Cooktop Chimney Hood Installation
17
wolfappliance.com/specs
In-Line and Remote Blowers
IN-LINE OR REMOTE BLOWER WIRING
IMPORTANT NOTE:
Refer to installation instructions
provided with the in-line or remote blower assembly for
additional mounting and wiring instructions.
Blower connection at the hood:
1)
Remove the cover from the front of the electrical box.
Remove the electrical box knockout that faces the
hood’s discharge collar.
2)
Disconnect the red and black or white wires using a
flat-blade screwdriver.
3)
Insert 6"
(152)
Romex
®
wire through the knockout
opening. Secure the Romex
®
wire to the electrical box
with an appropriate connector. Use wire connectors or
wire nuts approved by UL or C/UL.
4)
Attach the remote blower wiring where wires were
removed in step 2. Attach white to white, black to red,
and ground to yellow.
5)
Place all wiring connections inside the electrical box
and reinstall the cover. Make sure all wires are secure
and that no wires are pinched between the cover and
electrical box.
IMPORTANT NOTE:
Before turning the power on to the
ventilation hood, make sure the blower is off.