All internal packaging has been
removed.

All shipping restraints have been
removed from the burners.

Radiants are oriented properly

over grill burners with triangle
cutout towards back (see below
illustration).

Specified clearances to any
combustible materials have been
maintained.

Batteries are installed to push
button ignitors properly

All burners light properly,
individually and with adjacent
burners lit.

All flames appear normal.

The drip tray slides freely. The
grease collection tray is properly
placed.

The pressure regulator is connect-
ed, and set for 5"(127) WC for
natural gas or 11"(279) for LP gas.

The LP cylinder is in an upright
position and the hose is not
kinked.

The unit has been tested and is
free of leaks.

The user has been informed of the
gas supply shut off valve location.

I

N S T A L L A T I O N

Leak Testing Procedure:

Check that all the control knobs are

in the OFF position.

Mix a half soap and half water solu-

tion.

Turn cylinder valve knob counter-

clockwise one turn to open.

Apply soap /water solution on joints

of the gas delivery system.

Blowing bubbles in the soap solu-

tion indicates that a leak is present.

Stop a leak by tightening the loose

joint or by replacing the faulty part
with a replacement part recommend-
ed by the manufacturer. 

Do not

attempt to repair the cylinder valve if
it should become damaged. The
cylinder must be replaced.

If you are unable to stop a leak,

shut off the gas supply at the cylinder
valve. Remove the cylinder from the
grill. Call an authorized gas appliance
servicer or LP gas dealer. 

Do not

use the appliance until the leak is
corrected.

Push in and turn any control knob

to the on position to release pressure
in the hose and manifold.

Turn OFF the control knob.

L E A K T E S T I N G

Perform a leak test each time the gas
cylinder is connected to the regula-
tor, and any time part of the gas sys-
tem is disconnected or replaced. This
applies to natural gas as well as LP
gas. Perform a leak test at least once
each year whether the LP gas supply
cylinder has been disconnected or
not.

Test for leaks at the cylinder valve,
cylinder welds, regulator (especially
attached to cylinder valves), hose and
connections.

NO SMOKING! Do not

use or permit

sources of ignition in the area while
doing a leak test.

Conduct leak tests outdoors in a well
ventilated area.

Do not

use a flame, such as a lighted

match to test for leaks. Use only a
soap /water solution for leak testing.
(Example: half liquid soap and half
water.)

Have a dealer check the cylinder for
deterioration when the tank is filled
in accordance with regulations.
Immediately replace cylinder if any
deterioration is found.

Testing for gas leakage of the
appliance shall be conducted
according to the manufac-
turer’s instructions.

Do not store a spare LP gas
cylinder under or near this
appliance.

Never fill the cylinder more
than 80% full.

If this information is NOT fol-
lowed exactly, a fire causing
death or serious injury may
occur.

Dimensions in parentheses are in millimeters unless noted.

Radiant positioning

gas bbq grills install 803861 rev-b 3-04.qxp  3/23/2004  9:01 AM  Page 10

Summary of Contents for BBQ242

Page 1: ...G A S B B Q G R I L L S I N S T A L L A T I O N I N S T R U C T I O N S ...

Page 2: ... as all state municipal and local codes The correct voltage frequency and amperage must be supplied to the appliance from a dedicated grounded circuit that is protected by a properly sized circuit breaker or time delay fuse The prop er voltage frequency and amperage ratings are listed on the product rating plate Record the model and serial numbers before installing the BBQ grill Both numbers are l...

Page 3: ...ning according to the Installation Dimensions on page 5 For non combustible masonry or other enclosure also follow the speci fications on page 5 Maintain speci fied clearances Both installations require a deck to support the bottom Review the Installation Dimensions illustrations and provisions required for the gas line hook up at the rear right and bottom surfaces It is recommended that ventilati...

Page 4: ... clearances to a combustible surface must be observed Be cer tain the appliance is properly grounded to avoid shock hazard You must follow all National Electrical Code and gas regulations In addition be aware of local code or ordinances when installing your service Installation Dimensions BBQ242 BBQ36 BBQ362 BBQ48 A Overall Width of Grill 36 914 36 914 48 1219 48 1219 B Width of Hood 24 610 36 914...

Page 5: ... FOR ROTISSERIE ON LEFT SIDE 2 51 DIAMETER OPENING FOR GAS SUPPLY CONNECTION BOTTOM LOCATION 27 8 73 E 361 2 max 927 NON COMBUSTIBLE ENCLOSURE D ROUGH OPENING DEPTH 91 2 242 ROUGH OPENING HEIGHT 6 152 min 6 152 min 41 2 114 min 91 2 242 ROUGH OPENING HEIGHT 21 8 54 21 8 54 23 4 70 2 51 DIAMETER OPENING FOR GAS SUPPLY CONNECTION BACK WALL LOCATION OR BOTTOM LOCATION ALLOW OPENING FOR ACCESS DOOR LO...

Page 6: ...ertain all valves are in a closed position Do not connect the gas supply line to an appliance that shows any sign of physical damage Contact your qualified servicer E L E C T R I C A L R E Q U I R E M E N T S If using a rear wall locate the electri cal service on the left hand side for the rotisserie motor The rotisserie motor requires a 110 120 volt supply The six foot power supply cord on the mo...

Page 7: ...dividual shut off valve must be disconnected from the gas supply piping system during any pressure testing of that system at test pressures greater than 1 2 psig 3 5 kPa Testing below 1 2 psi 3 5 kPa 14 356 mm WC gauge or lower The BBQ grill must be iso lated from the gas supply piping sys tem by closing its individual manual shut off valve during any pressure testing of the gas supply piping sys ...

Page 8: ...verfill cylinder After filling have the gas dealer check for leaks to see that the relief valve remains free to function Approximate running time for the 20 lb LP tank BBQ36 69 000 BTU 6 1 2 hrs BBQ242 80 000 BTU 5 1 2 hrs BBQ48 89 000 BTU 5 hrs BBQ362 101 000 BTU 4 1 2 hrs L P G A S H O O K U P A Wolf BBQ grill set up for use with LP gas comes equipped with a five foot hose regulator and an unfil...

Page 9: ...er and rotisserie if so equipped are in the OFF posi tion Make certain the cylinder valve handwheel is in the closed position Turn clockwise left to right to full stop Remove the protective caps from the cylinder valve and coupling nut Hold the regulator in one hand and insert the nipple into the cylinder valve Be certain the nipple is cen tered in the valve outlet Hand tight en the coupling nut D...

Page 10: ...e to stop a leak shut off the gas supply at the cylinder valve Remove the cylinder from the grill Call an authorized gas appliance servicer or LP gas dealer Do not use the appliance until the leak is corrected Push in and turn any control knob to the on position to release pressure in the hose and manifold Turn OFF the control knob L E A K T E S T I N G Perform a leak test each time the gas cylind...

Page 11: ...ervice Center call Wolf Customer Service at 800 332 9513 or check our website www wolfappliance com When calling for service you will need the BBQ grill model and serial numbers Both numbers are listed on the rating plate located on the back panel of the unit Be certain to disconnect the gas and electric supplies before servicing Surface burners can be lit manually with a match Use extreme caution...

Page 12: ...WOLF APPLIANCE COMPANY LLC P O Box 44848 Madison WI 53744 800 332 9513 www wolfappliance com 803861 REV B 3 04 ...

Reviews: