BLOWER

DUCT CONNECTOR

DUCTING OPTIONS

BLOWER DISCHARGE POSITIONS

Blower and duct connec-

tor in horizontal discharge 

position. (Factory shipped)

DUCT CONNECTOR

Blower and duct connec-

tor in vertical discharge 

position.

BLOWER

Change 

blower

& duct 

connector 

positions

for vertical

discharge.

DUCTING 

(Vertical blower discharge)

Typical ductwork connection to a ventilator converted to 

vertical discharge.

ROOF CAP

10”

ROUND

DUCT

4½” X 18½”

TO 10” ROUND

TRANSITION

WIRING PLATE POSITION

Wiring plate mounts to side or top of housing.

HORIZONTAL POWER 

CABLE CONNECTION

VERTICAL 

POWER CABLE 

CONNECTION

WIRING

WIRING

PLATE

WHITE

TO

WHITE

BLACK

TO

BLACK

TOP / BACK

OF HOUSING

120 VAC

LINE IN

(from

range

hood)

GROUND TO

WIRING PLATE

Ventilator can be wired from outside of housing.

Use UL approved connectors to wire per local codes.

ADUSTABLE FOR VARIOUS CEILING THICKNESSES

21½"

9

1

/

2

" to

10

1

/

2

"

21½"

ADUSTABLE FOR VARIOUS CEILING THICKNESSES

10 

3

/

4

" to

11 

3

/

4

"

MOUNTING OPTIONS

21½"

1

1

/

8

"

MAX.

ADUSTABLE FOR VARIOUS CEILING THICKNESSES

Mounting brackets in 

factory-shipped position. 

(Outlet parallel to joists.)

(New construction)

12¼"

INSTALLATION WITH DUCTWORK

RUNNING ACROSS JOISTS

¼-20 hex nuts secure mounting brackets to housing. Loosen and 

re-tighten or remove and replace nuts as necessary for desired 

mounting bracket position.

Mounting brackets mounted 

to outlet sides of housing.

(Outlet perpendicular to joists.)

(New construction)

Mounting brackets flipped 

over and mounted to top of 

sides of housing.

(Outlet parallel to joists.)

(New or existing construction)

1

1

/

2

"

to

2

1

/

2

"

21½"

ADUSTABLE FOR VARIOUS CEILING THICKNESSES

Mounting brackets flipped 

over to give approx. 1” 

more clearance.

(Outlet parallel to joists.)

(New construction)

Mounting brackets mounted 

to top of sides of housing.

(Outlet parallel to joists.)

(New or existing construction)

INSTALLATION FROM ABOVE FINISHED CEILING

21½"

1½"

to

2½"

Mounting brackets flipped 

over and mounted to outlet 

sides of housing.

(Outlet parallel to joists.)

(Existing construction)

Summary of Contents for 808331

Page 1: ...uzette Cherries Jubilee Peppercorn Beef Flambe 3 Clean ventilating fans frequently Grease should not be allowed to accumulate on fan or filter 4 Use proper pan size Always use cookware appropriate for the size of the surface element TO REDUCETHE RISK OF INJURYTO PERSONS INTHE EVENT OFA RANGETOP GREASE FIRE OBSERVETHE FOLLOWING 1 SMOTHER FLAMES with a close fitting lid cookie sheet or metal tray th...

Page 2: ...tapefromdamper Remove the shipping tape from the damper flap and make sure that damper flap opens and closes freely inside the ductwork Use duct tape to make ductwork connections secure and air tight ACCESS PANEL ACCESS PANEL SCREW GRILLE NUT Install into square holes in housing MOUNTING BRACKET 10 ROUND DUCT OUTLET 10 ROUND DUCT INTAKE HANGER KIT NUT WASHER HANGER KIT BOLT WASHER HANGER KIT EYE B...

Page 3: ...ABLE FOR VARIOUS CEILING THICKNESSES 10 3 4 to 11 3 4 MOUNTING OPTIONS 21 11 8 MAX ADUSTABLE FOR VARIOUS CEILING THICKNESSES Mounting brackets in factory shipped position Outlet parallel to joists New construction 12 INSTALLATION WITH DUCTWORK RUNNING ACROSS JOISTS 20 hex nuts secure mounting brackets to housing Loosen and re tighten or remove and replace nuts as necessary for desired mounting bra...

Page 4: ... discharge area and wheel DO NOT ALLOW WATER TO ENTER MOTOR Make sure blower assembly is completely dry before reinstalling Motor is permanently lubricated Do not oil or disassemble motor USE AND CARE Follow wiring instructions packed with range hood and adhere to all local and state codes and the National Electrical Code ATTACH POWER CORD TO HOOD Some hoods require the use of a separate power cor...

Page 5: ...corn Beef Flambe 3 Clean ventilating fans frequently Grease should not be allowed to accumulate on fan or filter 4 Use proper pan size Always use cookware appropriate for the size of the surface element TO REDUCETHE RISK OF INJURYTO PERSONS INTHE EVENT OFA RANGETOP GREASE FIRE OBSERVETHE FOLLOWING 1 SMOTHER FLAMES with a close fitting lid cookie sheet or metal tray then turn off the burner BE CARE...

Page 6: ...n Factory shipped unit installed in existing construction ACCESS PANEL SCREW Ventilator factory shipped in straight through discharge position MOUNTING BRACKETS CEILING JOIST 24 centers shown ACCESS PANEL GRILLE NUT Install into square holes in housing GRILLE NUT Install into square holes in hous ing IMPORTANT Remove shipping tape from damper Remove the shipping tape from the damper flap and make ...

Page 7: ...ors to wire per local codes 18 1 to 2 18 1 to 2 22 ADUSTABLE FOR VARIOUS CEILING THICKNESSES 22 11 8 MAX ADUSTABLE FOR VARIOUS CEILING THICKNESSES MOUNTING OPTIONS Mounting brackets in factory shipped position mounted directly to joists Outlet parallel to joists New construction 20 hex nuts secure mounting brackets to housing Loosen and re tighten or remove and replace nuts as necessary for desire...

Page 8: ... discharge area and wheel DO NOT ALLOW WATER TO ENTER MOTOR Make sure blower assembly is completely dry before reinstalling Motor is permanently lubricated Do not oil or disassemble motor USE AND CARE Follow wiring instructions packed with range hood and adhere to all local and state codes and the National Electrical Code ATTACH POWER CORD TO HOOD Some hoods require the use of a separate power cor...

Reviews: