Electrical Requirements

Installation must comply with all applicable electrical codes.

Locate the electrical supply as shown in the illustrations 
on the following pages. A separate circuit servicing only 
this appliance is required. A ground fault circuit interrupter 
(GFCI) is not recommended and may cause interruption of 
operation. Refer to the illustration below for minimum power 
cord plug clearance.

Performance may be compromised if the electrical supply is 
less than 240 volts.

ELECTRICAL REQUIREMENTS

Electrical Supply

grounded, 240/208 VAC, 60 Hz

Service

20 amp dedicated circuit

Receptacle

NEMA 6-20R grounding-type

Power Cord

6'

 (1.8 m)

SPECIFICATIONS

 WARNING

ELECTRICAL SHOCK HAZARD: Plug into a grounded 
3-prong outlet. Do not remove the ground prong. Do 
not use an adapter. Failure to follow these instructions 
can result in electric shock, 

fi

re, or death.

NEMA

PLUG

GROUNDED

NEMA RECEPTACLE

1" 

(25)

MINIMUM

CORD

CLEARANCE

 
NEMA 6-20R receptacle

 
Power cord clearance

 
Rating plate location

 

RATING PLATE

Summary of Contents for CSO30TE/S/TH

Page 1: ...CONVECTI ON STE AM OVE N INSTALLATION GUIDE S P ECIFICATIONS I NSTALLATION AND MORE ...

Page 2: ...where minor injury or product damage may occur if instructions are not followed WARNING states a hazard that may cause serious injury or death if precautions are not followed IMPORTANT NOTE Throughout this guide dimensions in parentheses are millimeters unless otherwise specified IMPORTANT NOTE Save these instructions for the local electrical inspector Sub Zero Sub Zero Design Sub Zero Snowflake D...

Page 3: ...20 Rating plate location RATING PLATE Installation Requirements The convection steam oven can be installed in a standard or flush inset application The electrical supply for the oven must be located in an adjacent cabinet Finish the edges of the opening They may be visible when the door is open For standard installations the face trim overlaps stiles and rails Refer to the chart For flush inset in...

Page 4: ...cord plug clearance Performance may be compromised if the electrical supply is less than 240 volts ELECTRICAL REQUIREMENTS Electrical Supply grounded 240 208 VAC 60 Hz Service 20 amp dedicated circuit Receptacle NEMA 6 20R grounding type Power Cord 6 1 8 m SPECIFICATIONS WARNING ELECTRICAL SHOCK HAZARD Plug into a grounded 3 prong outlet Do not remove the ground prong Do not use an adapter Failure...

Page 5: ...team Oven STANDARD INSTALLATION E FRONT VIEW SIDE VIEW NOTE 24 610 and 30 762 models require the same opening dimensions 17 11 16 449 OPENING HEIGHT 23 584 OPENING DEPTH TOP VIEW W OPENING WIDTH OPENING WIDTH W 24 Model 221 8 562 30 Model 221 8 562 ...

Page 6: ...LUSH INSET WIDTH FRONT VIEW SIDE VIEW 24 610 FLUSH INSET DEPTH 7 8 22 Will be visible and should be finished to match cabinetry Dimension provides minimum reveals 181 8 460 FLUSH INSET HEIGHT 5 16 8 1 8 3 A TOP VIEW FINISHED CLEATS OPENING WIDTH W A 24 Model 233 4 603 13 16 21 30 Model 301 8 765 4 102 ...

Page 7: ...supplied to the oven Verify proper electrical connections If the oven does not operate properly contact Wolf Factory Certified Service Do not attempt to repair the oven Wolf is not responsible for service required to correct a faulty installation INSTALLATION Preparation Before moving the oven protect any finished flooring and secure the oven door closed to prevent damage Use an appliance dolly to...

Reviews: