Gas Cooktop (CTG) Series
Gas Cooktop (CTG) Series
Technical Data
6-2
#802985 - Revision E - August, 2011
GAS PRESSURE
N
atural Gas Minimum
Liquid Propane Minimum
Natural Gas and Liquid Propane
Maximum
Gas Supply Line Pressure
Liquid Propane Manifold Pressure, with Standard Orifice
14” WC
Natural Gas Manifold Pressure, with Standard Orifice
7” WC
11” WC
10” WC
5” WC
ORIFICE CHART
Natural Gas 5” WC
Liquid Propane Gas 10” WC
NOTE:
For Natural Gas Units Installed Over 10,250 Feet, Contact the Factory for High Altitude Conversion Kit.
ORIFICE CHART
Description
Stamp No.
Elevation In Feet
Valve, Burner, Large
Orifice, Main, Bypass
61
0 - 10,250
Orifice, Simmer, Bypass
57
0 - 10,250
Valve, Burner, Small
Orifice, Main, Bypass
57
0 - 10,250
Orifice, Simmer, Bypass
54
0 - 10,250
Distribution Ring, Large
Orifice, Simmer
M
0 - 10,250
Distribution Ring, Small
Orifice, Simmer
J
0 - 10,250
Jet Holder, Large
Orifice
161
0 - 10,250
Orifice
*140
0 - 10,250
Jet Holder, Small
Orifice
*140
0 - 10,250
Orifice
*119
0 - 10,250
Description
Stamp No.
Elevation In Feet
Valve, Burner, Large
Orifice, Main, Bypass
46
0 - 8,600
Orifice, Simmer, Bypass
36
0 - 8,600
Valve, Burner, Small
Orifice, Main, Bypass
33
0 - 8,600
Orifice, Simmer, Bypass
33
0 - 8,600
Distribution Ring, Large
Orifice, Simmer Burner
X
0 - 8,600
Distribution Ring, Small
Orifice, Simmer Burner
D
0 - 8,600
Jet Holder, Large
Orifice, Main Burner
104
0 - 8,600
Jet Holder, Small
Orifice, Main Burner
89
0 - 8,600
NOTE:
For LP Gas Units Installed Over 8,600 Feet, Contact the Factory for High Altitude Conversion Kit.