 102 mm 533 mm 914 mm 22 mm ALL SIDES 102 mm 533 mm 762 mm COOKTOP 914 mm COOKTOP Gas Cooktops 381 mm COOKTOP ...

Page 31: ...ed 9 m long 13 mm or 19 mm ID flexible metal appliance connector is recommended to connect the cooktop to the gas supply line Wolf gas cooktops are designed to operate on natural gas at 20 mb pressure or LP gas at 37 mb pressure Planning Information For ease of installation Wolf recommends using 838 mm wide cabinets with 762 mm gas cooktops and 991 mm cabinets with 914 mm cooktops Burner Rating kW...

Page 32: ... 64 mm min 178 mm TO COMBUSTIBLE 178 mm TO COMBUSTIBLE SIDE CABINET 330 mm max Minimum clearance from cooktop cut out to combustible materials up to 457 mm above countertop NOTE Application shown allows for installation of two 381 mm modules side by side E 381 mm 381 mm 102 mm 457 mm min 127 mm LOCATION OF GAS AND ELECTRICAL EXTENDS ON FLOOR G 64 mm 381 mm Gas Cooktop STANDARD INSTALLATION ...

Page 33: ...OP CUT OUT BELOW 229 mm TO COMBUSTIBLE 229 mm TO COMBUSTIBLE 64 mm SIDE CABINET 330 mm max 737 mm CUT OUT WIDTH COUNTERTOP CUT OUT FRONT 489 mm CUT OUT DEPTH 64 mm min Minimum clearance from cooktop cut out to combustible materials up to 457 mm above countertop NOTE Gas and electrical location applies only to installation with built in oven G 762 mm Gas Cooktop STANDARD INSTALLATION ...

Page 34: ... BELOW 889 mm CUT OUT WIDTH COUNTERTOP CUT OUT FRONT 489 mm CUT OUT DEPTH 64 mm min 229 mm TO COMBUSTIBLE 229 mm TO COMBUSTIBLE SIDE CABINET 330 mm max Minimum clearance from cooktop cut out to combustible materials up to 457 mm above countertop NOTE Gas and electrical location applies only to installation with built in oven 64 mm 914 mm Gas Cooktop STANDARD INSTALLATION ...

Page 35: ...ATURES Induction cooktop Iron and other magnetic cookware heat instantly while the cooktop surface stays cool Electric cooktop Elements operate with high frequency pulsation technology for consistent heating Electric grill Dual elements ensure precise control in front and rear zones for year round grilling Electric steamer Powerful heating element steam cooks meats vegetables and grains beautifull...

Page 36: ... mm FRONT BACK 191 mm 152 mm DRAIN OUTLET 533 mm 381 mm 191 mm 13 mm SIDES 25 mm FRONT BACK 152 mm DRAIN OUTLET 533 mm 381 mm 13 mm SIDES 25 mm FRONT BACK 127 mm 533 mm 381 mm 22 mm ALL SIDES 96 mm 533 mm 381 mm ELECTRIC COOKTOP 64 mm 32 mm 22 mm ALL SIDES 533 mm 381 mm CONDUIT INDUCTION COOKTOP GAS COOKTOP MULTI FUNCTION COOKTOP ELECTRIC GRILL ELECTRIC STEAMER ...

Page 37: ...ower supply Gas modules require a separate grounded 220 240 V AC 50 60 Hz power supply and a grounded 3 prong receptacle located within reach of the 1 8 m power cord Total amps for the electric cooktop is 16 Total amps for the electric grill steamer and fryer is 12 Total amps for gas and multi function cooktops is less than one When multiple cooktops or modules are installed side by side each unit...

Page 38: ...UT OUT FRONT 489 mm CUT OUT DEPTH 64 mm min 178 mm TO COMBUSTIBLE 178 mm TO COMBUSTIBLE 51 mm SIDE CABINET 330 mm max Minimum clearance from cooktop cut out to combustible materials up to 457 mm above countertop NOTE Application shown allows for installation of two 381 mm modules side by side E 381 mm 381 mm 159 mm 457 mm min Electric Grill STANDARD INSTALLATION ...

Page 39: ...e countertop NOTE Application shown allows for installation of two 381 mm modules side by side 457 mm min 194 mm DRAIN OUTLET 152 mm DRAIN OUTLET DRAIN CONNECTION OPTIONS The 16 mm outlet from the steamer valve will accept a drain hose that must flow downward to and tie into an existing sink drain A separate drain with a freefall may also be installed or a heat resistant receptacle may be placed u...

Page 40: ...ryer module must be installed in base cabinet with access to valve at bottom of unit to drain oil into heat resistant receptacle Application shown allows for installation of two 381 mm modules side by side 457 mm min DRAIN OUTLET Electric Fryer STANDARD INSTALLATION DRAIN CONNECTION The fryer module must be installed in a base cabinet with access to the manual valve at the bottom of the unit to dr...

Page 41: ...CUT OUT DEPTH 64 mm min 178 mm TO COMBUSTIBLE 178 mm TO COMBUSTIBLE SIDE CABINET 330 mm max Minimum clearance from cooktop cut out to combustible materials up to 457 mm above countertop NOTE Application shown allows for installation of two 381 mm modules side by side E 381 mm 381 mm 102 mm 457 mm min 127 mm LOCATION OF GAS AND ELECTRICAL EXTENDS ON FLOOR G 64 mm Multi Function Cooktop STANDARD INS...

Page 42: ...ens large and small become gateways to the exciting new world of dual fuel cooking All models have the classic stainless steel finish and can be ordered in natural or LP gas KEY FEATURES Dual stacked sealed burners for precise control and easy cleanup Patented digital oven control knob Dual convection two fans for even heat distribution Ten cooking modes including the bake stone and dehydration ki...

Page 43: ...ges 43 wolfappliance com specs Dual Fuel Ranges 1527 mm RANGE 1527 mm 1035 mm 127 mm RISER 1165 mm 254 mm RISER 1419 mm 508 mm RISER 1194 mm 699 mm 235 mm 749 mm LEGS AND CASTERS ALLOW FOR HEIGHT ADJUSTMENT UP TO 991 mm 911 mm 937 mm HEIGHT TO COOKING SURFACE 664 mm 635 mm 613 mm 762 mm RANGE 914 mm RANGE 1219 mm RANGE SIDE VIEW ALL RANGES ...

Page 44: ...e with charbroiler or griddle teppan yaki and all 1219 mm and 1524 mm models Follow all minimum clearances to combustible surfaces shown in the installa tion illustration on the following page It is recommended that you use a Wolf pro ventilation hood with the dual fuel range If the range is to be installed without ventilation a 914 mm minimum clear ance 1118 mm for charbroiler from countertop to ...

Page 45: ...not be located within this area For island installation 305 mm minimum clearance back of range to combustible rear wall above countertop 330 mm 457 mm 152 mm 57 mm LOCATION OF GAS AND ELECTRICAL EXTENDS ON FLOOR A 83 mm 254 mm GAS 330 mm ELECTRICAL 937 mm TO COOKING SURFACE W OPENING WIDTH 762 mm TO 914 mm TO BOTTOM OF VENTILATION HOOD G E Installation Dual Fuel Range WIDTH W A 762 mm Range 762 mm...

Page 46: ...eat almost instantly distribute heat more evenly and deliver fast temperature recovery after food is placed on the surface All sealed burner rangetop models have the classic stainless steel finish and can be ordered in natural or LP gas KEY FEATURES CONFIGURATIONS 762 mm Dual stacked sealed burners for precise control and easy cleanup Optional configurations including infrared charbroiler griddle ...

Page 47: ... Rangetops 759 mm 216 mm TO COOKING SURFACE 911 mm 216 mm TO COOKING SURFACE 1219 mm RANGETOP 1216 mm 616 mm 318 mm 127 mm RISER 445 mm 254 mm RISER 699 mm 508 mm RISER 724 mm 216 mm TO COOKING SURFACE 191 mm 235 mm 914 mm RANGETOP SIDE VIEW ALL RANGETOPS 762 mm RANGETOP ...

Page 48: ...for a 914 mm rangetop and 136 kg for a 1219 mm rangetop The platform must include a cut out at the right rear for gas supply and electrical connections IMPORTANT NOTE When installing against a combustible surface a minimum 254 mm riser is required for 914 mm and 1219 mm sealed burner rangetops with a charbroiler or griddle teppan yaki Follow all minimum clearances to combustible surfaces shown in ...

Page 49: ...ntertop to combustible materials without ventilation hood NOTE For island installations 305 mm minimum clearance from back of rangetop to combustible rear wall above countertop 152 mm TO COMBUSTIBLE 152 mm TO COMBUSTIBLE 457 mm min 914 mm FLOOR TO COUNTERTOP 406 mm PLATFORM TOP VIEW E G 406 mm 102 mm BACK WALL GAS AND ELECTRICAL THROUGH BOTTOM OF PLATFORM PLATFORM 330 mm max PLATFORM 191 mm OPENIN...

Page 50: ...ntertop to combustible materials without ventilation hood NOTE For island installations 305 mm minimum clearance from back of rangetop to combustible rear wall above countertop 152 mm TO COMBUSTIBLE 152 mm TO COMBUSTIBLE 457 mm min 914 mm FLOOR TO COUNTERTOP 406 mm PLATFORM TOP VIEW E G 406 mm 102 mm BACK WALL GAS AND ELECTRICAL THROUGH BOTTOM OF PLATFORM PLATFORM 330 mm max PLATFORM 191 mm OPENIN...

Page 51: ...ler from countertop to combustible materials without ventilation hood NOTE For island installations 305 mm minimum clearance from back of rangetop to combustible rear wall above countertop 152 mm TO COMBUSTIBLE 152 mm TO COMBUSTIBLE 457 mm min 914 mm FLOOR TO COUNTERTOP PLATFORM 406 mm GAS AND ELECTRICAL THROUGH BOTTOM OF PLATFORM PLATFORM TOP VIEW E G 406 mm 102 mm BACK WALL 330 mm max PLATFORM 1...

Page 52: ...e 4 4 kW heat for searing Options include infrared griddle teppan yaki and charbroiler All gas ranges have the classic stainless steel finish and can be ordered in natural or LP gas KEY FEATURES Gas convection oven for even heat distribution Dual brass burners delivering 3 to 4 4 kW Infrared broiler with ultrafast preheating Flame recognition and automatic reignition for safety and ease of use Por...

Page 53: ...URFACE 1527 mm RANGE 1219 mm 940 mm HEIGHT TO COOKING SURFACE 1524 mm 914 mm 940 mm HEIGHT TO COOKING SURFACE 64 mm 622 mm 641 mm LEGS AND CASTERS ALLOW 25 mm HEIGHT ADJUSTMENT 1102 mm 1187 mm 254 mm RISER 1441 mm 508 mm RISER 692 mm 235 mm 721 mm 1060 mm 127 mm RISER 914 mm RANGE 1219 mm RANGE SIDE VIEW ALL RANGES 762 mm RANGE ...

Page 54: ...m 473 mm 432 mm 762 mm Oven 610 mm 473 mm 432 mm 914 mm Oven 762 mm 473 mm 432 mm Burner Rating kW kW SURFACE BURNERS HIGH SIMMER 4 6 Burners 4 4 3 OPTIONAL FEATURES NATURAL LP Infrared Charbroiler 4 2 4 2 Infrared Griddle Teppan Yaki 5 3 5 3 OVEN BURNERS 457 mm Oven Burner 5 8 5 8 762 914 mm Oven Burner 7 8 7 8 Infrared Broiler 4 6 4 6 Planning Information Wolf gas ranges come in 762 mm 914 mm 12...

Page 55: ...ertop to combustible materials without ventilation hood NOTE For island installations 305 mm minimum clearance from back of range to combustible rear wall above countertop 152 mm TO COMBUSTIBLE 152 mm TO COMBUSTIBLE 457 mm min 914 mm FLOOR TO COUNTERTOP 305 mm 127 mm G 51 mm 940 mm TO COOKING SURFACE 330 mm max 76 mm LOCATION OF GAS AND ELECTRICAL EXTENDS ON FLOOR SIDE CABINET 305 mm 254 mm E 197 ...

Page 56: ...ertop to combustible materials without ventilation hood NOTE For island installations 305 mm minimum clearance from back of range to combustible rear wall above countertop 152 mm TO COMBUSTIBLE 152 mm TO COMBUSTIBLE 457 mm min 914 mm FLOOR TO COUNTERTOP 305 mm 254 mm 305 mm 127 mm G 51 mm 940 mm TO COOKING SURFACE 330 mm max 76 mm LOCATION OF GAS AND ELECTRICAL EXTENDS ON FLOOR SIDE CABINET E 197 ...

Page 57: ...r from countertop to combustible materials without ventilation hood NOTE For island installations 305 mm minimum clearance from back of range to combustible rear wall above countertop 152 mm TO COMBUSTIBLE 152 mm TO COMBUSTIBLE 457 mm min 914 mm FLOOR TO COUNTERTOP 305 mm 660 mm 305 mm 127 mm G 51 mm E 197 mm 146 mm 940 mm TO COOKING SURFACE 330 mm max 76 mm LOCATION OF GAS AND ELECTRICAL EXTENDS ...

Page 58: ...bustible materials without ventilation hood NOTE For island installations 305 mm minimum clearance from back of range to combustible rear wall above countertop 152 mm TO COMBUSTIBLE 152 mm TO COMBUSTIBLE 457 mm min 914 mm FLOOR TO COUNTERTOP 305 mm 254 mm 305 mm 127 mm G 51 mm 940 mm TO COOKING SURFACE 330 mm max 76 mm LOCATION OF GAS AND ELECTRICAL EXTENDS ON FLOOR SIDE CABINET E 197 mm 146 mm 15...

Page 59: ...matically turn unit off Stainless steel filter cover with dishwasher safe aluminum mesh filter ICBCTEWH30I 762 mm WALL LOW PROFILE HOODS ICBCTEWH36 I 914 mm WALL ICBCTEWH45 I 1143 mm WALL Low Profile Hoods Behind the contemporary lines of the new cooktop low profile hoods there s a lot of hard nosed functional thinking Brilliant halogen lighting illuminates your cooking surface Powerful multi spee...

Page 60: ...on 60 Low Profile Hoods WALL HOODS 581 mm 79 mm 54 mm TO 394 mm 276 mm 308 mm 718 mm TO 1054 mm 1067 mm 549 mm ISLAND HOOD 511 mm 79 mm 149 mm TO 467 mm 276 mm 251 mm 740 mm TO 1054 mm 762 mm 914 mm AND 1143 mm WIDTHS 451 mm ...

Page 61: ... require a remote blower assembly available through your Wolf dealer For local distributor information visit the international section of our website wolfappliance com The blower will vary in size and is dictated by the cooking unit the volume of air that needs to be moved and the length of the duct run Refer to ventilation recommenda tions on pages 73 74 These hoods have an 203 mm round duct with...

Page 62: ... m TO 2 7 m FLOOR TO CEILING HEIGHT 451 mm DEPTH OF HOOD 762 mm 914 mm OR 1143 mm WIDTH OF HOOD 740 mm TO 1054 mm HEIGHT OF HOOD LOCATION OF ELECTRICAL 610 mm TO 762 mm TO COUNTERTOP E 381 mm 127 mm Low Profile Wall Hood INSTALLATION ...

Page 63: ...nce com specs 2 4 m TO 2 7 m FLOOR TO CEILING HEIGHT 549 mm DEPTH OF HOOD 1067 mm WIDTH OF HOOD 718 mm TO 1054 mm HEIGHT OF HOOD 610 mm TO 762 mm TO COUNTERTOP LOCATION OF ELECTRICAL THROUGH TOP OF HOOD Low Profile Island Hood INSTALLATION ...

Page 64: ... cover with dishwasher safe aluminum mesh filter ICBDD30I ICBDD30R 762 mm DOWNDRAFTS ICBDD36I ICBDD36R 914 mm ICBDD45I ICBDD45R 1143 mm Downdraft Ventilation The cooktop downdraft unit rises from the countertop to whisk away odors and smoke into the easy to clean five layer mesh filter and can be lowered beneath the countertop when not in use The control module and top cover are available in class...

Page 65: ... m of the downdraft assembly and a minimum of 102 mm from the outer edge of cooktop element or burner Downdraft models ICBDD30I ICBDD36I and ICBDD45I include an 845 m3 hr internal blower Remote blower assemblies are available for models ICBDD30R ICBDD36R and ICBDD45R through your Wolf dealer For local distributor information visit the international section of our website wolfappliance com The blow...

Page 66: ...T OUT TOP VIEW 745 mm Downdrafts INSTALLATION WITH COOKTOP INSTALLATION WITH SEALED BURNER RANGETOP 762 mm rec FLAT COUNTERTOP 745 mm 191 mm 692 mmmin CABINET DEPTH 181 mm 686 mm OR 838 mm DOWNDRAFT CUT OUT 70 mm 762 mm OR 914 mm WIDTH OF RANGETOP 762 mmrec FLAT COUNTERTOP 610 mm min COUNTERTOP CUT OUT TOP VIEW 76 mmmin TO CONTROL MODULE 483 mm PLATFORM DEPTH 64 mmmin EDGE OF RANGETOP TO WALL Addi...

Page 67: ...y of widths Stainless steel baffle filters and halogen lighting extend the professional look and back it up with pro level performance KEY FEATURES Internal or remote blower options Recessed easy access controls Infinite speed ventilator control Heat sentry to automatically turn unit on when exces sive heat is sensed Easy to clean stainless steel baffle filters Heat lamp receptacles on 686 mm deep...

Page 68: ... 457 mm OVERALL HEIGHT 102 mm 610 mm OVERALL DEPTH 914 mm AND 1219 mm WIDTHS 305 mm 610 mm DEEP WALL HOODS 686 mm OVERALL DEPTH 305 mm 457 mm OVERALL HEIGHT 102 mm 762 mm 914 mm 1067 mm 1219 mm AND 1524 mm WIDTHS 686 mm DEEP WALL HOODS ...

Page 69: ...ANT NOTE For optimal performance in wall hood applications a pro 686 mm deep wall hood is recom mended for use with ranges and rangetops that contain a charbroiler or griddle teppan yaki All pro ventilation hoods are shipped without the blower assembly Internal and remote blowers are available through your Wolf dealer The blower will vary in size and is dictated by the cooking unit the volume of a...

Page 70: ...Wolf Pro Ventilation 70 E 152 mm 127 mm LOCATION OF ELECTRICAL WIDTH OF HOOD 762 mm TO 914 mm TO COUNTERTOP 457 mm HEIGHT OF HOOD 610 mm DEPTH OF HOOD 610 mm Deep Wall Hood INSTALLATION ...

Page 71: ... Pro Ventilation 71 wolfappliance com specs E 152 mm 127 mm LOCATION OF ELECTRICAL WIDTH OF HOOD 762 mm TO 914 mm TO COUNTERTOP 457 mm HEIGHT OF HOOD 686 mm DEPTH OF HOOD 686 mm Deep Wall Hood INSTALLATION ...

Page 72: ... ventilation hoods and downdrafts that do not include a blower assembly an internal or remote blower assembly must be selected to accommodate the cooking appliance m3 hr requirements and homeowner prefer ences Internal and remote blowers are available through your Wolf dealer For local distributor information visit the international section of our website wolfappliance com 622 mm 394 mm 718 mm 527...

Page 73: ...BDF366 ICBDF364C ICBDF364G 1521 ICBDF486C ICBDF486G ICBDF484CG ICBDF484F 1859 ICBDF606CG ICBDF604CF 2535 SEALED BURNER RANGETOPS ICBSRT304 845 845 ICBSRT364C ICBSRT364G 1521 ICBSRT486C ICBSRT486G ICBSRT484CG ICBSRT484F 1521 GAS RANGES ICBR304 845 ICBR364C ICBR364G 1521 ICBR486C ICBR486G ICBR484CG 1859 ICBR606CG 2535 Wolf Product m3 hr Recommendations Downdraft systems are not recommended for use w...

Page 74: ...OWER 813160 813161 813162 CE 900 TI 812307 812308 812309 COOKTOP LOW PROFILE HOODS ICBCTEWH36 DOWNDRAFTS ICBDD30R ICBDD36R ICBDD45R PRO 610 mm WALL HOODS ICBPW362418 ICBPW482418 PRO 686 mm WALL HOODS ICBPW302718 ICBPW362718 ICBPW422718 ICBPW482718 ICBPW602718 Wolf Ventilation Blower Options ...

Page 75: ...file Wall Hood 24 914 mm Low Profile Wall Hood 23 26 1143 mm Low Profile Wall Hood 25 28 1067 mm Low Profile Island Hood 42 DOWNDRAFT VENTILATION 762 mm Downdraft 34 914 mm Downdraft 36 1143 mm Downdraft 39 PRO VENTILATION HOODS 610 mm Deep Wall Hoods 38 67 686 mm Deep Wall Hoods 42 74 Wolf Product Shipping Weights Wolf Wolf Design Wolf Gourmet W Design and the color red as applied to knobs are re...

Page 76: ...WOLF APPLIANCE INC PO BOX 44848 MADISON WI 53744 USA WOLFAPPLIANCE COM IW D G 4 2014 ...