Wolf Cooktop Ventilation
65
wolfappliance.com/specs
60 mm
762 mm
230 mm
667 mm
38 mm
DEPTH OF CHIMNEY
Downdrafts
762 mm DOWNDRAFT
914 mm
819 mm
60 mm
230 mm
38 mm
DEPTH OF CHIMNEY
914 mm DOWNDRAFT
1156 mm
1048 mm
60 mm
230 mm
38 mm
DEPTH OF CHIMNEY
1143 mm DOWNDRAFT
Planning Information
Wolf downdraft systems can be used with Wolf electric
and gas cooktops, except unframed models. They can
also be used with some integrated modules but are not
recommended for use with the electric grill, steamer and
fryer modules. A downdraft can also be used with sealed
burner rangetop model ICBSRT304. An accessory trim kit
is necessary for this installation. Contact your Wolf dealer
for details.
IMPORTANT NOTE:
To install a downdraft with a Wolf
cooktop, you must allow for a minimum 638 mm flat
counter space from front to back. A countertop with a
raised lip or backsplash may not allow enough space for
proper installation.
Installation of the remote-mounted control module must
be within 3 m of the downdraft assembly and a minimum
of 102 mm from the outer edge of cooktop element or
burner.
Downdraft models ICBDD30I, ICBDD36I and ICBDD45I
include an 845 m
3
/hr internal blower. Remote blower
assemblies are available for models ICBDD30R,
ICBDD36R and ICBDD45R through your Wolf dealer. For
local distributor information, visit the international section
of our website, wolfappliance.com.
The blower will vary in size and is dictated by the cooking
unit, the volume of air that needs to be moved and the
length of the duct run. Refer to ventilation recommenda-
tions on pages 73–74.
Downdrafts with an internal blower have a 83 mm x 254
mm duct and for remote blower models, a 83 mm x 356
mm duct. All downdrafts have an adjustable discharge.
Consult a qualified HVAC professional for specific installa-
tion and ducting applications.
ELECTRICAL REQUIREMENTS
Wolf downdraft ventilation systems require a separate,
grounded 220-240 V AC, 50/60 Hz power supply. A
grounded 3-prong receptacle should be located within
reach of the .8 m power cord. Certain installations may
require that the electrical supply be placed in an adjacent
cabinet. Maximum total amps for downdraft systems is 3
amps.