background image

NOTE:  In line with its policy to continually improve its product, Wolf Range Company

reserves the right to change materials and specifications without notice.

This appliance is manufactured for commercial use only and is not intended for home use.

F-36956 (04-07)

MODEL: AHP  

COUNTER MODEL ACHIEVER HOTPLATE

INSTALLATION REQUIREMENTS:
1.  A gas pressure regulator sized for this unit is included. Natural 

Gas 5.0" W.C. Propane Gas 10.0" W.C.

2.  An adequate ventilation system is required for commercial 

cooking equipment. Information may be obtained by writing 
to the National Fire Protection Association, 1 Batterymarch 
Park, Quicy, MA 02169, www.NFPA.org. When writing refer 
to NFPA No. 96.

3.  These units are manufactured for installation in accordance 

with National Fuel Gas Code, ANSI-Z223.1/NFPA #54 (lat-
est edition). Copies may be obtained from The American 

 

 

 

 

OVERALL 

WORKING 

NO. OF 

TOTAL 

APPROX. SHIP

 

MODEL 

WIDTH 

DEPTH 

HEIGHT 

HEIGHT 

BURNERS 

BTU/HR. 

WT. (LB/KG)

  AHP212 

12" 

 

 

 

60,000 

95 lbs./43 kg

  AHP424 

24" 

 

 

 

120,000 

165 lbs./74 kg

  AHP636 

36" 

33" 

14-5/8" 

12-3/8"

 

180,000 

265 lbs./119 kg

  AHP848 

48" 

 

 

 

240,000 

310 lbs./140 kg

Gas  Association,  Accredited  Standards  Committee  Z223 
@  400N.  Capital  St.  NW,  Washington,  DC  20001,  or  the 
Secretary Standards Council, NFPA, 1 Batterymarch Park, 
Quincy, MA 02169-7471.

 
 

NOTE: In the Commonwealth of Massachusetts

 

All  gas  appliances  vented  through  a  ventilation  hood  or 
exhaust system equipped with a damper or with a power 
means of exhaust shall comply with 248 CMR.

4.  This appliance must be installed with a 6" clearance at both 

sides and the rear adjacent to combustible construction.